메뉴 건너뛰기




Volumn 64, Issue 1, 2013, Pages 640-649

Quantitative magnetization transfer imaging of human brain at 7T

Author keywords

7T; Brain; Magnetization transfer; Multiple sclerosis; Myelin; White matter

Indexed keywords

ADULT; ARTICLE; BRAIN RADIOGRAPHY; FEASIBILITY STUDY; FEMALE; GRAY MATTER; HUMAN; HUMAN EXPERIMENT; IMAGE PROCESSING; IMAGE QUALITY; IN VIVO STUDY; MAGNETIC FIELD; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIOFREQUENCY; RADIOLOGICAL PARAMETERS; RELIABILITY; SELECTIVE INVERSION RECOVERY; SIGNAL NOISE RATIO; STEADY STATE; VOLUNTEER; WHITE MATTER;

EID: 84867584676     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2012.08.047     Document Type: Article
Times cited : (58)

References (50)
  • 2
    • 27644564737 scopus 로고    scopus 로고
    • Characterization of the NMR behavior of white matter in bovine brain
    • Bjarnason T., Vavasour I., Chia C., Mackay A. Characterization of the NMR behavior of white matter in bovine brain. Magn. Reson. Med. 2005, 54:1072-1081.
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1072-1081
    • Bjarnason, T.1    Vavasour, I.2    Chia, C.3    Mackay, A.4
  • 3
    • 8144222223 scopus 로고    scopus 로고
    • A study of bipolar disorder using magnetization transfer imaging and voxel-based morphometry
    • Bruno S.D., Barker G.J., Cercignani M., Symms M., Ron M.A. A study of bipolar disorder using magnetization transfer imaging and voxel-based morphometry. Brain 2004, 127:2433-2440.
    • (2004) Brain , vol.127 , pp. 2433-2440
    • Bruno, S.D.1    Barker, G.J.2    Cercignani, M.3    Symms, M.4    Ron, M.A.5
  • 5
    • 33749165411 scopus 로고    scopus 로고
    • Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI
    • Cercignani M., Alexander D. Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI. Magn. Reson. Med. 2006, 56:803-810.
    • (2006) Magn. Reson. Med. , vol.56 , pp. 803-810
    • Cercignani, M.1    Alexander, D.2
  • 6
    • 0026467251 scopus 로고
    • The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI
    • Constable R.T., Gore J.C. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn. Reson. Med. 1992, 28:9-24.
    • (1992) Magn. Reson. Med. , vol.28 , pp. 9-24
    • Constable, R.T.1    Gore, J.C.2
  • 8
    • 0026526861 scopus 로고
    • Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging
    • Dousset V., Grossman R.I., Ramer K.N., Schnall M.D., Young L.H., Gonzalez-Scarano F., Lavi E., Cohen J.A. Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging. Radiology 1992, 182:483-491.
    • (1992) Radiology , vol.182 , pp. 483-491
    • Dousset, V.1    Grossman, R.I.2    Ramer, K.N.3    Schnall, M.D.4    Young, L.H.5    Gonzalez-Scarano, F.6    Lavi, E.7    Cohen, J.A.8
  • 9
    • 0017576498 scopus 로고
    • Cross relaxation and spin diffusion in the proton NMR or hydrated collagen
    • Edzes H.T., Samulski E.T. Cross relaxation and spin diffusion in the proton NMR or hydrated collagen. Nature 1977, 265:521-523.
    • (1977) Nature , vol.265 , pp. 521-523
    • Edzes, H.T.1    Samulski, E.T.2
  • 10
    • 4944228079 scopus 로고    scopus 로고
    • Magnetization transfer magnetic resonance imaging in the assessment of neurological diseases
    • Filippi M., Rocca M.A. Magnetization transfer magnetic resonance imaging in the assessment of neurological diseases. J. Neuroimaging 2004, 14:303-313.
    • (2004) J. Neuroimaging , vol.14 , pp. 303-313
    • Filippi, M.1    Rocca, M.A.2
  • 11
    • 77953706722 scopus 로고    scopus 로고
    • Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging
