Volumn 109, Issue 3, 2012, Pages 1291-1296

Isothermal versus non-isothermal calorimetric technique to evaluate thermokinetic parameters and thermal hazard of tert-butyl peroxy-2-ethyl hexanoate

Author keywords

Differential scanning calorimetry (DSC); Liquid organic peroxide; Liquid thermal explosion model; Thermal activity monitor III (TAM III); Thermokinetic parameters

Indexed keywords

CALORIMETRIC TECHNIQUES; HEXANOATE; ISOTHERMAL KINETICS; ISOTHERMAL TIME; LIQUID ORGANIC PEROXIDES; MAXIMUM TEMPERATURE; NON-ISOTHERMAL KINETIC; NONISOTHERMAL; ONSET TEMPERATURE; OPTIMAL CONDITIONS; PROCESS INDUSTRIES; RUNAWAY REACTION; SELF-ACCELERATING DECOMPOSITION TEMPERATURES; SIMULATION SOFTWARE; TAM III; THERMAL ACTIVITY MONITOR; THERMAL EXPLOSION; THERMAL HAZARDS; THERMOKINETIC PARAMETERS;

EID: 84867400701     PISSN: 13886150     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10973-012-2519-8     Document Type: Conference Paper
Times cited : (10)

References (24)
  • 1
    • 56149111589 scopus 로고    scopus 로고
    • Investigation of the decomposition reaction and dust explosion characteristics of crystalline benzoyl peroxides
    • Lu KT, Chen TC, Hu KH. Investigation of the decomposition reaction and dust explosion characteristics of crystalline benzoyl peroxides. J Hazard Mater. 2010;161:246-56.
    • (2010) J Hazard Mater , vol.161 , pp. 246-256
    • Lu, K.T.1    Chen, T.C.2    Hu, K.H.3
  • 3
    • 84867402249 scopus 로고    scopus 로고
    • United Nations, Committee of Experts on the Transport of Dangerous Goods, 14th Revised Ed., USA. 2005;205
    • United Nations, Committee of Experts on the Transport of Dangerous Goods, 14th Revised Ed., USA. 2005;205.
  • 4
    • 3042716987 scopus 로고
    • Determination of self-accelerating decomposition temperatures for self-reactive substances
    • Fisher HG, Goetz DD. Determination of self-accelerating decomposition temperatures for self-reactive substances. J Loss Prev Proc Ind. 1993;6:183-94.
    • (1993) J Loss Prev Proc Ind , vol.6 , pp. 183-194
    • Fisher, H.G.1    Goetz, D.D.2
  • 5
    • 84879405503 scopus 로고    scopus 로고
    • Gassy system vent sizing the role of two-phase flow
    • Burr Bidge, IL: Fauske and Associates, LLC
    • Fauske HK. Gassy system vent sizing the role of two-phase flow. Process Safety News. Burr Bidge, IL: Fauske and Associates, LLC; 2011;18:3.
    • (2011) Process Safety News , vol.18 , pp. 3
    • Fauske, H.K.1
  • 7
    • 0011380658 scopus 로고    scopus 로고
    • Akzo Nobel Chemicals bv Stationsplein, 4. P.O. Box 247, 3800 AE Amersfoort, The Netherlands
    • Material Safety Data Sheet. Akzo Nobel Chemicals bv Stationsplein, 4. P.O. Box 247, 3800 AE Amersfoort, The Netherlands; 2007.
    • (2007) Material Safety Data Sheet
  • 8
    • 46449132078 scopus 로고    scopus 로고
    • Thermal decomposition of hydrogen peroxide in the presence of sulfuric acid
    • Wu LK, Chen KY, Cheng SY, Lee BS, Shu CM. Thermal decomposition of hydrogen peroxide in the presence of sulfuric acid. J Therm Anal Calorim. 2008;93:115-20.
    • (2008) J Therm Anal Calorim , vol.93 , pp. 115-120
    • Wu, L.K.1    Chen, K.Y.2    Cheng, S.Y.3    Lee, B.S.4    Shu, C.M.5
  • 9
    • 33746443380 scopus 로고    scopus 로고
    • Reactive incompatibility of cumene hydroperoxide mixed with alkaline solutions
    • Hou HY, Duh YS, Lin WH, Shu CM. Reactive incompatibility of cumene hydroperoxide mixed with alkaline solutions. J Therm Anal Calorim. 2006;85:145-50.
    • (2006) J Therm Anal Calorim , vol.85 , pp. 145-150
    • Hou, H.Y.1    Duh, Y.S.2    Lin, W.H.3    Shu, C.M.4
  • 10
    • 44649151119 scopus 로고    scopus 로고
