메뉴 건너뛰기




Volumn 24, Issue 7, 2012, Pages 561-565

Comparison of the Pentax-AWS Airway Scope with the Macintosh laryngoscope for nasotracheal intubation: A randomized, prospective study

Author keywords

Difficult airway management; Nasotracheal intubation; Pentax AWS Airway Scope

Indexed keywords

ADULT; AGED; ARTICLE; AWS AIRWAY SCOPE; CLINICAL EFFECTIVENESS; COMPARATIVE STUDY; CONTROLLED STUDY; DEVICES; ENDOTRACHEAL TUBE; EPIGLOTTIS; FEMALE; GLOTTIS; HOARSENESS; HUMAN; LARYNGOSCOPE; LARYNX; MAJOR CLINICAL STUDY; MALE; NASOTRACHEAL INTUBATION; OPERATING ROOM; ORTHODONTICS; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; RATING SCALE; SORE THROAT; UNIVERSITY HOSPITAL;

EID: 84867796363     PISSN: 09528180     EISSN: 18734529     Source Type: Journal    
DOI: 10.1016/j.jclinane.2012.04.007     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 85047696151 scopus 로고    scopus 로고
    • Description and first clinical application of Airway Scope for tracheal intubation
    • J. Koyama, T. Aoyama, and Y. Kusano Description and first clinical application of Airway Scope for tracheal intubation J Neurosurg Anesthesiol 18 2006 247 250
    • (2006) J Neurosurg Anesthesiol , vol.18 , pp. 247-250
    • Koyama, J.1    Aoyama, T.2    Kusano, Y.3
  • 2
    • 36549036787 scopus 로고    scopus 로고
    • Nasotracheal intubation with the aid of the Airway Scope
    • Y. Hirabayashi Nasotracheal intubation with the aid of the Airway Scope J Clin Anesth 19 2007 563
    • (2007) J Clin Anesth , vol.19 , pp. 563
    • Hirabayashi, Y.1
  • 3
    • 41949087119 scopus 로고    scopus 로고
    • Nasal tracheal intubation improves the success rate when the Airway Scope blade fails to reach the larynx
    • H.Y. Lai, A. Chen, and Y. Lee Nasal tracheal intubation improves the success rate when the Airway Scope blade fails to reach the larynx Br J Anaesth 100 2008 566 567
    • (2008) Br J Anaesth , vol.100 , pp. 566-567
    • Lai, H.Y.1    Chen, A.2    Lee, Y.3
  • 5
    • 44449093559 scopus 로고    scopus 로고
    • Pentax-AWS (Airway Scope) and Airtraq: Big difference between two similar devices
    • A. Suzuki, N. Abe, T. Sasakawa, T. Kunisawa, O. Takahata, and H. Iwasaki Pentax-AWS (Airway Scope) and Airtraq: big difference between two similar devices J Anesth 22 2008 191 192
    • (2008) J Anesth , vol.22 , pp. 191-192
    • Suzuki, A.1    Abe, N.2    Sasakawa, T.3    Kunisawa, T.4    Takahata, O.5    Iwasaki, H.6
  • 6
    • 78651511788 scopus 로고    scopus 로고
    • Parker Flex-Tip Tube(®) facilitates intubation when the Pentax-AWS(®) fails to reach the larynx
    • T. Ohmura, A. Suzuki, A. Kurosawa, K. Fujimoto, T. Kunisawa, and H. Iwasaki Parker Flex-Tip Tube(®) facilitates intubation when the Pentax-AWS(®) fails to reach the larynx J Anesth 24 2010 974 975
    • (2010) J Anesth , vol.24 , pp. 974-975
    • Ohmura, T.1    Suzuki, A.2    Kurosawa, A.3    Fujimoto, K.4    Kunisawa, T.5    Iwasaki, H.6
  • 7
    • 79952248041 scopus 로고    scopus 로고
    • In reply: Comments on use of a Parker Flex-Tip tube(®) to facilitate intubation with the Pentax-AWS(®)
    • A. Suzuki, T. Ohmura, and T. Kunisawa In reply: Comments on use of a Parker Flex-Tip tube(®) to facilitate intubation with the Pentax-AWS(®) J Anesth 25 2011 133 134
    • (2011) J Anesth , vol.25 , pp. 133-134
    • Suzuki, A.1    Ohmura, T.2    Kunisawa, T.3
  • 8
    • 0032739013 scopus 로고    scopus 로고
    • Assessment of laryngeal view: Percentage of glottic opening score vs Cormack and Lehane grading
    • E.A. Ochroch, J.E. Hollander, S. Kush, F.S. Shofer, and R.M. Levitan Assessment of laryngeal view: percentage of glottic opening score vs Cormack and Lehane grading Can J Anaesth 46 1999 987 990
    • (1999) Can J Anaesth , vol.46 , pp. 987-990
    • Ochroch, E.A.1    Hollander, J.E.2    Kush, S.3    Shofer, F.S.4    Levitan, R.M.5
  • 9
    • 0031469105 scopus 로고    scopus 로고
    • The intubation difficulty scale (IDS): Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation
    • F. Adnet, S.W. Borron, and S.X. Racine The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation Anesthesiology 87 1997 1290 1297
    • (1997) Anesthesiology , vol.87 , pp. 1290-1297
    • Adnet, F.1    Borron, S.W.2    Racine, S.X.3
  • 10
    • 0031454226 scopus 로고    scopus 로고
    • Intubation difficulty scale: Anticipated best use
    • J.L. Benumof Intubation difficulty scale: anticipated best use Anesthesiology 87 1997 1273 1274
    • (1997) Anesthesiology , vol.87 , pp. 1273-1274
    • Benumof, J.L.1
  • 11
    • 43549107680 scopus 로고    scopus 로고
    • The Pentax-AWS((R)) rigid indirect video laryngoscope: Clinical assessment of performance in 320 cases
    • A. Suzuki, Y. Toyama, and N. Katsumi The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases Anaesthesia 63 2008 641 647
    • (2008) Anaesthesia , vol.63 , pp. 641-647
    • Suzuki, A.1    Toyama, Y.2    Katsumi, N.3
  • 12
    • 49849083659 scopus 로고    scopus 로고
    • A comparison of GlideScope videolaryngoscopy to direct laryngoscopy for nasotracheal intubation
    • P.M. Jones, K.P. Armstrong, and P.M. Armstrong A comparison of GlideScope videolaryngoscopy to direct laryngoscopy for nasotracheal intubation Anesth Analg 107 2008 144 148
    • (2008) Anesth Analg , vol.107 , pp. 144-148
    • Jones, P.M.1    Armstrong, K.P.2    Armstrong, P.M.3
  • 13
    • 78049271003 scopus 로고    scopus 로고
    • Nasotracheal intubation using GlideScope videolaryngoscope or Macintosh laryngoscope by novice laryngoscopists
    • M. Shimada, Y. Hirabayashi, and N. Seo Nasotracheal intubation using GlideScope videolaryngoscope or Macintosh laryngoscope by novice laryngoscopists Masui 59 2010 1318 1320
    • (2010) Masui , vol.59 , pp. 1318-1320
    • Shimada, M.1    Hirabayashi, Y.2    Seo, N.3
  • 14
    • 61349142483 scopus 로고    scopus 로고
    • Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists
    • Y. Hirabayashi, and N. Seo Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists J Anesth 23 2009 172 173
    • (2009) J Anesth , vol.23 , pp. 172-173
    • Hirabayashi, Y.1    Seo, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.