-
2
-
-
0002197407
-
Theory of earth heat exchangers for the heat pump
-
L.R. Ingersoll, F.T. Adler, H.J. Plass, and A.C. Ingersoll Theory of earth heat exchangers for the heat pump Heating, Piping & Air Conditioning 1950 113 122
-
(1950)
Heating, Piping & Air Conditioning
, pp. 113-122
-
-
Ingersoll, L.R.1
Adler, F.T.2
Plass, H.J.3
Ingersoll, A.C.4
-
3
-
-
70350364874
-
Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes
-
M. Philippe, M. Bernier, and D. Marchio Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes Geothermics 38 2009 407 413
-
(2009)
Geothermics
, vol.38
, pp. 407-413
-
-
Philippe, M.1
Bernier, M.2
Marchio, D.3
-
4
-
-
0033309869
-
A short time step response factor model for vertical ground loop heat exchangers
-
C. Yavuzturk, and J.D. Spitler A short time step response factor model for vertical ground loop heat exchangers ASHRAE Transactions 105 1999 475 485
-
(1999)
ASHRAE Transactions
, vol.105
, pp. 475-485
-
-
Yavuzturk, C.1
Spitler, J.D.2
-
5
-
-
70349437017
-
Vertical-borehole ground-coupled heat pumps: A review of models and systems
-
H. Yang, P. Cui, and Z. Fang Vertical-borehole ground-coupled heat pumps: a review of models and systems Applied Energy 87 2010 16 27
-
(2010)
Applied Energy
, vol.87
, pp. 16-27
-
-
Yang, H.1
Cui, P.2
Fang, Z.3
-
6
-
-
33746469117
-
Implementation and validation of ground-source heat pump system models in an integrated building and system simulation environment
-
Building Performance Simulation
-
D.E. Fisher, S.J. Rees, S.K. Padhmanabhan, and A. Murugappan Implementation and validation of ground-source heat pump system models in an integrated building and system simulation environment HVAC&R Research 12 2006 693 710 (Pubitemid 44123416)
-
(2006)
HVAC and R Research
, vol.12
, Issue.3 A
, pp. 693-710
-
-
Fisher, D.E.1
Rees, S.J.2
Padhmanabhan, S.K.3
Murugappan, A.4
-
8
-
-
0034825490
-
Field validation of a short time step model for vertical ground-loop heat exchangers
-
C. Yavuzturk, and J.D. Spitler Field validation of a short time step model for vertical ground-loop heat exchangers ASHRAE Transactions 107 2001 751 759
-
(2001)
ASHRAE Transactions
, vol.107
, pp. 751-759
-
-
Yavuzturk, C.1
Spitler, J.D.2
-
9
-
-
0040417715
-
The Laplace transformation: Problems on the cylinder and sphere
-
Oxford University Press Oxford University Oxford
-
H.S. Carslaw, and J.C. Jaeger The Laplace transformation: problems on the cylinder and sphere Oxford University Press Conduction of Heat in Solids 1946 Oxford University Oxford 327 352
-
(1946)
Conduction of Heat in Solids
, pp. 327-352
-
-
Carslaw, H.S.1
Jaeger, J.C.2
-
11
-
-
0034832568
-
Ground-coupled heat pump system simulation
-
M.A. Bernier Ground-coupled heat pump system simulation ASHRAE Transactions 107 2001 605 616 (Pubitemid 32861202)
-
(2001)
ASHRAE Transactions
, vol.107
, Issue.PART 1
, pp. 605-616
-
-
Bernier, M.A.1
-
12
-
-
0242628916
-
Minimum duration of in-situ tests on vertical boreholes
-
R.A. Beier, and M.D. Smith Minimum duration of in-situ tests on vertical boreholes ASHRAE Transactions 109 2003 475 486
-
(2003)
ASHRAE Transactions
, vol.109
, pp. 475-486
-
-
Beier, R.A.1
Smith, M.D.2
-
13
-
-
84976835846
-
Algorithm 368, numerical inversion of the Laplace transfroms [D5]
-
H. Stehfest Algorithm 368, numerical inversion of the Laplace transfroms [D5] Communications of the ACM 13 1970 47 49
-
(1970)
Communications of the ACM
, vol.13
, pp. 47-49