    • Hazard ratings for organic peroxides
    • Duh YS, Wu XH, Kao CS. Hazard ratings for organic peroxides. Process Saf Prog. 2008;27:89-99.
    • (2008) Process Saf Prog , vol.27 , pp. 89-99
    • Duh, Y.S.1    Wu, X.H.2    Kao, C.S.3
  • 12
    • 74849117553 scopus 로고    scopus 로고
    • Modeling solid thermal explosion containment on reactor HNIW and HMX
    • Lin CP, Chang CP, Chou YC, Shu CM. Modeling solid thermal explosion containment on reactor HNIW and HMX. J Hazard Mater. 2010;176:549-58.
    • (2010) J Hazard Mater , vol.176 , pp. 549-558
    • Lin, C.P.1    Chang, C.P.2    Chou, Y.C.3    Shu, C.M.4
  • 14
    • 84860303319 scopus 로고    scopus 로고
    • TAM III Thermostat
    • Product Information. 2012. TAM III Thermostat. www.thermo metric.com.
    • (2012) Product Information
  • 15
    • 77951253168 scopus 로고    scopus 로고
    • Comparisons of nthorder kinetic algorithms and kinetic model simulation on HMX by DSC tests
    • Lin CP, Chang YM, Tseng JM, Shu CM. Comparisons of nthorder kinetic algorithms and kinetic model simulation on HMX by DSC tests. J Therm Anal Calorim. 2010;100:607-14.
    • (2010) J Therm Anal Calorim , vol.100 , pp. 607-614
    • Lin, C.P.1    Chang, Y.M.2    Tseng, J.M.3    Shu, C.M.4
  • 16
    • 84867398558 scopus 로고    scopus 로고
    • Thermal Safety Software (TSS). St. Petersburg Russia
    • Thermal safety software (TSS). St. Petersburg, Russia: ChemInform Saint-Petersburg (CISP) Ltd. http://www.cisp.spb.ru.
  • 17
    • 79951512239 scopus 로고    scopus 로고
    • Further explanations of lauroyl peroxide runaway reaction by DSC tests and simulations
    • You ML, Shu CM. Further explanations of lauroyl peroxide runaway reaction by DSC tests and simulations. J Therm Anal Calorim. 2011;103:411-2.
    • (2011) J Therm Anal Calorim , vol.103 , pp. 411-412
    • You, M.L.1    Shu, C.M.2
  • 18
    • 84455202292 scopus 로고    scopus 로고
    • Green technology for improving process manufacturing design and storage management of organic peroxide
    • Lin CP, Tseng JM. Green technology for improving process manufacturing design and storage management of organic peroxide. Chem Eng J. 2012;180:284-92.
    • (2012) Chem Eng J , vol.180 , pp. 284-292
    • Lin, C.P.1    Tseng, J.M.2
  • 19
    • 68349100145 scopus 로고    scopus 로고
    • Thermal hazards evaluation of cumene hydroperoxide mixed with its derivatives
    • Peng JJ, Wu SH, Hou HY, Lin CP, Shu CM. Thermal hazards evaluation of cumene hydroperoxide mixed with its derivatives. J Therm Anal Calorim. 2009;96:783-7.
    • (2009) J Therm Anal Calorim , vol.96 , pp. 783-787
    • Peng, J.J.1    Wu, S.H.2    Hou, H.Y.3    Lin, C.P.4    Shu, C.M.5
  • 20
    • 80053324379 scopus 로고    scopus 로고
    • Thermokinetic parameters and thermal hazard evaluation for three organic peroxides by DSC and TAM III
    • Liu SH, Lin CP, Shu CM. Thermokinetic parameters and thermal hazard evaluation for three organic peroxides by DSC and TAM III. J Therm Anal Calorim. 2011;106:165-72.
    • (2011) J Therm Anal Calorim , vol.106 , pp. 165-172
    • Liu, S.H.1    Lin, C.P.2    Shu, C.M.3
  • 23
    • 16344386403 scopus 로고    scopus 로고
    • Prediction of the self-accelerating decomposition temperature (SADT) for liquid organic peroxides from differential scanning calorimetry (DSC) measurements
    • Malow M, Wehrstedt KD. Prediction of the self-accelerating decomposition temperature (SADT) for liquid organic peroxides from differential scanning calorimetry (DSC) measurements. J Hazard Mater. 2005;120:21-4.
    • (2005) J Hazard Mater , vol.120 , pp. 21-24
    • Malow, M.1    Wehrstedt, K.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.