메뉴 건너뛰기




Volumn 12, Issue 2, 2012, Pages 387-394

Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours

Author keywords

Focused ultrasound; Interventional oncology; Liver tumour ablation; MR HIFU

Indexed keywords

B SCAN; BONE METASTASIS; CANCER PALLIATIVE THERAPY; CONFERENCE PAPER; ECHOGRAPHY; HIGH INTENSITY FOCUSED ULTRASOUND; HUMAN; LIVER PERFUSION; LIVER TUMOR; MAGNETIC RESONANCE GUIDED HIGH INTENSITY FOCUSED ULTRASOUND ABLATION; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; RADIOFREQUENCY ABLATION; TEMPERATURE; THERMAL DIFFUSION; TUMOR ABLATION; ULTRASOUND THERAPY; UTERUS MYOMA; VOLUMETRY;

EID: 84867910363     PISSN: None     EISSN: 14707330     Source Type: Journal    
DOI: 10.1102/1470-7330.2012.9038     Document Type: Conference Paper
Times cited : (64)

References (59)
  • 1
    • 84859212951 scopus 로고    scopus 로고
    • Hepatocellular carcinoma
    • doi:10.1016/S0140-6736(11)61347-0. PMid:22353262
    • Forner A, Llovet JM, Bruix J. Hepatocellular carcinoma. Lancet 2012; 379: 1245-1255. doi:10.1016/S0140-6736(11)61347-0. PMid:22353262.
    • (2012) Lancet , vol.379 , pp. 1245-1255
    • Forner, A.1    Llovet, J.M.2    Bruix, J.3
  • 2
    • 75749100265 scopus 로고    scopus 로고
    • American Society of Clinical Oncology 2009 clinical evidence review on radiofrequency ablation of hepatic metastases from colorectal cancer
    • doi:10.1200/JCO.2009.23.4450. PMid:19841322
    • Wong SL, Mangu PB, Choti Ma, et al. American Society of Clinical Oncology 2009 clinical evidence review on radiofrequency ablation of hepatic metastases from colorectal cancer. J Clin Oncol 2010; 28: 493-508. doi:10.1200/JCO.2009.23. 4450. PMid:19841322.
    • (2010) J Clin Oncol , vol.28 , pp. 493-508
    • Wong, S.L.1    Mangu, P.B.2    Choti, M.3
  • 3
    • 83555173255 scopus 로고    scopus 로고
    • Mortality and complication rates of percutaneous ablative techniques for the treatment of liver tumors; a systematic review
    • doi:10.1007/s00330-011-2222-3. PMid:21858539
    • Bertot LC, Sato M, Tateishi R, et al. Mortality and complication rates of percutaneous ablative techniques for the treatment of liver tumors; a systematic review. Eur Radiol 2011; 21: 2584-2596. doi:10.1007/s00330-011-2222- 3. PMid:21858539.
    • (2011) Eur Radiol , vol.21 , pp. 2584-2596
    • Bertot, L.C.1    Sato, M.2    Tateishi, R.3
  • 4
    • 37049195387 scopus 로고
    • The biological application of focused ultrasonic waves
    • doi:10.1126/science.96.2483.119. PMid:17809987
    • Lynn JG, Zwemer RL, Chick AJ. The biological application of focused ultrasonic waves. Science 1942; 96: 119-120. doi:10.1126/science.96.2483.119. PMid:17809987.
    • (1942) Science , vol.96 , pp. 119-120
    • Lynn, J.G.1    Zwemer, R.L.2    Chick, A.J.3
  • 5
    • 0029677201 scopus 로고    scopus 로고
    • A clinical, noninvasive, MR imaging-monitored ultrasound surgery method
    • PMid:10946699
    • Hynynen K, Freund R, Chung H, et al. A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. Radiographics 1996; 16: 185-195. PMid:10946699.
