메뉴 건너뛰기




Volumn 188, Issue 5, 2012, Pages 1855-1860

Infection retardant coated inflatable penile prostheses decrease the incidence of infection: A systematic review and meta-analysis

Author keywords

anti bacterial agents; infection; penile prosthesis; penis; postoperative complications

Indexed keywords

GENTAMICIN; MINOCYCLINE; RIFAMPICIN; VANCOMYCIN;

EID: 84867397612     PISSN: 00225347     EISSN: 15273792     Source Type: Journal    
DOI: 10.1016/j.juro.2012.07.022     Document Type: Article
Times cited : (101)

References (27)
  • 1
    • 0344752528 scopus 로고    scopus 로고
    • Evaluation and nonsurgical management of erectile dysfunction and priapism
    • 8th ed. P.C. Walsh, A.B. Retik, E.D. Vaughan Jr Saunders Philadelphia chap 46
    • G.A. Broderick, T.F. Lue Evaluation and nonsurgical management of erectile dysfunction and priapism 8th ed. P.C. Walsh, A.B. Retik, E.D. Vaughan Jr Campbell's Urology vol 2 2007 Saunders Philadelphia 1620 chap 46
    • (2007) Campbell's Urology , vol.2 , pp. 1620
    • Broderick, G.A.1    Lue, T.F.2
  • 4
    • 74049088979 scopus 로고    scopus 로고
    • Implants, mechanical devices, and vascular surgery for erectile dysfunction
    • W.J. Hellstrom, D.K. Montague, I. Moncada Implants, mechanical devices, and vascular surgery for erectile dysfunction J Sex Med 7 2010 501
    • (2010) J Sex Med , vol.7 , pp. 501
    • Hellstrom, W.J.1    Montague, D.K.2    Moncada, I.3
  • 5
    • 20144364892 scopus 로고    scopus 로고
    • The penile implant for erectile dysfunction
    • J.J. Mulcahy, E. Austoni, J.H. Barada The penile implant for erectile dysfunction J Sex Med 1 2004 98
    • (2004) J Sex Med , vol.1 , pp. 98
    • Mulcahy, J.J.1    Austoni, E.2    Barada, J.H.3
  • 6
    • 0015649828 scopus 로고
    • Management of erectile impotence Use of implantable inflatable prosthesis
    • S.F. Brantly, W.E. Bradley, G.W. Timm Management of erectile impotence Use of implantable inflatable prosthesis Urology 2 1973 80
    • (1973) Urology , vol.2 , pp. 80
    • Brantly, S.F.1    Bradley, W.E.2    Timm, G.W.3
  • 7
    • 77958082325 scopus 로고    scopus 로고
    • Penile prosthesis infection: Progress in prevention and treatment
    • J.J. Mulcahy Penile prosthesis infection: progress in prevention and treatment Curr Urol Rep 11 2010 400
    • (2010) Curr Urol Rep , vol.11 , pp. 400
    • Mulcahy, J.J.1
  • 8
    • 84855353247 scopus 로고    scopus 로고
    • Biofilm and penile prosthesis infections in the era of coated implants: A review
    • S.K. Wilson, J.W. Costerton Biofilm and penile prosthesis infections in the era of coated implants: a review J Sex Med 9 2012 44
    • (2012) J Sex Med , vol.9 , pp. 44
    • Wilson, S.K.1    Costerton, J.W.2
  • 9
    • 79955151433 scopus 로고    scopus 로고
    • Contemporary revision penile prosthesis surgery is not associated with a high risk of implant colonization or infection: A single-surgeon series
    • B.R. Kava, P. Kanagarajah, R. Ayyathurai Contemporary revision penile prosthesis surgery is not associated with a high risk of implant colonization or infection: a single-surgeon series J Sex Med 8 2011 1540
    • (2011) J Sex Med , vol.8 , pp. 1540
    • Kava, B.R.1    Kanagarajah, P.2    Ayyathurai, R.3
  • 10
    • 3142574629 scopus 로고    scopus 로고
    • What drives bacteria to produce a biofilm?
    • K.K. Jefferson What drives bacteria to produce a biofilm? FEMS Microbiol Lett 236 2004 163
    • (2004) FEMS Microbiol Lett , vol.236 , pp. 163
    • Jefferson, K.K.1
  • 11
    • 1642295714 scopus 로고    scopus 로고
    • Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants
    • C.C. Carson Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants J Urol 171 2004 1611
    • (2004) J Urol , vol.171 , pp. 1611
    • Carson, C.C.1
  • 12
    • 22144497123 scopus 로고    scopus 로고
    • Antibiotic coating reduces penile prosthesis infection
    • D. Droggin, R. Shabsigh, A.G. Anastasiadis Antibiotic coating reduces penile prosthesis infection J Sex Med 2 2005 565
    • (2005) J Sex Med , vol.2 , pp. 565
    • Droggin, D.1    Shabsigh, R.2    Anastasiadis, A.G.3
  • 14
    • 0032145398 scopus 로고    scopus 로고
