-
2
-
-
0032514733
-
Risk to Patients From Radiation Associated With Radiofrequency Ablation for Supraventricular Tachycardia
-
10.1161/01.CIR.98.15.1534
-
Kovoor P. Ricciardello M. Collins L. Uther J. Ross D. Risk to Patients From Radiation Associated With Radiofrequency Ablation for Supraventricular Tachycardia. Circulation 1998, 98:1534-1540. 10.1161/01.CIR.98.15.1534
-
(1998)
Circulation
, vol.98
, pp. 1534-1540
-
-
Kovoor, P.1
Ricciardello, M.2
Collins, L.3
Uther, J.4
Ross, D.5
-
3
-
-
0022615422
-
Radiation Doses and Somatic Risk to Patients During Cardiac Radiological Procedures
-
10.1259/0007-1285-59-700-359, and
-
Faulkner K. Love H.G. Sweeney J.K. Bardsley R.A. Radiation Doses and Somatic Risk to Patients During Cardiac Radiological Procedures. Br. J. Radiol. 59:359-363. 10.1259/0007-1285-59-700-359
-
Br. J. Radiol.
, vol.59
, pp. 359-363
-
-
Faulkner, K.1
Love, H.G.2
Sweeney, J.K.3
Bardsley, R.A.4
-
4
-
-
10744224950
-
Cardiac Catheterisation Guided by MRI in Children and Adults With Congenital Heart Disease
-
10.1016/S0140-6736(03)14956-2
-
Razavi R. Hill D.L. Keevil S.F. Miquel M.E. Muthurangu V. Hegde S. Rhode K. Barnett M. Vaals J.V. Hawkes D.J. Baker E. Cardiac Catheterisation Guided by MRI in Children and Adults With Congenital Heart Disease. Lancet 2003, 362:1877-1882. 10.1016/S0140-6736(03)14956-2
-
(2003)
Lancet
, vol.362
, pp. 1877-1882
-
-
Razavi, R.1
Hill, D.L.2
Keevil, S.F.3
Miquel, M.E.4
Muthurangu, V.5
Hegde, S.6
Rhode, K.7
Barnett, M.8
Vaals, J.V.9
Hawkes, D.J.10
Baker, E.11
-
5
-
-
38949146659
-
MR-Guided Intravascular Interventions: Techniques and Applications
-
10.1002/jmri.21271
-
Bock M. Wacker F.K. MR-Guided Intravascular Interventions: Techniques and Applications. J. Magn. Reson. Imaging 2008, 27(2):326-338. 10.1002/jmri.21271
-
(2008)
J. Magn. Reson. Imaging
, vol.27
, Issue.2
, pp. 326-338
-
-
Bock, M.1
Wacker, F.K.2
-
6
-
-
23044463590
-
The Value of Magnetic Resonance Guided Cardiac Catheterisation
-
10.1136/hrt.2004.055137
-
Muthurangu V. Razavi R.S. The Value of Magnetic Resonance Guided Cardiac Catheterisation. Heart 2005, 91:995-996. 10.1136/hrt.2004.055137
-
(2005)
Heart
, vol.91
, pp. 995-996
-
-
Muthurangu, V.1
Razavi, R.S.2
-
7
-
-
34447649202
-
Interventional Cardiovascular Magnetic Resonance Imaging
-
10.1016/j.tcm.2007.05.003
-
Raman V.K. Lederman R.J. Interventional Cardiovascular Magnetic Resonance Imaging. Trends Cardiovasc. Med. 2007, 17(6):196-202. 10.1016/j.tcm.2007.05.003
-
(2007)
Trends Cardiovasc. Med.
, vol.17
, Issue.6
, pp. 196-202
-
-
Raman, V.K.1
Lederman, R.J.2
-
8
-
-
0025674137
-
Magnetic Susceptibility Effects and Their Application in the Development of New Ferromagnetic Catheters for Magnetic Resonance Imaging
-
10.1097/00004424-199012000-00010
-
Rubin D.L. Ratner A.V. Young S.W. Magnetic Susceptibility Effects and Their Application in the Development of New Ferromagnetic Catheters for Magnetic Resonance Imaging. Invest. Radiol. 1990, 25(12):1325-1332. 10.1097/00004424-199012000-00010
-
(1990)
Invest. Radiol.