    • (1996) Radiographics , vol.16 , pp. 185-195
    • Hynynen, K.1    Freund, R.2    Chung, H.3
  • 6
    • 0027344177 scopus 로고
    • The feasibility of using MRI to monitor and guide noninvasive ultrasound surgery
    • doi:10.1016/0301-5629(93)90022-G. PMid:8456533
    • Hynynen K, Damianou C, Darkazanli A, et al. The feasibility of using MRI to monitor and guide noninvasive ultrasound surgery. Ultrasound Med Biol 1993; 19: 91-92. doi:10.1016/0301-5629(93)90022-G. PMid:8456533.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 91-92
    • Hynynen, K.1    Damianou, C.2    Darkazanli, A.3
  • 7
    • 84856609858 scopus 로고    scopus 로고
    • Volumetric feedback ablation of uterine fibroids using magnetic resonance-guided high intensity focused ultrasound therapy
    • doi:10.1007/s00330-011-2262-8. PMid:21901565
    • Voogt MJ, Trillaud H, Kim YS, et al. Volumetric feedback ablation of uterine fibroids using magnetic resonance-guided high intensity focused ultrasound therapy. Eur Radiol 2012; 22: 411-417. doi:10.1007/s00330-011-2262-8. PMid:21901565.
    • (2012) Eur Radiol , vol.22 , pp. 411-417
    • Voogt, M.J.1    Trillaud, H.2    Kim, Y.S.3
  • 8
    • 84860319165 scopus 로고    scopus 로고
    • MR-guided high-intensity focused ultrasound for noninvasive cancer treatment
    • doi:10.1102/1470-7330.2011.9041. PMid:22180520
    • Huisman M, van den Bosch MA. MR-guided high-intensity focused ultrasound for noninvasive cancer treatment. Cancer Imaging 2011; 11: S161-166. doi:10.1102/1470-7330.2011.9041. PMid:22180520.
    • (2011) Cancer Imaging , vol.11
    • Huisman, M.1    Van Den Bosch, M.A.2
  • 9
    • 74749103085 scopus 로고    scopus 로고
    • Leiomyoma shrinkage after MRI-guided focused ultrasound treatment; report of 80 patients
    • doi:10.2214/AJR.09.2842
    • LeBlang SD, Hoctor K, Steinberg FL. Leiomyoma shrinkage after MRI-guided focused ultrasound treatment; report of 80 patients. Am J Roentgenol 2010; 194: 274-280. doi:10.2214/AJR.09.2842.
    • (2010) Am J Roentgenol , vol.194 , pp. 274-280
    • LeBlang, S.D.1    Hoctor, K.2    Steinberg, F.L.3
  • 10
    • 0038077326 scopus 로고    scopus 로고
    • Histologic evolution of high-intensity focused ultrasound in rabbit muscle
    • PMid:12750619
    • Solomon SB, Nicol TL, Chan DY, et al. Histologic evolution of high-intensity focused ultrasound in rabbit muscle. Invest Radiol 2003; 38: 293-301. PMid:12750619.
    • (2003) Invest Radiol , vol.38 , pp. 293-301
    • Solomon, S.B.1    Nicol, T.L.2    Chan, D.Y.3
  • 11
    • 45849096087 scopus 로고    scopus 로고
    • Image-guided focused ultrasound ablation of breast cancer; current status, challenges, and future directions
    • doi:10.1007/s00330-008-0906-0. PMid:18351348
    • Schmitz AC, Gianfelice D, Daniel BL, et al. Image-guided focused ultrasound ablation of breast cancer; current status, challenges, and future directions. Eur Radiol 2008; 18: 1431-1441. doi:10.1007/s00330-008-0906-0. PMid:18351348.
    • (2008) Eur Radiol , vol.18 , pp. 1431-1441
    • Schmitz, A.C.1    Gianfelice, D.2    Daniel, B.L.3
  • 12
    • 34047233897 scopus 로고    scopus 로고
    • Study of sequential histopathologic changes, apoptosis, and cell proliferation in rabbit livers after high-intensity focused ultrasound ablation
    • PMid:17384045
    • Luo W, Zhou X, Gong X, et al. Study of sequential histopathologic changes, apoptosis, and cell proliferation in rabbit livers after high-intensity focused ultrasound ablation. J Ultrasound Med 2007; 26: 477-485. PMid:17384045.
    • (2007) J Ultrasound Med , vol.26 , pp. 477-485
    • Luo, W.1    Zhou, X.2    Gong, X.3
  • 14
    • 0033905694 scopus 로고    scopus 로고
    • Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits
    • PMid:10924580
    • McDannold NJ, King RL, Jolesz FA. Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. Radiology 2000; 216: 517-523. PMid:10924580.