    • Garcia M., Gloor M., Wetzel S.G., Radue E.-W., Scheffler K., Bieri O. Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging. NeuroImage 2010, 52:532-537.
    • (2010) NeuroImage , vol.52 , pp. 532-537
    • Garcia, M.1    Gloor, M.2    Wetzel, S.G.3    Radue, E.-W.4    Scheffler, K.5    Bieri, O.6
  • 13
    • 51449112832 scopus 로고    scopus 로고
    • Quantitative magnetization transfer imaging using balanced SSFP
    • Gloor M., Scheffler K., Bieri O. Quantitative magnetization transfer imaging using balanced SSFP. Magn. Reson. Med. 2008, 60:691-700.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 691-700
    • Gloor, M.1    Scheffler, K.2    Bieri, O.3
  • 14
    • 33846809386 scopus 로고    scopus 로고
    • Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times
    • Gochberg D., Gore J. Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times. Magn. Reson. Med. 2007, 57:437-441.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 437-441
    • Gochberg, D.1    Gore, J.2
  • 18
    • 0036338719 scopus 로고    scopus 로고
    • Magnetization transfer ratio in mild cognitive impairment and dementia of Alzheimer's type
    • Kabani N.J., Sled J.G., Chertkow H. Magnetization transfer ratio in mild cognitive impairment and dementia of Alzheimer's type. NeuroImage 2002, 15:604-610.
    • (2002) NeuroImage , vol.15 , pp. 604-610
    • Kabani, N.J.1    Sled, J.G.2    Chertkow, H.3
  • 19
    • 0036136582 scopus 로고    scopus 로고
    • Regional magnetization transfer ratio changes in mild cognitive impairment
    • Kabani N.J., Sled J.G., Shuper A., Chertkow H. Regional magnetization transfer ratio changes in mild cognitive impairment. Magn. Reson. Med. 2002, 47:143-148.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 143-148
    • Kabani, N.J.1    Sled, J.G.2    Shuper, A.3    Chertkow, H.4
  • 21
    • 0016692549 scopus 로고
    • Tissue water content and nuclear magnetic resonance in normal and tumor tissues
    • Kiricuta I.C., Simplaceanu V. Tissue water content and nuclear magnetic resonance in normal and tumor tissues. Cancer Res. 1975, 35:1164-1167.
    • (1975) Cancer Res. , vol.35 , pp. 1164-1167
    • Kiricuta, I.C.1    Simplaceanu, V.2
  • 22
    • 0025738684 scopus 로고
    • Cholesterol of myelin is the determinant of gray-white contrast in MRI of brain
    • Koenig S.H. Cholesterol of myelin is the determinant of gray-white contrast in MRI of brain. Magn. Reson. Med. 1991, 20:285-291.
    • (1991) Magn. Reson. Med. , vol.20 , pp. 285-291
    • Koenig, S.H.1
  • 23
    • 0027934928 scopus 로고
    • Relaxivity and magnetization transfer of white matter lipids at MR imaging: importance of cerebrosides and pH
    • Kucharczyk W., Macdonal P., Stanisz G., Henkelman R. Relaxivity and magnetization transfer of white matter lipids at MR imaging: importance of cerebrosides and pH. Radiology 1994, 192:521-529.
    • (1994) Radiology , vol.192 , pp. 521-529
    • Kucharczyk, W.1    Macdonal, P.2    Stanisz, G.3    Henkelman, R.4
  • 24
    • 80051693255 scopus 로고    scopus 로고
    • Iterative optimization method for design of quantitative magnetization transfer imaging experiments
    • Levesque I.R., Sled J.G., Pike G.B. Iterative optimization method for design of quantitative magnetization transfer imaging experiments. Magn. Reson. Med. 2011, 66:635-643.
    • (2011) Magn. Reson. Med. , vol.66 , pp. 635-643
    • Levesque, I.R.1    Sled, J.G.2    Pike, G.B.3
  • 27
    • 0029353626 scopus 로고
    • Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir
