메뉴 건너뛰기




Volumn , Issue , 2012, Pages

Conservation Voltage Reduction with feedback from Advanced Metering Infrastructure

Author keywords

Automatic voltage control; Energy conservation; Load management; Meter reading; Power system management; Smart grids

Indexed keywords

ADVANCED METERING INFRASTRUCTURES; AUTOMATIC VOLTAGE CONTROL; CONSERVATION VOLTAGE REDUCTIONS; DEMAND REDUCTION; ELECTRICAL MODELS; END-OF-LINE; LOAD TAP CHANGER; METER READINGS; OPERATIONAL ISSUES; POWER SYSTEM MANAGEMENT; SMART GRID; STATISTICAL EVALUATION; VIRGINIA; VOLTAGE DATA; VOLTAGE FEEDBACK; VOLTAGE MONITORING;

EID: 84867954923     PISSN: 21608555     EISSN: 21608563     Source Type: Conference Proceeding    
DOI: 10.1109/TDC.2012.6281644     Document Type: Conference Paper
Times cited : (50)

References (7)
  • 1
    • 78649542106 scopus 로고    scopus 로고
    • Measurement and verification of distribution voltage optimization results for the IEEE Power & Energy Society
    • T. L. Wilson, "Measurement and verification of distribution voltage optimization results for the IEEE Power & Energy Society, " in Proc. 2010 Power and Energy Society General Meeting, pp. 1-9.
    • Proc. 2010 Power and Energy Society General Meeting , pp. 1-9
    • Wilson, T.L.1
  • 2
    • 84867945147 scopus 로고    scopus 로고
    • Virginia General Assembly. (2006, Jan. 11). HB 3068, Electric utility service; advances scheduled expiration of capped rate period
    • Virginia General Assembly. (2006, Jan. 11). HB 3068, Electric utility service; advances scheduled expiration of capped rate period.
  • 3
    • 84867944425 scopus 로고    scopus 로고
    • Virginia Department of Mines, Minerals and Energy. (2010, Jul.). Virginia Energy Plan
    • Virginia Department of Mines, Minerals and Energy. (2010, Jul.). Virginia Energy Plan.
  • 4
    • 84867924130 scopus 로고    scopus 로고
    • Electric Power Systems and Equipment-Voltage Ratings, ANSI Standard C84.1-2006, Dec. 2006
    • Electric Power Systems and Equipment-Voltage Ratings, ANSI Standard C84.1-2006, Dec. 2006.
  • 5
    • 84867929594 scopus 로고    scopus 로고
    • Cyber Security-Critical Cyber Asset Identification, NERC Standard CIP-002-1, Jun. 2006
    • Cyber Security-Critical Cyber Asset Identification, NERC Standard CIP-002-1, Jun. 2006.
  • 6
    • 0026203135 scopus 로고
    • Conservation voltage reduction (CVR) at snohomish county PUD
    • Aug.
    • B. W. Kennedy and R. H. Fletcher, "Conservation Voltage Reduction (CVR) at Snohomish County PUD, " IEEE Trans. Power Syst., vol. 6, no. 3, pp. 986-998, Aug. 1991.
    • (1991) IEEE Trans. Power Syst. , vol.6 , Issue.3 , pp. 986-998
    • Kennedy, B.W.1    Fletcher, R.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.