    • (2000) Radiology , vol.216 , pp. 517-523
    • McDannold, N.J.1    King, R.L.2    Jolesz, F.A.3
  • 15
    • 0028785052 scopus 로고
    • A precise and fast temperature mapping using water proton chemical shift
    • doi:10.1002/mrm.1910340606
    • Ishihara Y, Calderon A, Watanabe H, et al. A precise and fast temperature mapping using water proton chemical shift. Magn Resonance Med 1995; 34: 814-823. doi:10.1002/mrm.1910340606.
    • (1995) Magn Resonance Med , vol.34 , pp. 814-823
    • Ishihara, Y.1    Calderon, A.2    Watanabe, H.3
  • 16
    • 0021277965 scopus 로고
    • Thermal dose determination in cancer therapy
    • doi:10.1016/0360-3016(84)90379-1. PMid:6547421
    • Sapareto S, Dewey W. Thermal dose determination in cancer therapy. Int J Radiat Oncol Biol Phys 1984; 10: 787-800. doi:10.1016/0360-3016(84)90379-1. PMid:6547421.
    • (1984) Int J Radiat Oncol Biol Phys , vol.10 , pp. 787-800
    • Sapareto, S.1    Dewey, W.2
  • 17
    • 0028299454 scopus 로고
    • The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery
    • doi:10.1121/1.408550. PMid:8176064
    • Damianou C, Hynynen K. The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. J Acoust Soc Am 1994; 95: 1641-1649. doi:10.1121/1.408550. PMid:8176064.
    • (1994) J Acoust Soc Am , vol.95 , pp. 1641-1649
    • Damianou, C.1    Hynynen, K.2
  • 18
    • 0038714531 scopus 로고    scopus 로고
    • Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
    • doi:10.1080/0265673031000119006. PMid:12745972
    • Dewhirst MW, Viglianti BL, Lora-Michiels M, et al. Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia. Int J Hyperthermia 2003; 19: 267-294. doi:10.1080/0265673031000119006. PMid:12745972.
    • (2003) Int J Hyperthermia , vol.19 , pp. 267-294
    • Dewhirst, M.W.1    Viglianti, B.L.2    Lora-Michiels, M.3
  • 19
    • 79956204592 scopus 로고    scopus 로고
    • Thresholds for thermal damage to normal tissues; an update
    • doi:10.3109/02656736.2010.534527. PMid:21591897
    • Yarmolenko PS, Moon EJ, Landon C, et al. Thresholds for thermal damage to normal tissues; an update. Int J Hyperthermia 2011; 27: 320-343. doi:10.3109/02656736.2010.534527. PMid:21591897.
    • (2011) Int J Hyperthermia , vol.27 , pp. 320-343
    • Yarmolenko, P.S.1    Moon, E.J.2    Landon, C.3
  • 20
    • 68149162624 scopus 로고    scopus 로고
    • Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry
    • Köhler MO, Mougenot C, Quesson B, et al. Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry. Med Phys 2009; 36: 3521.
    • (2009) Med Phys , vol.36 , pp. 3521
    • Köhler, M.O.1    Mougenot, C.2    Quesson, B.3
  • 21
    • 0033808921 scopus 로고    scopus 로고
    • Local hyperthermia with MR-guided focused ultrasound; spiral trajectory of the focal point optimized for temperature uniformity in the target region
    • doi:10.1002/1522-2586(200010)12:4〈571::AID-JMRI9〉3.0.CO;2-2. PMid:11042639
    • Salomir R, Palussie're J, Vimeux FC, et al. Local hyperthermia with MR-guided focused ultrasound; spiral trajectory of the focal point optimized for temperature uniformity in the target region. J Magn Reson Imaging 2000; 12: 571-583. doi:10.1002/1522-2586(200010)12:4〈571::AID-JMRI9〉3.0.CO;2-2. PMid:11042639.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 571-583
    • Salomir, R.1    Palussie'Re, J.2    Vimeux, F.C.3
  • 22
    • 0037225633 scopus 로고    scopus 로고
    • Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh
    • DOI 10.1002/mrm.10328
    • Palussière J, Salomir R, Le Bail B, et al. Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh. Magn Reson Med 2003; 49: 89-98. (Pubitemid 36042337)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.1 , pp. 89-98
    • Palussiere, J.1    Salomir, R.2    Le, B.B.3    Fawaz, R.4    Quesson, B.5    Grenier, N.6    Moonen, C.T.W.7
  • 23
    • 62649128390 scopus 로고    scopus 로고
    • Three-dimensional spatial and temporal temperature control with MR thermometry-guided focused ultrasound (MRgHIFU)
    • doi:10.1002/mrm.21887. PMid:19097249
    • Mougenot C, Quesson B, de Senneville BD, et al. Three-dimensional spatial and temporal temperature control with MR thermometry-guided focused ultrasound (MRgHIFU). Magn Reson Med 2009; 61: 603-614. doi:10.1002/mrm.21887. PMid:19097249.