, vol.25
, Issue.12
, pp. 1325-1332
-
-
Rubin, D.L.1
Ratner, A.V.2
Young, S.W.3
-
9
-
-
33645814205
-
MRI/fMRI-Compatible Robotic System With Force Feedback for Interaction With Human Motion
-
10.1109/TMECH.2006.871897
-
Gassert R. Moser R. Burdet E. Bleuler H. MRI/fMRI-Compatible Robotic System With Force Feedback for Interaction With Human Motion. IEEE/ASME Trans. Mechatron. 2006, 11(2):216-224. 10.1109/TMECH.2006.871897
-
(2006)
IEEE/ASME Trans. Mechatron.
, vol.11
, Issue.2
, pp. 216-224
-
-
Gassert, R.1
Moser, R.2
Burdet, E.3
Bleuler, H.4
-
10
-
-
0031662758
-
MR-Guided Percutaneous Angioplasty: Assessment of Tracking Safety, Catheter Handling and Functionality
-
10.1007/s002709900288
-
Wildermuth S. Dumoulin C.L. Pfammatter T. Maier S.E. Hofmann E. Debatin J.F. MR-Guided Percutaneous Angioplasty: Assessment of Tracking Safety, Catheter Handling and Functionality. Cardiovasc. Intervent. Radiol. 1998, 21:404-410. 10.1007/s002709900288
-
(1998)
Cardiovasc. Intervent. Radiol.
, vol.21
, pp. 404-410
-
-
Wildermuth, S.1
Dumoulin, C.L.2
Pfammatter, T.3
Maier, S.E.4
Hofmann, E.5
Debatin, J.F.6
-
11
-
-
0033945858
-
Heating Around Intravascular Guidewires by Resonating RF Waves
-
10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T
-
Konings M.K. Bartels L.W. Smits H.F. M. Bakker C.J. G. Heating Around Intravascular Guidewires by Resonating RF Waves. J. Magn. Reson. Imaging 2000, 12:79-85. 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T
-
(2000)
J. Magn. Reson. Imaging
, vol.12
, pp. 79-85
-
-
Konings, M.K.1
Bartels, L.W.2
Smits, H.F.M.3
Bakker, C.J.G.4
-
12
-
-
0035172358
-
On the Heating of Linear Conductive Structures as Guidewires and Catheters in Interventional MRI
-
10.1002/1522-2586(200101)13:1<105::AID-JMRI1016>3.0.CO;2-0
-
Nitz W.G. Oppelt A. Renz W. Manke C. Lenhart M. Link J. On the Heating of Linear Conductive Structures as Guidewires and Catheters in Interventional MRI. J. Magn. Reson. Imaging 2001, 13:105-114. 10.1002/1522-2586(200101)13:1<105::AID-JMRI1016>3.0.CO;2-0
-
(2001)
J. Magn. Reson. Imaging
, vol.13
, pp. 105-114
-
-
Nitz, W.G.1
Oppelt, A.2
Renz, W.3
Manke, C.4
Lenhart, M.5
Link, J.6
-
14
-
-
0030013529
-
The Role of Magnetic Susceptibility in Magnetic Resonance Imaging: MRI Magnetic Compatibility of the First and Second Kinds
-
10.1118/1.597854
-
Schench J.F. The Role of Magnetic Susceptibility in Magnetic Resonance Imaging: MRI Magnetic Compatibility of the First and Second Kinds. Med. Phys. 1996, 23(6):815-851. 10.1118/1.597854
-
(1996)
Med. Phys.
, vol.23
, Issue.6
, pp. 815-851
-
-
Schench, J.F.1
-
15
-
-
3042781261
-
Engineering Considerations of Catheters for Intravascular Ultrasonic Measurements
-
Martin R.W. Johnson C.C. Engineering Considerations of Catheters for Intravascular Ultrasonic Measurements. Proc. SPIE 1989, 1068:198-206. and "," pp.