    • Does surgical approach affect the incidence of inflatable penile prosthesis infection?
    • B.B. Garber, S.M. Marcus Does surgical approach affect the incidence of inflatable penile prosthesis infection? Urology 52 1998 291
    • (1998) Urology , vol.52 , pp. 291
    • Garber, B.B.1    Marcus, S.M.2
  • 15
    • 0030215864 scopus 로고    scopus 로고
    • Risk factors for penile prosthetic infection
    • J.P. Jarow Risk factors for penile prosthetic infection J Urol 156 1996 402
    • (1996) J Urol , vol.156 , pp. 402
    • Jarow, J.P.1
  • 16
    • 0023181129 scopus 로고
    • Periprosthetic infections
    • D.K. Montague Periprosthetic infections J Urol 138 1987 68
    • (1987) J Urol , vol.138 , pp. 68
    • Montague, D.K.1
  • 18
    • 0026501917 scopus 로고
    • Risk factors associated with penile prosthesis infections
    • S.B. Radomski, S. Herschorn Risk factors associated with penile prosthesis infections J Urol 147 1992 383
    • (1992) J Urol , vol.147 , pp. 383
    • Radomski, S.B.1    Herschorn, S.2
  • 19
    • 0028877515 scopus 로고
    • Inflatable penile implant infection: Predisposing factors and treatment suggestions
    • S.K. Wilson, J.R. Delk Inflatable penile implant infection: predisposing factors and treatment suggestions J Urol 153 1995 659
    • (1995) J Urol , vol.153 , pp. 659
    • Wilson, S.K.1    Delk, J.R.2
  • 20
    • 0032459836 scopus 로고    scopus 로고
    • Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin
    • S.K. Wilson, C.C. Carson, M.A. Cleves Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin J Urol 159 1998 1537
    • (1998) J Urol , vol.159 , pp. 1537
    • Wilson, S.K.1    Carson, C.C.2    Cleves, M.A.3
  • 21
    • 15844379523 scopus 로고    scopus 로고
    • The hydrophilic-coated inflatable penile prosthesis: 1-year experience
    • C.E. Wolter, W.J. Hellstrom The hydrophilic-coated inflatable penile prosthesis: 1-year experience J Sex Med 1 2004 221
    • (2004) J Sex Med , vol.1 , pp. 221
    • Wolter, C.E.1    Hellstrom, W.J.2
  • 22
    • 33750507676 scopus 로고    scopus 로고
    • Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure
    • R. Abouassaly, K.W. Angermeier, D.K. Montague Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure J Urol 176 2006 2471
    • (2006) J Urol , vol.176 , pp. 2471
    • Abouassaly, R.1    Angermeier, K.W.2    Montague, D.K.3
  • 23
    • 78650766149 scopus 로고    scopus 로고
    • Infection rates of rifampin/gentamicin-coated Titan Coloplast penile implants Comparison with Inhibizone-impregnated AMS penile implants
    • C. Dhabuwala, S. Sheth, B. Zamzow Infection rates of rifampin/gentamicin- coated Titan Coloplast penile implants Comparison with Inhibizone-impregnated AMS penile implants J Sex Med 8 2011 315
    • (2011) J Sex Med , vol.8 , pp. 315
    • Dhabuwala, C.1    Sheth, S.2    Zamzow, B.3
  • 24
    • 78650776912 scopus 로고    scopus 로고
    • Coloplast titan inflatable penile prosthesis with one-touch release pump: Review of 100 cases and comparison with genesis pump
    • T. Shaw, B.B. Garber Coloplast titan inflatable penile prosthesis with one-touch release pump: review of 100 cases and comparison with genesis pump J Sex Med 8 2011 310
    • (2011) J Sex Med , vol.8 , pp. 310
    • Shaw, T.1    Garber, B.B.2
  • 25
    • 34548458196 scopus 로고    scopus 로고
    • Infection reduction using antibiotic-coated inflatable penile prosthesis
    • S.K. Wilson, J. Zumbe, G.D. Henry Infection reduction using antibiotic-coated inflatable penile prosthesis Urology 70 2007 337
    • (2007) Urology , vol.70 , pp. 337
    • Wilson, S.K.1    Zumbe, J.2    Henry, G.D.3
  • 26
    • 78651266469 scopus 로고    scopus 로고
    • Long-term infection outcomes after original antibiotic impregnated inflatable penile prosthesis implants: Up to 7.7 years of followup
    • C.C. Carson 3rd, J.J. Mulcahy, M.R. Harsch Long-term infection outcomes after original antibiotic impregnated inflatable penile prosthesis implants: up to 7.7 years of followup J Urol 185 2011 614
    • (2011) J Urol , vol.185 , pp. 614
    • Carson III, C.C.1    Mulcahy, J.J.2    Harsch, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.