    • (2009) Magn Reson Med , vol.61 , pp. 603-614
    • Mougenot, C.1    Quesson, B.2    De Senneville, B.D.3
  • 24
    • 0024407776 scopus 로고
    • High intensity focused ultrasound - A surgical technique for the treatment of discrete liver tumours
    • Ter Haar G, Sinnett D, Rivens I. High intensity focused ultrasound - a surgical technique for the treatment of discrete liver tumours. Physics Med Biol 1989; 34: 1743-1750. doi:10.1088/0031-9155/34/11/021. (Pubitemid 19265780)
    • (1989) Physics in Medicine and Biology , vol.34 , Issue.11 , pp. 1743-1750
    • Ter, H.G.1    Sinnett, D.2    Rivens, I.3
  • 25
    • 0015746462 scopus 로고
    • Localized tissue destruction by high-intensity focused ultrasound
    • doi:10.1001/archsurg.1973.01350240053015. PMid:4751833
    • Linke C, Carstensen E, Frizzell L, et al. Localized tissue destruction by high-intensity focused ultrasound. Arch Surg 1973; 107: 887-891. doi:10.1001/archsurg.1973.01350240053015. PMid:4751833.
    • (1973) Arch Surg , vol.107 , pp. 887-891
    • Linke, C.1    Carstensen, E.2    Frizzell, L.3
  • 26
    • 0026407998 scopus 로고
    • High-intensity focused ultrasound in the treatment of experimental liver cancer
    • doi:10.1001/archsurg.1991.01410320088012. PMid:1863205
    • Yang R, Reilly C, Rescorla F. High-intensity focused ultrasound in the treatment of experimental liver cancer. Arch Surg 1991; 126: 1002-1009. doi:10.1001/archsurg.1991.01410320088012. PMid:1863205.
    • (1991) Arch Surg , vol.126 , pp. 1002-1009
    • Yang, R.1    Reilly, C.2    Rescorla, F.3
  • 27
    • 0031054756 scopus 로고    scopus 로고
    • MRI study of hepatic tumours following high intensity focused ultrasound surgery
    • PMid:9135440
    • Rowland IJ, Rivens I, Chen L, et al. MRI study of hepatic tumours following high intensity focused ultrasound surgery. Br J Radiol 1997; 70: 144-153. PMid:9135440.
    • (1997) Br J Radiol , vol.70 , pp. 144-153
    • Rowland, I.J.1    Rivens, I.2    Chen, L.3
  • 28
    • 0027751885 scopus 로고
    • Characterization of extracorporeal ablation of normal and tumor-bearing liver tissue by high intensity focused ultrasound
    • doi:10.1016/0301-5629(93)90096-7. PMid:8134980
    • Sibille A, Prat F, Chapelon JY, et al. Characterization of extracorporeal ablation of normal and tumor-bearing liver tissue by high intensity focused ultrasound. Ultrasound Med Biol 1993; 19: 803-813. doi:10.1016/0301-5629(93) 90096-7. PMid:8134980.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 803-813
    • Sibille, A.1    Prat, F.2    Chapelon, J.Y.3
  • 29
    • 0028959115 scopus 로고
    • Extracorporeal high-intensity focused ultrasound for VX2 liver tumors in the rabbit
    • PMid:7875681
    • Prat F, Centarti M, Sibille A, et al. Extracorporeal high-intensity focused ultrasound for VX2 liver tumors in the rabbit. Hepatology 1995; 21: 832-836. PMid:7875681.
    • (1995) Hepatology , vol.21 , pp. 832-836
    • Prat, F.1    Centarti, M.2    Sibille, A.3
  • 30
    • 0028909267 scopus 로고
    • Focused US system for MR imaging-guided tumor ablation
    • PMid:7862971
    • Cline E, Schenck JF, Ettinger RH, et al. Focused US system for MR imaging-guided tumor ablation. Radiology 1995; 194: 731-737. PMid:7862971.