-
-
Stehfest, H.1
-
14
-
-
84871752069
-
A new approach to modeling ground heat exchangers in the initial phase of heat-flux build up
-
G. Bandyopadhyay, M. Kulkarni, and M. Mann A new approach to modeling ground heat exchangers in the initial phase of heat-flux build up ASHRAE Transactions 114 2008 428 439
-
(2008)
ASHRAE Transactions
, vol.114
, pp. 428-439
-
-
Bandyopadhyay, G.1
Kulkarni, M.2
Mann, M.3
-
15
-
-
48949115133
-
Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers
-
G. Bandyopadhyay, W. Gosnold, and M. Mann Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers Energy and Buildings 40 2008 1816 1824
-
(2008)
Energy and Buildings
, vol.40
, pp. 1816-1824
-
-
Bandyopadhyay, G.1
Gosnold, W.2
Mann, M.3
-
16
-
-
33846904538
-
New solutions for the short-time analysis of geothermal vertical boreholes
-
DOI 10.1016/j.ijheatmasstransfer.2006.09.007, PII S0017931006005308
-
L. Lamarche, and B. Beauchamp New solutions for the short-time analysis of geothermal vertical boreholes International Journal of Heat and Mass Transfer 50 2007 1408 1419 (Pubitemid 46241147)
-
(2007)
International Journal of Heat and Mass Transfer
, vol.50
, Issue.7-8
, pp. 1408-1419
-
-
Lamarche, L.1
Beauchamp, B.2
-
17
-
-
82055186255
-
New analytical and numerical solutions for the short-term analysis of vertical ground heat exchangers
-
S. Javed, and J. Claesson New analytical and numerical solutions for the short-term analysis of vertical ground heat exchangers ASHRAE Transactions 117 2011 3 12
-
(2011)
ASHRAE Transactions
, vol.117
, pp. 3-12
-
-
Javed, S.1
Claesson, J.2
-
18
-
-
84855590814
-
Vertical ground heat exchangers: A review of heat flow models
-
Effstock 2009, Stockholm, Sweden
-
S. Javed, P. Fahlén, J. Claesson, Vertical ground heat exchangers: A review of heat flow models, in: Proceedings of the 11th International Conference on Thermal Energy Storage, Effstock 2009, Stockholm, Sweden (2009).
-
(2009)
Proceedings of the 11th International Conference on Thermal Energy Storage
-
-
S. Javed1
-
19
-
-
84871726365
-
Analytical modelling of short-term response of ground heat exchangers in ground source heat pump systems
-
Antalya Turkey
-
S. Javed, J. Claesson, P. Fahlén, Analytical modelling of short-term response of ground heat exchangers in ground source heat pump systems, in: Proceedings of the 10th REHVA World Congress, Clima 2010, Antalya Turkey (2010).
-
(2010)
Proceedings of the 10th REHVA World Congress, Clima 2010
-
-
S. Javed1
-
20
-
-
0036870964
-
A finite line-source model for boreholes in geothermal heat exchangers
-
DOI 10.1002/htj.10057
-
H.Y. Zeng, N.R. Diao, and Z.H. Fang A finite line-source model for boreholes in geothermal heat exchangers Heat Transfer-Asian Research 31 2002 558 567 (Pubitemid 36065091)
-
(2002)
Heat Transfer - Asian Research
, vol.31
, Issue.7
, pp. 558-567
-
-
Zeng, H.Y.1
Diao, N.R.2
Fang, Z.H.3
-
21
-
-
33845742563
-
A new contribution to the finite line-source model for geothermal boreholes
-
DOI 10.1016/j.enbuild.2006.06.003, PII S0378778806001824
-
L. Lamarche, and B. Beauchamp A new contribution to the finite line-source model for geothermal boreholes Energy and Buildings 39 2007 188 198 (Pubitemid 46014389)
-
(2007)
Energy and Buildings
, vol.39
, Issue.2
, pp. 188-198
-
-
Lamarche, L.1
Beauchamp, B.2
-
22
-
-
67349142620
-
A fast algorithm for the hourly simulations of ground-source heat pumps using arbitrary response factors
