The effect of basic assumptions on the tissue oxygen saturation value of near infrared spectroscopy

Author keywords

Absorption coefficient; Methodology; Near infrared spectroscopy; Tissue oxygen saturation

Indexed keywords

ADULT; ASSUMPTION; BETWEEN SUBJECT VARIABILITY; BODY MASS; CONFERENCE PAPER; CONTROLLED STUDY; DIFFUSION COEFFICIENT; FOREARM; HEAD; HUMAN; HUMAN TISSUE; INFANT; LIPID ANALYSIS; MALE; NEAR INFRARED SPECTROSCOPY; NEWBORN; OXYGEN SATURATION; PRIORITY JOURNAL; STATISTICAL CONCEPTS; STATISTICAL PARAMETERS; TISSUE OXYGEN SATURATION; WATER TERM; WITHIN SUBJECT VARIABILITY; ABSORPTION; ALGORITHM; TISSUE OXYGENATION;

EID: 84867542530     PISSN: 00652598     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-1-4614-4989-8_24     Document Type: Conference Paper
Times cited : (20)

References (15)
  • 1
    • 0033321556 scopus 로고    scopus 로고
    • New optical probe designs for absolute (selfcalibrating) NIR tissue hemoglobin measurements
    • Hueber DM, Fantini S, Cerussi AE et al (1999) New optical probe designs for absolute (selfcalibrating) NIR tissue hemoglobin measurements. Proc SPIE 3597:618-631
    • (1999) Proc SPIE , vol.3597 , pp. 618-631
    • Hueber, D.M.1    Fantini, S.2    Cerussi, A.E.3
  • 2
    • 85018149579 scopus 로고
    • Absolute quanti fi cation methods in tissue near infrared spectroscopy
    • Matcher SJ, Kirkpatrick P, Nahid K et al (1995) Absolute quanti fi cation methods in tissue near infrared spectroscopy. Proc SPIE 2359:486-495
    • (1995) Proc SPIE , vol.2359 , pp. 486-495
    • Matcher, S.J.1    Kirkpatrick, P.2    Nahid, K.3
  • 3
    • 51249118472 scopus 로고    scopus 로고
    • Monitoring neonatal regional cerebral oxygen saturation in clinical practice: Value and pitfalls
    • van Bel F, Lemmers P, Naulaers G (2008) Monitoring neonatal regional cerebral oxygen saturation in clinical practice: value and pitfalls. Neonatology 94(4):237-244
    • (2008) Neonatology , vol.94 , Issue.4 , pp. 237-244
    • Van Bel, F.1    Lemmers, P.2    Naulaers, G.3
  • 4
    • 70450203913 scopus 로고    scopus 로고
    • Advances in near-infrared spectroscopy to study the brain of the preterm and term neonate
    • Wolf M, Greisen G (2009) Advances in near-infrared spectroscopy to study the brain of the preterm and term neonate. Clin Perinatol 36(4):807-834
    • (2009) Clin Perinatol , vol.36 , Issue.4 , pp. 807-834
    • Wolf, M.1    Greisen, G.2
  • 5
    • 0033339492 scopus 로고    scopus 로고
    • A tissue oxygenation monitor using NIR spatially resolved spectroscopy
    • Suzuki S, Takasaki S, Ozaki T et al (1999) A tissue oxygenation monitor using NIR spatially resolved spectroscopy. Proc SPIE 3597:582-592
    • (1999) Proc SPIE , vol.3597 , pp. 582-592
    • Suzuki, S.1    Takasaki, S.2    Ozaki, T.3
  • 6
    • 0031054454 scopus 로고    scopus 로고
    • A comparison of the Invos 3100 and the Critikon 2020 near-infrared spectrophotometers as monitors of cerebral oxygenation
    • McKeating EG, Monjardino JR, Signorini DF et al (1997) A comparison of the Invos 3100 and the Critikon 2020 near-infrared spectrophotometers as monitors of cerebral oxygenation. Anaesthesia 52(2):136-140
    • (1997) Anaesthesia , vol.52 , Issue.2 , pp. 136-140
    • McKeating, E.G.1    Monjardino, J.R.2    Signorini, D.F.3
  • 7
    • 0036796709 scopus 로고    scopus 로고
    • A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 Near-Infrared Spectrophotometers
    • Thavasothy M, Broadhead M, Elwell C et al (2002) A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 Near-Infrared Spectrophotometers. Anaesthesia 57(10):999-1006