    • (1995) Radiology , vol.194 , pp. 731-737
    • Cline, E.1    Schenck, J.F.2    Ettinger, R.H.3
  • 32
    • 33746328973 scopus 로고    scopus 로고
    • Magnetic resonance-guided focused ultrasound surgery (MRgFUS); ablation of liver tissue in a porcine model
    • doi:10.1016/j.ejrad.2006.04.008. PMid:16725294
    • Kopelman D, Inbar Y, Hanannel A, et al. Magnetic resonance-guided focused ultrasound surgery (MRgFUS); ablation of liver tissue in a porcine model. Eur J Radiol 2006; 59: 157-162. doi:10.1016/j.ejrad.2006.04.008. PMid:16725294.
    • (2006) Eur J Radiol , vol.59 , pp. 157-162
    • Kopelman, D.1    Inbar, Y.2    Hanannel, A.3
  • 33
    • 0032933070 scopus 로고    scopus 로고
    • Preliminary results of a phase i dose escalation clinical trial using focused ultrasound in the treatment of localised tumours
    • doi:10.1016/S0929-8266(99)00009-9. PMid:10099162
    • Visioli aG, Rivens IH, ter Haar GR, et al. Preliminary results of a phase I dose escalation clinical trial using focused ultrasound in the treatment of localised tumours. Eur J Ultrasound 1999; 9: 11-18. doi:10.1016/S0929-8266(99) 00009-9. PMid:10099162.
    • (1999) Eur J Ultrasound , vol.9 , pp. 11-18
    • Visioli, A.G.1    Rivens, I.H.2    Ter Haar, G.R.3
  • 34
    • 27144503075 scopus 로고    scopus 로고
    • The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population
    • doi:10.1038/sj.bjc.6602803. PMid:16189519
    • Illing RO, Kennedy JE, Wu F, et al. The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population. Br J Cancer 2005; 93: 890-895. doi:10.1038/sj.bjc.6602803. PMid:16189519.
    • (2005) Br J Cancer , vol.93 , pp. 890-895
    • Illing, R.O.1    Kennedy, J.E.2    Wu, F.3
  • 35
    • 1642601566 scopus 로고    scopus 로고
    • High-intensity focused ultrasound for the treatment of liver tumours
    • doi:10.1016/j.ultras.2004.01.089. PMid:15047409
    • Kennedy JE, Wu F, ter Haar GR, et al. High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics 2004; 42: 931-935. doi:10.1016/j.ultras.2004.01.089. PMid:15047409.
    • (2004) Ultrasonics , vol.42 , pp. 931-935
    • Kennedy, J.E.1    Wu, F.2    Ter Haar, G.R.3
  • 36
    • 10744226073 scopus 로고    scopus 로고
    • Extracorporeal focused ultrasound surgery for treatment of human solid carcinomas; early Chinese clinical experience
    • doi:10.1016/j.ultrasmedbio.2003.10.010. PMid:14998677
    • Wu F, Wang ZB, Chen WZ, et al. Extracorporeal focused ultrasound surgery for treatment of human solid carcinomas; early Chinese clinical experience. Ultrasound Med Biol 2004; 30: 245-260. doi:10.1016/j.ultrasmedbio.2003.10.010. PMid:14998677.
    • (2004) Ultrasound Med Biol , vol.30 , pp. 245-260
    • Wu, F.1    Wang, Z.B.2    Chen, W.Z.3
  • 37
    • 11144354898 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: An overview
    • DOI 10.1016/j.ultsonch.2004.01.011, PII S1350417704000136
    • Wu F, Wang ZB, Chen WZ, et al. Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China; an overview. Ultrasonics Sonochem 2004; 11: 149-154. doi:10.1016/j. ultsonch.2004.01.011. (Pubitemid 38479821)
    • (2004) Ultrasonics Sonochemistry , vol.11 , Issue.3-4 , pp. 149-154
    • Wu, F.1    Wang, Z.-B.2    Chen, W.-Z.3    Wang, W.4    Gui, Y.5    Zhang, M.6    Zheng, G.7    Zhou, Y.8    Xu, G.9    Li, M.10    Zhang, C.11    Ye, H.12    Feng, R.13
  • 38
    • 38949202975 scopus 로고    scopus 로고
    • A case of hepatocellular carcinoma treated by MR-guided focused ultrasound ablation with respiratory gating
    • doi:10.2463/mrms.5.167. PMid:17139143
    • Okada A, Murakami T, Mikami K, et al. A case of hepatocellular carcinoma treated by MR-guided focused ultrasound ablation with respiratory gating. Magn Reson Med Sci 2006; 5: 167-171. doi:10.2463/mrms.5.167. PMid:17139143.