-
(1989)
Proc. SPIE
, vol.1068
, pp. 198-206
-
-
Martin, R.W.1
Johnson, C.C.2
-
16
-
-
3042762904
-
Design of Braided Composite Cardiovascular Catheters Based on Required Axial, Flexural, and Torsional Rigidities
-
10.1002/jbm.b.30017
-
Carey J. Fahim A. Munro M. Design of Braided Composite Cardiovascular Catheters Based on Required Axial, Flexural, and Torsional Rigidities. J. Biomed. Mater. Res., Part B: Appl. Biomater. 2004, 70(1):73-78. 10.1002/jbm.b.30017
-
(2004)
J. Biomed. Mater. Res., Part B: Appl. Biomater.
, vol.70
, Issue.1
, pp. 73-78
-
-
Carey, J.1
Fahim, A.2
Munro, M.3
-
17
-
-
33748991754
-
Nitinol: Shape-Memory and Super-Elastic Materials in Surgery
-
10.1007/s00464-005-0867-1
-
Szold A. Nitinol: Shape-Memory and Super-Elastic Materials in Surgery. Surg. Endosc. 2006, 20:1493-1496. 10.1007/s00464-005-0867-1
-
(2006)
Surg. Endosc.
, vol.20
, pp. 1493-1496
-
-
Szold, A.1
-
18
-
-
0039171080
-
An Overview of Nitinol Medical Applications
-
10.1016/S0921-5093(99)00294-4
-
Duerig T. Pelton A. Stockel D. An Overview of Nitinol Medical Applications. Mater. Sci. Eng. 1999, A273-275:149-160. 10.1016/S0921-5093(99)00294-4
-
(1999)
Mater. Sci. Eng.
, vol.A273-275
, pp. 149-160
-
-
Duerig, T.1
Pelton, A.2
Stockel, D.3
-
19
-
-
77950886554
-
Whole Shaft Visibility and Mechanical Performance for Active MR Catheters Using Copper-Nitinol Braided Polymer Tubes
-
10.1186/1532-429X-11-29
-
Kocaturk O. Saikusl C.E. Guttman M.A. Faranesh A.Z. Ratnayaka K. Ozturk C. McVeigh E.R. Lederman R.J. Whole Shaft Visibility and Mechanical Performance for Active MR Catheters Using Copper-Nitinol Braided Polymer Tubes. J. Cardiovasc. Magn. Reson. 2009, 11(29):11-29. 10.1186/1532-429X-11-29
-
(2009)
J. Cardiovasc. Magn. Reson.
, vol.11
, Issue.29
, pp. 11-29
-
-
Kocaturk, O.1
Saikusl, C.E.2
Guttman, M.A.3
Faranesh, A.Z.4
Ratnayaka, K.5
Ozturk, C.6
McVeigh, E.R.7
Lederman, R.J.8
-
20
-
-
84867295261
-
MRI Ablation Catheter
-
"," U.S. Patent No. US0208252.
-
O'Boyle G.S. Gibson III C.A. MRI Ablation Catheter. 2003, and "," U.S. Patent No. US0208252.
-
(2003)
-
-
O'Boyle, G.S.1
Gibson III, C.A.2
-
21
-
-
84867287083
-
Imricor Medical Systems
-
Imricor
-
Imricor Medical Systems. 2011, Imricor, ",".