    • Morrison C., Stanisz G., Henkelman R.M. Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir. J. Magn. Reson. B 1995, 108:103-113.
    • (1995) J. Magn. Reson. B , vol.108 , pp. 103-113
    • Morrison, C.1    Stanisz, G.2    Henkelman, R.M.3
  • 28
    • 70349972122 scopus 로고    scopus 로고
    • Magnetization transfer phenomenon in the human brain at 7 T
    • Mougin O.E., Coxon R.C., Pitiot A., Gowland P.A. Magnetization transfer phenomenon in the human brain at 7 T. NeuroImage 2010, 49:272-281.
    • (2010) NeuroImage , vol.49 , pp. 272-281
    • Mougin, O.E.1    Coxon, R.C.2    Pitiot, A.3    Gowland, P.A.4
  • 29
    • 0025034429 scopus 로고
    • Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE)
    • Mugler J.P., Brookeman J.R. Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn. Reson. Med. 1990, 15:152-157.
    • (1990) Magn. Reson. Med. , vol.15 , pp. 152-157
    • Mugler, J.P.1    Brookeman, J.R.2
  • 30
    • 23844436002 scopus 로고    scopus 로고
    • MR properties of excised neural tissue following experimentally induced clemyelination
    • Odrobina E., Lam T., Pun T., Midha R., Stanisz G. MR properties of excised neural tissue following experimentally induced clemyelination. NMR Biomed. 2005, 18:277-284.
    • (2005) NMR Biomed. , vol.18 , pp. 277-284
    • Odrobina, E.1    Lam, T.2    Pun, T.3    Midha, R.4    Stanisz, G.5
  • 31
    • 68149124496 scopus 로고    scopus 로고
    • The MT pool size ratio and the DTI radial diffusivity may reflect the myelination in shiverer and control mice
    • Ou X., Sun S.W., Liang H.F., Song S.K., Gochberg D.F. The MT pool size ratio and the DTI radial diffusivity may reflect the myelination in shiverer and control mice. NMR Biomed. 2009, 22:480-487.
    • (2009) NMR Biomed. , vol.22 , pp. 480-487
    • Ou, X.1    Sun, S.W.2    Liang, H.F.3    Song, S.K.4    Gochberg, D.F.5
  • 32
    • 0029993273 scopus 로고    scopus 로고
    • Pulsed magnetization transfer contrast in gradient echo imaging: a two-pool analytic description of signal response
    • Pike G.B. Pulsed magnetization transfer contrast in gradient echo imaging: a two-pool analytic description of signal response. Magn. Reson. Med. 1996, 36:95-103.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 95-103
    • Pike, G.B.1
  • 33
    • 34547815272 scopus 로고    scopus 로고
    • Modeling pulsed magnetization transfer
    • Portnoy S., Stanisz G.J. Modeling pulsed magnetization transfer. Magn. Reson. Med. 2007, 58:144-155.
    • (2007) Magn. Reson. Med. , vol.58 , pp. 144-155
    • Portnoy, S.1    Stanisz, G.J.2
  • 34
    • 0036999133 scopus 로고    scopus 로고
    • Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times
    • Ramani A., Dalton C., Miller D.H., Tofts P.S., Barker G.J. Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times. Magn. Reson. Imaging 2002, 20:721-731.
    • (2002) Magn. Reson. Imaging , vol.20 , pp. 721-731
    • Ramani, A.1    Dalton, C.2    Miller, D.H.3    Tofts, P.S.4    Barker, G.J.5
  • 36
    • 4444310685 scopus 로고    scopus 로고
    • Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain
    • Schmierer K., Scaravilli F., Altmann D., Barker G., Miller D. Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain. Ann. Neurol. 2004, 56:407-415.
    • (2004) Ann. Neurol. , vol.56 , pp. 407-415
    • Schmierer, K.1    Scaravilli, F.2    Altmann, D.3    Barker, G.4    Miller, D.5
  • 38
    • 0034218960 scopus 로고    scopus 로고
    • Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences
    • Sled J.G., Pike G.B. Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences. J. Magn. Reson. 2000, 145:24-36.