    • (2006) Magn Reson Med Sci , vol.5 , pp. 167-171
    • Okada, A.1    Murakami, T.2    Mikami, K.3
  • 39
    • 78649593742 scopus 로고    scopus 로고
    • Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues
    • doi:10.1002/mrm.22548. PMid:20878763
    • Ries M, de Senneville BD, Roujol S, et al. Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues. Magn Reson Med 2010; 64: 1704-1712. doi:10.1002/mrm.22548. PMid:20878763.
    • (2010) Magn Reson Med , vol.64 , pp. 1704-1712
    • Ries, M.1    De Senneville, B.D.2    Roujol, S.3
  • 40
    • 80051587968 scopus 로고    scopus 로고
    • In vivo characterization of tissue thermal properties of the kidney during local hyperthermia induced by MR-guided high-intensity focused ultrasound
    • doi:10.1002/nbm.1624. PMid:21834004
    • Cornelis F, Grenier N, Moonen CT, et al. In vivo characterization of tissue thermal properties of the kidney during local hyperthermia induced by MR-guided high-intensity focused ultrasound. NMR Biomed 2011; 24: 799-806. doi:10.1002/nbm.1624. PMid:21834004.
    • (2011) NMR Biomed , vol.24 , pp. 799-806
    • Cornelis, F.1    Grenier, N.2    Moonen, C.T.3
  • 41
    • 33846815451 scopus 로고    scopus 로고
    • Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound
    • doi:10.1002/mrm.21124. PMid:17260361
    • De Senneville BD, Mougenot C, Moonen CT. Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound. Magn Reson Med 2007; 57: 319-330. doi:10.1002/mrm.21124. PMid:17260361.
    • (2007) Magn Reson Med , vol.57 , pp. 319-330
    • De Senneville, B.D.1    Mougenot, C.2    Moonen, C.T.3
  • 42
    • 0041411671 scopus 로고    scopus 로고
    • High power transcranial beam steering for ultrasonic brain therapy
    • DOI 10.1088/0031-9155/48/16/301, PII S0031915503594623
    • Pernot M, Aubry J, Tanter M. High power transcranial beam steering for ultrasonic brain therapy. Physics Med Biol 2003; 48: 2577-2589. doi:10.1088/0031-9155/48/16/301. (Pubitemid 37069368)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.16 , pp. 2577-2589
    • Pernot, M.1    Aubry, J.-F.2    Tanter, M.3    Thomas, J.-L.4    Fink, M.5
  • 43
    • 80155134692 scopus 로고    scopus 로고
    • Optimal transcostal high-intensity focused ultrasound with combined real-time 3D movement tracking and correction
    • doi:10.1088/0031-9155/56/22/005
    • Marquet F, Aubry JF, Pernot M, et al. Optimal transcostal high-intensity focused ultrasound with combined real-time 3D movement tracking and correction. Physics Med Biol 2011; 56: 7061-7080. doi:10.1088/0031-9155/56/22/005.
    • (2011) Physics Med Biol , vol.56 , pp. 7061-7080
    • Marquet, F.1    Aubry, J.F.2    Pernot, M.3
  • 44
    • 77953495687 scopus 로고    scopus 로고
    • A method for MRI guidance of intercostal high intensity focused ultrasound ablation in the liver
    • doi:10.1118/1.3413996. PMid:20632565
    • Quesson B, Merle M, Köhler MO, et al. A method for MRI guidance of intercostal high intensity focused ultrasound ablation in the liver. Med Phys 2010; 37: 2533. doi:10.1118/1.3413996. PMid:20632565.
    • (2010) Med Phys , vol.37 , pp. 2533
    • Quesson, B.1    Merle, M.2    Köhler, M.O.3
  • 45
    • 0031344419 scopus 로고    scopus 로고
    • Optimal synthesis of phased array field patterns in the presence of the ribcage
    • Botros Y, Ebbini E, Volakis J. Optimal synthesis of phased array field patterns in the presence of the ribcage. IEEE Ultrasonics Symp 1997; 2: 1751-1754.