-
L. Lamarche A fast algorithm for the hourly simulations of ground-source heat pumps using arbitrary response factors Renewable Energy 34 2009 2252 2258
-
(2009)
Renewable Energy
, vol.34
, pp. 2252-2258
-
-
Lamarche, L.1
-
23
-
-
79953730749
-
The temperature penalty approach to the design of borehole heat exchangers for heat pump applications
-
M. Fossa The temperature penalty approach to the design of borehole heat exchangers for heat pump applications Energy and Buildings 43 2011 1473 1479
-
(2011)
Energy and Buildings
, vol.43
, pp. 1473-1479
-
-
Fossa, M.1
-
24
-
-
67349092040
-
Finite line-source model for borehole heat exchangers: Effect of vertical temperature variations
-
T.V. Bandos, Á. Montero, E. Fernández, J.L.G. Santander, J.M. Isidro, J. Pérez, P.J. Fernández de Córdoba, and J.F. Urchueguía Finite line-source model for borehole heat exchangers: effect of vertical temperature variations Geothermics 38 2009 263 270
-
(2009)
Geothermics
, vol.38
, pp. 263-270
-
-
Bandos, T.V.1
Montero, Á.2
Fernández, E.3
Santander, J.L.G.4
Isidro, J.M.5
Pérez, J.6
Fernández De Córdoba, P.J.7
Urchueguía, J.F.8
-
25
-
-
79955982919
-
Improving parameter estimates obtained from thermal response tests: Effect of ambient air temperature variations
-
T.V. Bandos, Á. Montero, P.J. Fernández de Córdoba, and J.F. Urchueguía Improving parameter estimates obtained from thermal response tests: effect of ambient air temperature variations Geothermics 40 2011 136 143
-
(2011)
Geothermics
, vol.40
, pp. 136-143
-
-
Bandos, T.V.1
Montero, Á.2
Fernández De Córdoba, P.J.3
Urchueguía, J.F.4
-
26
-
-
84856669991
-
An analytical method to calculate borehole fluid temperatures for time-scales from minutes to decades
-
J. Claesson, and S. Javed An analytical method to calculate borehole fluid temperatures for time-scales from minutes to decades ASHRAE Transactions 117 2011 279 288
-
(2011)
ASHRAE Transactions
, vol.117
, pp. 279-288
-
-
Claesson, J.1
Javed, S.2
-
27
-
-
0042830430
-
Heat transfer analysis of boreholes in vertical ground heat exchangers
-
DOI 10.1016/S0017-9310(03)00270-9
-
H.Y. Zeng, N.R. Diao, and Z. Fang Heat transfer analysis of boreholes in vertical ground heat exchangers International Journal of Heat and Mass Transfer 46 2003 4467 4481 (Pubitemid 37036256)
-
(2003)
International Journal of Heat and Mass Transfer
, vol.46
, Issue.23
, pp. 4467-4481
-
-
Zeng, H.1
Diao, N.2
Fang, Z.3
-
28
-
-
79960914937
-
Coupling of geothermal heat pumps with thermal solar collectore using double U-tube boreholes with two independent circuits
-
P. Eslami-Nejad, and M. Bernier Coupling of geothermal heat pumps with thermal solar collectore using double U-tube boreholes with two independent circuits Applied Thermal Engineering 31 2011 3066 3077
-
(2011)
Applied Thermal Engineering
, vol.31
, pp. 3066-3077
-
-
Eslami-Nejad, P.1
Bernier, M.2
-
29
-
-
79959818795
-
Feasibility study on novel hybrid ground coupled heat pump system with nocturnal cooling radiator for cooling load dominated buildings
-
Y. Man, H. Yang, J.D. Spitler, and Z. Fang Feasibility study on novel hybrid ground coupled heat pump system with nocturnal cooling radiator for cooling load dominated buildings Applied Energy 88 2011 4160 4171
-
(2011)
Applied Energy
, vol.88
, pp. 4160-4171
-
-
Man, Y.1
Yang, H.2
Spitler, J.D.3
Fang, Z.4
-
30
-
-
33847205395
-
Transient heat conduction from a vertical rod buried in a semi-infinite medium with variable heating strength
