메뉴 건너뛰기




Volumn 32, Issue 7, 2012, Pages 571-574

A three-dimensional stereoscopic monitor system in microscopic vascular anastomosis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERY ANASTOMOSIS; ARTICLE; CANCER SURGERY; CASE REPORT; DISPLAY SYSTEM; FREE TISSUE GRAFT; HEAD AND NECK CANCER; HUMAN; HYPOPHARYNX CANCER; IMAGE ANALYSIS; MALE; MICROSURGERY; MONITOR; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; STEREOMICROSCOPY; STEREOSCOPE; SURGEON; SURGICAL MICROSCOPE; THREE DIMENSIONAL IMAGING;

EID: 84867479208     PISSN: 07381085     EISSN: 10982752     Source Type: Journal    
DOI: 10.1002/micr.22035     Document Type: Article
Times cited : (18)

References (18)
  • 3
    • 34948845019 scopus 로고    scopus 로고
    • A new type of magnification system in free microvascular tissue transfer: Varioscope M5
    • Chiummariello S, Fioramonti P, Menichini G, Scuderi N, Alfano C,. A new type of magnification system in free microvascular tissue transfer: Varioscope M5. Microsurgery 2007; 27: 533-535.
    • (2007) Microsurgery , vol.27 , pp. 533-535
    • Chiummariello, S.1    Fioramonti, P.2    Menichini, G.3    Scuderi, N.4    Alfano, C.5
  • 4
    • 67649210461 scopus 로고    scopus 로고
    • Varioscope M5: A new type of magnification system in anterolateral thigh perforator free-flap surgery
    • Chiummariello S, Monarca C, Dessy LA, Alfano C, Scuderi N,. Varioscope M5: A new type of magnification system in anterolateral thigh perforator free-flap surgery. J Reconstr Microsurg 2009; 25: 227-231.
    • (2009) J Reconstr Microsurg , vol.25 , pp. 227-231
    • Chiummariello, S.1    Monarca, C.2    Dessy, L.A.3    Alfano, C.4    Scuderi, N.5
  • 5
    • 67649445914 scopus 로고    scopus 로고
    • Spinal neurosurgery with the head-mounted "varioscope" microscope
    • Kuchta J, Simons P,. Spinal neurosurgery with the head-mounted "Varioscope" microscope. Cent Eur Neurosurg 2009; 70: 98-100.
    • (2009) Cent Eur Neurosurg , vol.70 , pp. 98-100
    • Kuchta, J.1    Simons, P.2
  • 6
    • 67549086255 scopus 로고    scopus 로고
    • Stereoscopic virtual reality simulation for microsurgical excision of cerebral arteriovenous malformation: Case illustrations
    • discussion 72-63.
    • Wong GK, Zhu CX, Ahuja AT, Poon WS,. Stereoscopic virtual reality simulation for microsurgical excision of cerebral arteriovenous malformation: Case illustrations. Surg Neurol 2009; 72: 69-72; discussion 72-63.
    • (2009) Surg Neurol , vol.72 , pp. 69-72
    • Wong, G.K.1    Zhu, C.X.2    Ahuja, A.T.3    Poon, W.S.4
  • 8
    • 0038625158 scopus 로고    scopus 로고
    • Microsurgery simulators in virtual reality: Review
    • Erel E, Aiyenibe B, Butler PE,. Microsurgery simulators in virtual reality: Review. Microsurgery 2003; 23: 147-152.
    • (2003) Microsurgery , vol.23 , pp. 147-152
    • Erel, E.1    Aiyenibe, B.2    Butler, P.E.3
  • 9
    • 16844383661 scopus 로고    scopus 로고
    • Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography
    • discussion281-290.
    • Unsgaard G, Ommedal S, Rygh OM, Lindseth F,. Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography. Neurosurgery 2005; 56 (2 Suppl): 281-290; discussion281-290.
    • (2005) Neurosurgery , vol.56 , Issue.2 SUPPL. , pp. 281-290
    • Unsgaard, G.1    Ommedal, S.2    Rygh, O.M.3    Lindseth, F.4
  • 11
    • 0036295167 scopus 로고    scopus 로고
    • The development of three dimensional video microscope system for clinical application in neurosurgery
    • Seiki Y, Shibata I, Oishi H, Sanpei K, Kano T, Utagawa T, Fukuyo T,. The development of three dimensional video microscope system for clinical application in neurosurgery. No Shinkei Geka 2002; 30: 601-606.
    • (2002) No Shinkei Geka , vol.30 , pp. 601-606
    • Seiki, Y.1    Shibata, I.2    Oishi, H.3    Sanpei, K.4    Kano, T.5    Utagawa, T.6    Fukuyo, T.7
  • 13
    • 0035519072 scopus 로고    scopus 로고
    • Fabricating microretarders by CO2 laser heating process technology
    • Tsai CH, Huang KC, Lee KJ, Hsueh WJ,. Fabricating microretarders by CO2 laser heating process technology. Opt Eng 2001; 40: 2577-2581.
    • (2001) Opt Eng , vol.40 , pp. 2577-2581
    • Tsai, C.H.1    Huang, K.C.2    Lee, K.J.3    Hsueh, W.J.4
  • 14
    • 0031928117 scopus 로고    scopus 로고
    • Stereoscopic head-mounted display incorporated into microsurgical procedures: Technical note
    • discussion 395-396.
    • Levy ML, Chen JC, Moffitt K, Corber Z, McComb JG,. Stereoscopic head-mounted display incorporated into microsurgical procedures: Technical note. Neurosurgery 1998; 43: 392-395; discussion 395-396.
    • (1998) Neurosurgery , vol.43 , pp. 392-395
    • Levy, M.L.1    Chen, J.C.2    Moffitt, K.3    Corber, Z.4    McComb, J.G.5
  • 15
    • 34548822163 scopus 로고    scopus 로고
    • Craniotomy and clipping of intracranial aneurysm in a stereoscopic virtual reality environment
    • discussion 568-569.
    • Wong GK, Zhu CX, Ahuja AT, Poon WS,. Craniotomy and clipping of intracranial aneurysm in a stereoscopic virtual reality environment. Neurosurgery 2007; 61: 564-568; discussion 568-569.
    • (2007) Neurosurgery , vol.61 , pp. 564-568
    • Wong, G.K.1    Zhu, C.X.2    Ahuja, A.T.3    Poon, W.S.4
  • 16
    • 0027381480 scopus 로고
    • Three-dimensional Hi-vision system for microneurosurgical documentation based on wide-vision telepresence system using one camera and one monitor
    • Okudera H, Kobayashi S, Kyoshima K, Saito H, Mochizuki R,. Three-dimensional Hi-vision system for microneurosurgical documentation based on wide-vision telepresence system using one camera and one monitor. Neurol Med Chir (Tokyo) 1993; 33: 719-721.
    • (1993) Neurol Med Chir (Tokyo) , vol.33 , pp. 719-721
    • Okudera, H.1    Kobayashi, S.2    Kyoshima, K.3    Saito, H.4    Mochizuki, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.