    • (1997) IEEE Ultrasonics Symp , vol.2 , pp. 1751-1754
    • Botros, Y.1    Ebbini, E.2    Volakis, J.3
  • 47
    • 1942501551 scopus 로고    scopus 로고
    • Percutaneous Radiofrequency Ablation Guided by Contrast-Enhanced Harmonic Sonography with Artificial Pleural Effusion for Hepatocellular Carcinoma in the Hepatic Dome
    • Minami Y, Kudo M, Kawasaki T, et al. Percutaneous radiofrequency ablation guided by contrast-enhanced harmonic sonography with artificial pleural effusion for hepatocellular carcinoma in the hepatic dome. Am J Radiol 2004; 182: 1224-1226. (Pubitemid 38525518)
    • (2004) American Journal of Roentgenology , vol.182 , Issue.5 , pp. 1224-1226
    • Minami, Y.1    Kudo, M.2    Kawasaki, T.3    Chung, H.4    Ogawa, C.5    Shiozaki, H.6
  • 48
    • 0027527941 scopus 로고
    • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound
    • doi:10.1088/0031-9155/38/11/011. PMid:8272440
    • Chen L, Ter Haar G, Hill CR, et al. Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound. Phys Med Biol 1993; 38: 1661-1673. doi:10.1088/0031-9155/38/11/011. PMid:8272440.
    • (1993) Phys Med Biol , vol.38 , pp. 1661-1673
    • Chen, L.1    Ter Haar, G.2    Hill, C.R.3
  • 49
    • 51649099444 scopus 로고    scopus 로고
    • Local recurrence after laparoscopic radiofrequency ablation of liver tumors; an analysis of 1032 tumors
    • doi:10.1245/s10434-008-0043-7. PMid:18618182
    • Berber E, Siperstein A. Local recurrence after laparoscopic radiofrequency ablation of liver tumors; an analysis of 1032 tumors. Ann Surg Oncol 2008; 15: 2757-2764. doi:10.1245/s10434-008-0043-7. PMid:18618182.
    • (2008) Ann Surg Oncol , vol.15 , pp. 2757-2764
    • Berber, E.1    Siperstein, A.2
  • 50
    • 33846899004 scopus 로고    scopus 로고
    • Effects of large blood vessel locations during high intensity focused ultrasound therapy for hepatic tumors: A finite element study
    • 1616380, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    • Zhang CX, Zhang Z, Chen YZ. Effects of large blood vessel locations during high intensity focused ultrasound therapy for hepatic tumors; a finite element study (conference proceedings). IEEE Engin Med Biol Soc 2005; 1: 209-212. (Pubitemid 46228831)
    • (2005) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , vol.7 VOLS , pp. 209-212
    • Zhang, C.X.1    Zhang, S.2    Zhang, Z.3    Chen, Y.Z.4
  • 51
    • 59249093178 scopus 로고    scopus 로고
    • High-intensity focused ultrasound (HIFU); effective and safe therapy for hepatocellular carcinoma adjacent to major hepatic veins
    • doi:10.1007/s00330-008-1137-0. PMid:18795303
    • Zhang L, Zhu H, Jin C, et al. High-intensity focused ultrasound (HIFU); effective and safe therapy for hepatocellular carcinoma adjacent to major hepatic veins. Eur Radiol 2009; 19: 437-445. doi:10.1007/s00330-008-1137-0. PMid:18795303.
    • (2009) Eur Radiol , vol.19 , pp. 437-445
    • Zhang, L.1    Zhu, H.2    Jin, C.3
  • 52
    • 77956792595 scopus 로고    scopus 로고
    • High-intensity focused ultrasound ablation; effective and safe therapy for solid tumors in difficult locations
    • doi:10.2214/AJR.09.3321
    • Orsi F, Zhang L, Arnone P, et al. High-intensity focused ultrasound ablation; effective and safe therapy for solid tumors in difficult locations. Am J Roentgenol 2010; 195: W245-252. doi:10.2214/AJR.09.3321.
    • (2010) Am J Roentgenol , vol.195
    • Orsi, F.1    Zhang, L.2    Arnone, P.3
  • 53
    • 79951833705 scopus 로고    scopus 로고
    • Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo; a feasibility study in pig liver and kidney
    • doi:10.1002/nbm.1563. PMid:21344531
    • Quesson B, Laurent C, Maclair G, et al. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo; a feasibility study in pig liver and kidney. NMR Biomed 2011; 24: 145-153. doi:10.1002/nbm.1563. PMid:21344531.
