메뉴 건너뛰기




Volumn 54, Issue 10, 2012, Pages 1121-1125

Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms

Author keywords

Artifacts; CT; Flat panel detector; Intracranial aneurysm; Stent

Indexed keywords

ACCURACY; ARTICLE; ARTIFACT; CLINICAL ARTICLE; COIL EMBOLIZATION; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; IMAGE QUALITY; INTERRATER RELIABILITY; INTRACRANIAL ANEURYSM; INTRACRANIAL STENT; NEUROIMAGING; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STENT; STENT KINKING; STENT MIDEPLOYMENT; THREE DIMENSIONAL IMAGING;

EID: 84867892837     PISSN: 00283940     EISSN: 14321920     Source Type: Journal    
DOI: 10.1007/s00234-011-1002-8     Document Type: Article
Times cited : (22)

References (17)
  • 1
    • 85047686206 scopus 로고    scopus 로고
    • Advances in interventional neuroradiology
    • 19398765 10.1161/STROKEAHA.109.548438
    • Wakhloo AK, Deleo MJ 3rd, Brown MM (2009) Advances in interventional neuroradiology. Stroke 40:e305-e312
    • (2009) Stroke , vol.40
    • Wakhloo, A.K.1    Deleo III, M.J.2    Brown, M.M.3
  • 2
    • 33748298872 scopus 로고    scopus 로고
    • Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms
    • 16823325 10.1227/01.NEU.0000223650.11954.6C discussion 291-300
    • Fiorella D, Albuquerque FC, Deshmukh VR et al (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59:291-300, discussion 291-300
    • (2006) Neurosurgery , vol.59 , pp. 291-300
    • Fiorella, D.1    Albuquerque, F.C.2    Deshmukh, V.R.3
  • 4
    • 20044393656 scopus 로고    scopus 로고
    • Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: Results at initial (3-6-mo) follow-up
    • DOI 10.1227/01.NEU.0000159645.86823.AF
    • Fiorella D, Albuquerque FC, Deshmukh VR et al (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up. Neurosurgery 56:1191-1201, discussion 1201-1192 (Pubitemid 40770430)
    • (2005) Neurosurgery , vol.56 , Issue.6 , pp. 1191-1201
    • Fiorella, D.1    Albuquerque, F.C.2    Deshmukh, V.R.3    McDougall, C.G.4
  • 5
    • 34548817587 scopus 로고    scopus 로고
    • Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up
    • 17881956 10.1227/01.NEU.0000290890.62201.A9 discussion 468-469
    • Biondi A, Janardhan V, Katz JM et al (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460-468, discussion 468-469
    • (2007) Neurosurgery , vol.61 , pp. 460-468
    • Biondi, A.1    Janardhan, V.2    Katz, J.M.3
  • 6
    • 77955600356 scopus 로고    scopus 로고
    • Neuroform stent-assisted coiling of intracranial aneurysms: A 5 year single-center experience and follow-up
    • 19660196 10.1179/016164109X12445616596409
    • Liang G, Gao X, Li Z et al (2009) Neuroform stent-assisted coiling of intracranial aneurysms: a 5 year single-center experience and follow-up. Neurol Res 32(7):721-727
    • (2009) Neurol Res , vol.32 , Issue.7 , pp. 721-727
    • Liang, G.1    Gao, X.2    Li, Z.3
  • 7
    • 74049160364 scopus 로고    scopus 로고
    • Stent-assisted coiling of intracranial aneurysms. Clinical and angiographic results in 216 consecutive aneurysms
    • 19959540 10.1161/STROKEAHA.109.558114
    • Piotin M, Blanc R, Spelle L et al (2010) Stent-assisted coiling of intracranial aneurysms. Clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110-115
    • (2010) Stroke , vol.41 , pp. 110-115
    • Piotin, M.1    Blanc, R.2    Spelle, L.3
  • 8
    • 33646192862 scopus 로고    scopus 로고
    • Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: Value of angiographic computed tomography: Technical case report
    • 16575290 discussion ONS-E380
    • Benndorf G, Claus B, Strother CM et al (2006) Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report. Neurosurgery 58:ONS-E380, discussion ONS-E380
    • (2006) Neurosurgery , vol.58 , pp. 380
    • Benndorf, G.1    Claus, B.2    Strother, C.M.3
  • 10
    • 34248639072 scopus 로고    scopus 로고
    • Stent conformity in curved vascular models with simulated aneurysm weeks using Flat-Panel CT: An in vitro study
    • Ebrahimi N, Claus B, Lee CY et al (2007) Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study. AJNR Am J Neuroradiol 28:823-829 (Pubitemid 46776055)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.5 , pp. 823-829
    • Ebrahimi, N.1    Claus, B.2    Lee, C.-Y.3    Biondi, A.4    Benndorf, G.5
  • 12
    • 53849088567 scopus 로고    scopus 로고
    • Rotational flat-panel computed tomography in diagnostic and interventional neuroradiology
    • 19238639 10.1055/s-2008-1073187 1:STN:280:DC%2BD1M7mt1Smug%3D%3D
    • Dorfler A, Struffert T, Engelhorn T et al (2008) Rotational flat-panel computed tomography in diagnostic and interventional neuroradiology. Rofo 180:891-898
    • (2008) Rofo , vol.180 , pp. 891-898
    • Dorfler, A.1    Struffert, T.2    Engelhorn, T.3
  • 13
    • 41149103858 scopus 로고    scopus 로고
    • Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting
    • 18246336 10.1007/s00234-007-0342-x
    • Buhk JH, Lingor P, Knauth M (2008) Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting. Neuroradiology 50:349-354
    • (2008) Neuroradiology , vol.50 , pp. 349-354
    • Buhk, J.H.1    Lingor, P.2    Knauth, M.3
  • 15
    • 52949115653 scopus 로고    scopus 로고
    • Brain imaging with a flat detector C-arm: Technique and clinical interest of XperCT
    • 18560818 10.1007/s00234-008-0419-1 1:STN:280:DC%2BD1cnis1GrsQ%3D%3D
    • Soderman M, Babic D, Holmin S et al (2008) Brain imaging with a flat detector C-arm: technique and clinical interest of XperCT. Neuroradiology 50:863-868
    • (2008) Neuroradiology , vol.50 , pp. 863-868
    • Soderman, M.1    Babic, D.2    Holmin, S.3
  • 16
    • 67650742249 scopus 로고    scopus 로고
    • Spontaneous delayed proximal migration of enterprise stent after staged treatment of wide-necked basilar aneurysm: Technical case report
    • 19404126 10.1227/01.NEU.0000343745.18753.D6 discussion E1012
    • Lavine SD, Meyers PM, Connolly ES et al (2009) Spontaneous delayed proximal migration of enterprise stent after staged treatment of wide-necked basilar aneurysm: technical case report. Neurosurgery 64:E1012, discussion E1012
    • (2009) Neurosurgery , vol.64 , pp. 1012
    • Lavine, S.D.1    Meyers, P.M.2    Connolly, E.S.3
  • 17
    • 64649093679 scopus 로고    scopus 로고
    • Wall shear stress in intracranial self-expanding stents studied using ultra-high-resolution 3D reconstructions
    • 19039050 10.3174/ajnr.A1396 1:STN:280:DC%2BD1M3gtFSmsQ%3D%3D
    • Benndorf G, Ionescu M, MV YA et al (2009) Wall shear stress in intracranial self-expanding stents studied using ultra-high-resolution 3D reconstructions. AJNR Am J Neuroradiol 30:479-486
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 479-486
    • Benndorf, G.1    Ionescu, M.2    Mv, Y.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.