-
X. Duan, G.F. Naterer, M. Lu, and W. Mueller Transient heat conduction from a vertical rod buried in a semi-infinite medium with variable heating strength Heat and Mass Transfer 43 2007 547 557
-
(2007)
Heat and Mass Transfer
, vol.43
, pp. 547-557
-
-
Duan, X.1
Naterer, G.F.2
Lu, M.3
Mueller, W.4
-
31
-
-
38849136090
-
Ground thermal response to heat conduction in a power transmission tower foundation
-
DOI 10.1007/s00231-007-0282-3
-
X. Duan, and G.F. Naterer Ground thermal response to heat conduction in a power transmission tower foundation Heat and Mass Transfer 44 2008 547 558 (Pubitemid 351191452)
-
(2008)
Heat and Mass Transfer/Waerme- und Stoffuebertragung
, vol.44
, Issue.5
, pp. 547-558
-
-
Duan, X.1
Naterer, G.F.2
-
32
-
-
59049093874
-
Ground heat transfer from a varying line source with seasonal temperature fluctuations
-
X. Duan, and G.F. Naterer Ground heat transfer from a varying line source with seasonal temperature fluctuations Journal of Heat Transfer 130 2008 1 10
-
(2008)
Journal of Heat Transfer
, vol.130
, pp. 1-10
-
-
Duan, X.1
Naterer, G.F.2
-
35
-
-
56949090953
-
Fast fluid and ground temperature computation for geothermal ground-loop heat exchanger systems
-
D. Marcotte, and P. Pasquier Fast fluid and ground temperature computation for geothermal ground-loop heat exchanger systems Geothermics 37 2008 651 665
-
(2008)
Geothermics
, vol.37
, pp. 651-665
-
-
Marcotte, D.1
Pasquier, P.2
-
36
-
-
84871752594
-
Extracted heat from geothermal boreholes: Where does the energy come from?
-
Toronto, Ontario
-
H.-F. Nouanegue, A.S. Shirazi, M. Bernier, Extracted heat from geothermal boreholes: where does the energy come from? in: 4th Canadian Solar Buildings Conference, Toronto, Ontario (2009) pp. 227-236.
-
(2009)
4th Canadian Solar Buildings Conference
, pp. 227-236
-
-
Nouanegue, H.-F.1
Shirazi, A.S.2
Bernier, M.3
-
37
-
-
84871745764
-
Utilisation des g-functions de Eskilson pour la simulation de systèmes géothermiques
-
Halifax, NS
-
M. Cimmino, M. Bernier, P. Pasquier, Utilisation des g-functions de Eskilson pour la simulation de systèmes géothermiques, in: Proccedings of aSim 2012, Halifax, NS (2012) pp. 282-295.
-
(2012)
Proccedings of ASim 2012
, pp. 282-295
-
-
Cimmino, M.1
Bernier, M.2
Pasquier, P.3
-
38
-
-
7244233029
-
A multiple load aggregation algorithm for annual hourly simulations of GCHP systems
-
M.A. Bernier, P. Pinel, R. Labib, and R. Paillot A multiple load aggregation algorithm for annual hourly simulations of GCHP systems HVAC&R Research 10 2004 471 487
-
(2004)
HVAC&R Research
, vol.10
, pp. 471-487
-
-
Bernier, M.A.1
Pinel, P.2
Labib, R.3
Paillot, R.4
-
39
-
-
54049093563
-
Implementation of the numerical Laplace transform: A review
-
P. Moreno, and A. Ramirez Implementation of the numerical Laplace transform: a review IEEE Transactions on Power Delivery 23 2008 2599 2609
-
(2008)
IEEE Transactions on Power Delivery
, vol.23
, pp. 2599-2609
-
-
Moreno, P.1
Ramirez, A.2
-
40
-
-
0020937841
-
Power system transients: Errors incurred in the numerical inversion of the laplace transform
-
L.M. Wedepohl, Power system transients: errors incurred in the numerical inversion of the Laplace transforms, in: 26th Midwest Symposium on Circuits and Systems, Mexico (1983) pp. 174-178. (Pubitemid 14499474)
-
(1983)
Midwest Symposium on Circuits and Systems
, pp. 174-178
-
-
Wedepohl, L.M.1
|