    • (2011) NMR Biomed , vol.24 , pp. 145-153
    • Quesson, B.1    Laurent, C.2    Maclair, G.3
  • 54
    • 36348950174 scopus 로고    scopus 로고
    • Short and long term efficacy of high intensity focused ultrasound therapy for advanced hepatocellular carcinoma
    • doi:10.1111/j.1440-1746.2006.04719.x. PMid:18031373
    • Li YY, Sha WH, Zhou YJ, et al. Short and long term efficacy of high intensity focused ultrasound therapy for advanced hepatocellular carcinoma. J Gastroenterol Hepatol 2007; 22: 2148-2154. doi:10.1111/j.1440-1746.2006.04719.x. PMid:18031373.
    • (2007) J Gastroenterol Hepatol , vol.22 , pp. 2148-2154
    • Li, Y.Y.1    Sha, W.H.2    Zhou, Y.J.3
  • 55
    • 79955463020 scopus 로고    scopus 로고
    • High-intensity focused ultrasound ablation in hepatic and pancreatic cancer; complications
    • doi:10.1007/s00261-010-9628-2. PMid:20512487
    • Jung SE, Cho SH, Jang JH, et al. High-intensity focused ultrasound ablation in hepatic and pancreatic cancer; complications. Abdom Imaging 2011; 36: 185-195. doi:10.1007/s00261-010-9628-2. PMid:20512487.
    • (2011) Abdom Imaging , vol.36 , pp. 185-195
    • Jung, S.E.1    Cho, S.H.2    Jang, J.H.3
  • 56
    • 82955248106 scopus 로고    scopus 로고
    • Follow-up of high-intensity focused ultrasound treatment for patients with hepatocellular carcinoma
    • doi:10.1016/j.ultrasmedbio.2011.08.011. PMid:22036638
    • Xu G, Luo G, He L, et al. Follow-up of high-intensity focused ultrasound treatment for patients with hepatocellular carcinoma. Ultrasound Med Biol 2011; 37: 1993-1999. doi:10.1016/j.ultrasmedbio.2011.08.011. PMid:22036638.
    • (2011) Ultrasound Med Biol , vol.37 , pp. 1993-1999
    • Xu, G.1    Luo, G.2    He, L.3
  • 57
    • 80052271746 scopus 로고    scopus 로고
    • Evaluation of short-term response of high intensity focused ultrasound ablation for primary hepatic carcinoma; utility of contrast-enhanced MRI and diffusion-weighted imaging
    • doi:10.1016/j.ejrad.2010.06.039. PMid:20638211
    • Zhang Y, Zhao J, Guo D, et al. Evaluation of short-term response of high intensity focused ultrasound ablation for primary hepatic carcinoma; utility of contrast-enhanced MRI and diffusion-weighted imaging. Eur J Radiol 2011; 79: 347-352. doi:10.1016/j.ejrad.2010.06.039. PMid:20638211.
    • (2011) Eur J Radiol , vol.79 , pp. 347-352
    • Zhang, Y.1    Zhao, J.2    Guo, D.3
  • 58
    • 80755172582 scopus 로고    scopus 로고
    • High-intensity focused ultrasound combined with transarterial chemoembolization for unresectable hepatocellular carcinoma; long-term follow-up and clinical analysis
    • doi:10.1016/j.ejrad.2010.08.042. PMid:20864286
    • Jin C, Zhu H, Wang Z, et al. High-intensity focused ultrasound combined with transarterial chemoembolization for unresectable hepatocellular carcinoma; long-term follow-up and clinical analysis. Eur J Radiol 2011; 80: 662-669. doi:10.1016/j.ejrad.2010.08.042. PMid:20864286.
    • (2011) Eur J Radiol , vol.80 , pp. 662-669
    • Jin, C.1    Zhu, H.2    Wang, Z.3
  • 59
    • 79959841765 scopus 로고    scopus 로고
    • Treatment of small hepatocellular carcinomas with US-guided high-intensity focused ultrasound
    • doi:10.1016/j.ultrasmedbio.2011.04.020. PMid:21645963
    • Fukuda H, Ito R, Ohto M, et al. Treatment of small hepatocellular carcinomas with US-guided high-intensity focused ultrasound. Ultrasound Med Biol 2011; 37: 1222-1229. doi:10.1016/j.ultrasmedbio.2011.04.020. PMid:21645963.
    • (2011) Ultrasound Med Biol , vol.37 , pp. 1222-1229
    • Fukuda, H.1    Ito, R.2    Ohto, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.