Pacemaker lead extraction and recapture of venous access: Technical problems arising from extensive venous obstruction

Author keywords

Lead extraction; Lead related venous occlusion; Recapture of venous access

Indexed keywords

AGED; ANGIOGRAPHY; ARTICLE; ARTIFICIAL HEART PACEMAKER; BRACHIOCEPHALIC VEIN OBSTRUCTION; CASE REPORT; CAVA VEIN OBSTRUCTION; DEVICE REMOVAL; FEMALE; GUIDE WIRE; HUMAN; PACEMAKER ELECTRODE; REIMPLANTATION; SUBCLAVIAN VEIN OBSTRUCTION; SUPERIOR CAVA VEIN OBSTRUCTION; VASCULAR ACCESS; VEIN OCCLUSION;

EID: 84867510089     PISSN: 18975593     EISSN: None     Source Type: Journal    
DOI: 10.5603/CJ.2012.0093     Document Type: Article
Times cited : (13)

References (15)
  • 1
    • 0142240133 scopus 로고    scopus 로고
    • Symptomatic occlusion of the access vein after pacemaker or ICD lead extraction
    • Bracke FA, Meijer A, Van Gelder LM. Symptomatic occlusion of the access vein after pacemaker or ICD lead extraction. Heart, 2003; 89: 1348-1349.
    • (2003) Heart , vol.89 , pp. 1348-1349
    • Bracke, F.A.1    Meijer, A.2    van Gelder, L.M.3
  • 2
    • 0042701462 scopus 로고    scopus 로고
    • Venous occlusion of the access vein in patients referred for lead extraction: Influence of patient and lead characteristics
    • Bracke F, Meijer A, Van Gelder B. Venous occlusion of the access vein in patients referred for lead extraction: Influence of patient and lead characteristics. Pacing Clin Electrophysiol, 2003; 26: 1649-1652.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1649-1652
    • Bracke, F.1    Meijer, A.2    van Gelder, B.3
  • 4
    • 3042745792 scopus 로고    scopus 로고
    • Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement
    • Lickfett L, Bitzen A, Arepally A et al. Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace, 2004; 6: 25-31.
    • (2004) Europace , vol.6 , pp. 25-31
    • Lickfett, L.1    Bitzen, A.2    Arepally, A.3
  • 5
    • 0028844611 scopus 로고
    • Anatomical findings in patients having had a chronically indwelling coronary sinus defibrillation lead
    • Jones GK, Swerdlow C, Reichenbach DD et al. Anatomical findings in patients having had a chronically indwelling coronary sinus defibrillation lead. Pacing Clin Electrophysiol, 1995; 18: 2062-2067.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 2062-2067
    • Jones, G.K.1    Swerdlow, C.2    Reichenbach, D.D.3
  • 6
    • 0036380363 scopus 로고    scopus 로고
    • Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads
    • Esposito M, Kennergren C, Holmström N et al. Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads. J Biomed Mater Res, 2002; 63: 548-558.
    • (2002) J Biomed Mater Res , vol.63 , pp. 548-558
    • Esposito, M.1    Kennergren, C.2    Holmström, N.3
  • 7
    • 0141705179 scopus 로고    scopus 로고
    • Histologic changes in the human vein wall adjacent to indwelling central venous catheters
    • Forauer AR, Theoharis C. Histologic changes in the human vein wall adjacent to indwelling central venous catheters. J Vasc Interv Radiol, 2003; 14: 1163-1168.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1163-1168
    • Forauer, A.R.1    Theoharis, C.2
  • 8
    • 0032971951 scopus 로고    scopus 로고
    • Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    • Candinas R, Duru F, Schneider J et al. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads. Mayo Clin Proc, 1999; 74: 120-125.
    • (1999) Mayo Clin Proc , vol.74 , pp. 120-125
    • Candinas, R.1    Duru, F.2    Schneider, J.3
  • 9
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management
    • Heart Rhythm Society; American Heart Association, This document was endorsed by the American Heart Association (AHA)
    • Wilkoff BL, Love CJ, Byrd CL et al. Heart Rhythm Society; American Heart Association. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management. This document was endorsed by the American Heart Association (AHA). Heart Rhythm, 2009; 6: 1085-1104.
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3
  • 11
    • 50449086054 scopus 로고    scopus 로고
    • Implant venoplasty: Dilation of subclavian and coronary veins to facilitate device implantation: Indications, frequency, methods, and complications
    • Worley SJ. Implant venoplasty: Dilation of subclavian and coronary veins to facilitate device implantation: Indications, frequency, methods, and complications. J Cardiovasc Electrophysiol, 2008; 19: 1004-1007.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 1004-1007
    • Worley, S.J.1
  • 12
    • 0031292750 scopus 로고    scopus 로고
    • Extraction and replacement of permanent pacemaker leads through occluded vessels: Use of extraction sheaths as conduits: Balloon venoplasty as an adjunct
    • Pace JN, Maquilan M, Hessen SE et al. Extraction and replacement of permanent pacemaker leads through occluded vessels: use of extraction sheaths as conduits: Balloon venoplasty as an adjunct. J Interv Card Electrophysiol, 1997; 1: 271-279.
    • (1997) J Interv Card Electrophysiol , vol.1 , pp. 271-279
    • Pace, J.N.1    Maquilan, M.2    Hessen, S.E.3
  • 13
    • 3242662455 scopus 로고    scopus 로고
    • Reuse of occluded veins during permanent pacemaker lead extraction: A new indication for femoral Head extraction
    • Staniforth AD, Schilling RJ. Reuse of occluded veins during permanent pacemaker lead extraction: A new indication for femoral Head extraction. Indian Pacing Electrophysiol J, 2002; 2: 97-103.
    • (2002) Indian Pacing Electrophysiol J , vol.2 , pp. 97-103
    • Staniforth, A.D.1    Schilling, R.J.2
  • 14
    • 34547210134 scopus 로고    scopus 로고
    • Successful coronary sinus lead replacement despite total venous occlusion using femoral pull through, two operator counter-traction and subclavian venoplasty
    • Rogers DP, Lambiase PD, Chow AW. Successful coronary sinus lead replacement despite total venous occlusion using femoral pull through, two operator counter-traction and subclavian venoplasty. J Interv Card Electrophysiol, 2007; 19: 69-71.
    • (2007) J Interv Card Electrophysiol , vol.19 , pp. 69-71
    • Rogers, D.P.1    Lambiase, P.D.2    Chow, A.W.3
  • 15
    • 0036461560 scopus 로고    scopus 로고
    • Use of a laser sheath to obtain venous access in pacemaker lead-related obstruction without extraction of the lead
    • Bracke FA, Meijer A, van Gelder LM. Use of a laser sheath to obtain venous access in pacemaker lead-related obstruction without extraction of the lead. Europace, 2002; 4: 67-68.
    • (2002) Europace , vol.4 , pp. 67-68
    • Bracke, F.A.1    Meijer, A.2    van Gelder, L.M.3