    • (2000) J. Magn. Reson. , vol.145 , pp. 24-36
    • Sled, J.G.1    Pike, G.B.2
  • 39
    • 0034759242 scopus 로고    scopus 로고
    • Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
    • Sled J.G., Pike G.B. Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI. Magn. Reson. Med. 2001, 46:923-931.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 923-931
    • Sled, J.G.1    Pike, G.B.2
  • 41
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction
    • Smith S.M. Fast robust automated brain extraction. Hum. Brain Mapp. 2002, 17:143-155.
    • (2002) Hum. Brain Mapp. , vol.17 , pp. 143-155
    • Smith, S.M.1
  • 42
    • 60349128515 scopus 로고    scopus 로고
    • Quantitative magnetization transfer characteristics of the human cervical spinal cord in vivo: application to adrenomyeloneuropathy
    • Smith S., Golay X., Fatemi A., Mahmood A., Raymond G., Moser H., van Zijl P., Stanisz G. Quantitative magnetization transfer characteristics of the human cervical spinal cord in vivo: application to adrenomyeloneuropathy. Magn. Reson. Med. 2009, 61:22-27.
    • (2009) Magn. Reson. Med. , vol.61 , pp. 22-27
    • Smith, S.1    Golay, X.2    Fatemi, A.3    Mahmood, A.4    Raymond, G.5    Moser, H.6    van Zijl, P.7    Stanisz, G.8
  • 44
    • 67651064318 scopus 로고    scopus 로고
    • Direct quantitative comparison between cross-relaxation imaging and diffusion tensor imaging of the human brain at 3.0 T
    • Underhill H.R., Yuan C., Yarnykh V.L. Direct quantitative comparison between cross-relaxation imaging and diffusion tensor imaging of the human brain at 3.0 T. NeuroImage 2009, 47:1568-1578.
    • (2009) NeuroImage , vol.47 , pp. 1568-1578
    • Underhill, H.R.1    Yuan, C.2    Yarnykh, V.L.3
  • 45
    • 78650187491 scopus 로고    scopus 로고
    • Fast bound pool fraction imaging of the in vivo rat brain: association with myelin content and validation in the C6 glioma model
    • Underhill H.R., Rostomily R.C., Mikheev A.M., Yuan C., Yarnykh V.L. Fast bound pool fraction imaging of the in vivo rat brain: association with myelin content and validation in the C6 glioma model. NeuroImage 2011, 54:2052-2065.
    • (2011) NeuroImage , vol.54 , pp. 2052-2065
    • Underhill, H.R.1    Rostomily, R.C.2    Mikheev, A.M.3    Yuan, C.4    Yarnykh, V.L.5
  • 46
    • 0031221119 scopus 로고    scopus 로고
    • Alignment by maximization of mutual information
    • Viola P., Wells W.M. Alignment by maximization of mutual information. Int. J. Comput. Vis. 1997, 24:137-154.
    • (1997) Int. J. Comput. Vis. , vol.24 , pp. 137-154
    • Viola, P.1    Wells, W.M.2
  • 47
    • 0024573913 scopus 로고
    • Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
    • Wolff S.D., Balaban R.S. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 1989, 10:135-144.
    • (1989) Magn. Reson. Med. , vol.10 , pp. 135-144
    • Wolff, S.D.1    Balaban, R.S.2
  • 49
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnykh V.L. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn. Reson. Med. 2007, 57:192-200.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 192-200
    • Yarnykh, V.L.1
  • 50
    • 4344697166 scopus 로고    scopus 로고
    • Cross-relaxation imaging reveals detailed anatomy of white matter fiber tracts in the human brain
    • Yarnykh V.L., Yuan C. Cross-relaxation imaging reveals detailed anatomy of white matter fiber tracts in the human brain. NeuroImage 2004, 23:409-424.
    • (2004) NeuroImage , vol.23 , pp. 409-424
    • Yarnykh, V.L.1    Yuan, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.