    • (2002) Anaesthesia , vol.57 , Issue.10 , pp. 999-1006
    • Thavasothy, M.1    Broadhead, M.2    Elwell, C.3
  • 8
    • 0036183566 scopus 로고    scopus 로고
    • A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers
    • Yoshitani K, Kawaguchi M, Tatsumi K et al (2002) A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers. Anesth Analg 94(3):586-590
    • (2002) Anesth Analg , vol.94 , Issue.3 , pp. 586-590
    • Yoshitani, K.1    Kawaguchi, M.2    Tatsumi, K.3
  • 9
    • 80052534793 scopus 로고    scopus 로고
    • Reproducibility of cerebral tissue oxygenation saturation measurements by near infrared spectroscopy in newborn infants
    • Jenny C, Biallas M, Trajkovic I et al (2011) Reproducibility of cerebral tissue oxygenation saturation measurements by near infrared spectroscopy in newborn infants. J Biomed Opt 16(9): 097004
    • (2011) J Biomed Opt , vol.16 , Issue.9 , pp. 097004
    • Jenny, C.1    Biallas, M.2    Trajkovic, I.3
  • 10
    • 22744459940 scopus 로고    scopus 로고
    • New multichannel near infrared spectrophotometry system for functional studies of the brain in adults and neonates
    • Haensse D, Szabo P, Brown D et al (2005) New multichannel near infrared spectrophotometry system for functional studies of the brain in adults and neonates. Opt Express 13(12): 4525-4538
    • (2005) Opt Express , vol.13 , Issue.12 , pp. 4525-4538
    • Haensse, D.1    Szabo, P.2    Brown, D.3
  • 11
    • 47249124102 scopus 로고    scopus 로고
    • Wireless miniaturized in-vivo near infrared imaging
    • Muehlemann T, Haensse D, Wolf M (2008) Wireless miniaturized in-vivo near infrared imaging. Opt Express 16(14):10323-10330
    • (2008) Opt Express , vol.16 , Issue.14 , pp. 10323-10330
    • Muehlemann, T.1    Haensse, D.2    Wolf, M.3
  • 12
    • 0029060006 scopus 로고
    • Performance comparison of several published tissue near-infrared spectroscopy algorithms
    • Matcher SJ, Elwell CE, Cooper CE et al (1995) Performance comparison of several published tissue near-infrared spectroscopy algorithms. Anal Biochem 227(1):54-68
    • (1995) Anal Biochem , vol.227 , Issue.1 , pp. 54-68
    • Matcher, S.J.1    Elwell, C.E.2    Cooper, C.E.3
  • 13
    • 0001329554 scopus 로고    scopus 로고
    • In vivo measurements of the wavelength dependence of tissue-scattering coef fi cients between 760 and 900 nm measured with time-resolved spectroscopy
    • Matcher SJ, Cope M, Delpy DT (1997) In vivo measurements of the wavelength dependence of tissue-scattering coef fi cients between 760 and 900 nm measured with time-resolved spectroscopy. Appl Opt 36(1):386-396
    • (1997) Appl Opt , vol.36 , Issue.1 , pp. 386-396
    • Matcher, S.J.1    Cope, M.2    Delpy, D.T.3
  • 14
    • 80052523217 scopus 로고    scopus 로고
    • Precision of cerebral oxygenation and hemoglobin concentration measurements in neonates measured by near-infrared spectroscopy
    • Arri SJ, Muehlemann T, Biallas M et al (2011) Precision of cerebral oxygenation and hemoglobin concentration measurements in neonates measured by near-infrared spectroscopy. J Biomed Opt 16(4):047005
    • (2011) J Biomed Opt , vol.16 , Issue.4 , pp. 047005
    • Arri, S.J.1    Muehlemann, T.2    Biallas, M.3
  • 15
    • 0032765792 scopus 로고    scopus 로고
    • The in fl uence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom
    • Wolf M, Keel M, Dietz V et al (1999) The in fl uence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom. Phys Med Biol 44(7): 1743-1753
    • (1999) Phys Med Biol , vol.44 , Issue.7 , pp. 1743-1753
    • Wolf, M.1    Keel, M.2    Dietz, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.