-
(2011)
-
-
-
22
-
-
30344441834
-
Buckling Test as a New Approach to Testing Flexural Rigidities of Angiographic Catheters
-
10.1002/jbm.b.30358
-
Carey J. Emery D. McCracken P. Buckling Test as a New Approach to Testing Flexural Rigidities of Angiographic Catheters. J. Biomed. Mater. Res., Part B: Appl. Biomater. 2006, 76(1):211-218. 10.1002/jbm.b.30358
-
(2006)
J. Biomed. Mater. Res., Part B: Appl. Biomater.
, vol.76
, Issue.1
, pp. 211-218
-
-
Carey, J.1
Emery, D.2
McCracken, P.3
-
23
-
-
0031900145
-
Torsion Measurement of Catheters Using Polarized Light in a Single Glass Fibre
-
10.1088/0031-9155/43/5/001
-
Koningsyz M.K. van Leeuwenx T.G. Maliy W.P. Viergevery M.A. Torsion Measurement of Catheters Using Polarized Light in a Single Glass Fibre. Phys. Med. Biol. 1998, 43:1049-1057. 10.1088/0031-9155/43/5/001
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 1049-1057
-
-
Koningsyz, M.K.1
van Leeuwenx, T.G.2
Maliy, W.P.3
Viergevery, M.A.4
-
24
-
-
0033624245
-
Torquability of Microcatheter Guidewires: The Resulting Torsional Moment
-
Ceschinski H. Henkes H. Weinert H. Weber W. Kühne D. Monstadt H. Torquability of Microcatheter Guidewires: The Resulting Torsional Moment. Biomed. Mater. Eng. 2000, 10(1):31-42. and "," pp.
-
(2000)
Biomed. Mater. Eng.
, vol.10
, Issue.1
, pp. 31-42
-
-
Ceschinski, H.1
Henkes, H.2
Weinert, H.3
Weber, W.4
Kühne, D.5
Monstadt, H.6
-
25
-
-
65549170557
-
A Comparison of the Mechanical Performance Characteristics of Seven Drug-Eluting Stent Systems
-
10.1002/ccd.21832
-
Schmidt W. Lanzer P. Behrens P. Topoleski L.D. Schmitz K.P. A Comparison of the Mechanical Performance Characteristics of Seven Drug-Eluting Stent Systems. Cathet. Cardiovasc. Intervent. 2009, 73:350-360. 10.1002/ccd.21832
-
(2009)
Cathet. Cardiovasc. Intervent.
, vol.73
, pp. 350-360
-
-
Schmidt, W.1
Lanzer, P.2
Behrens, P.3
Topoleski, L.D.4
Schmitz, K.P.5
-
26
-
-
31944448891
-
A Polymer-Based MR-Compatible Guidewire: A Study to Explore New Prospects for Interventional Peripheral Magnetic Resonance Angiography (ipMRA)
-
10.1002/jmri.20486
-
Mekle R. Hofmann E. Scheffler K. Bilecen D. A Polymer-Based MR-Compatible Guidewire: A Study to Explore New Prospects for Interventional Peripheral Magnetic Resonance Angiography (ipMRA). J. Magn. Reson. Imaging 2006, 23:145-155. 10.1002/jmri.20486
-
(2006)
J. Magn. Reson. Imaging
, vol.23
, pp. 145-155
-
-
Mekle, R.1
Hofmann, E.2
Scheffler, K.3
Bilecen, D.4
-
27
-
-
0029051232
-
Case Report: A New Guidewire for Coronary Ablation
-
10.1002/ccd.1810350112
-
Brown R.I. Penn I.M. Viera F.M. Case Report: A New Guidewire for Coronary Ablation. Cathet. Cardiovasc. Diagn. 1995, 35(1):59-63. 10.1002/ccd.1810350112
-
(1995)
Cathet. Cardiovasc. Diagn.
, vol.35
, Issue.1
, pp. 59-63
-
-
Brown, R.I.1
Penn, I.M.2
Viera, F.M.3
-
28
-
-
79952129825
-
MRI-Compatible Intensity-Modulated Force Sensor for Cardiac Catheterization Procedures
-
10.1109/TBME.2010.2095853
-
Polygerinos P. Ataollahi A. Schaeffter T. Razavi R. Seneviratne L.D. Althoefer K. MRI-Compatible Intensity-Modulated Force Sensor for Cardiac Catheterization Procedures. IEEE Trans. Biomed. Eng. 2001, 58(3):721-726. 10.1109/TBME.2010.2095853
-
(2001)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.3
, pp. 721-726
-
-
Polygerinos, P.1
Ataollahi, A.2
Schaeffter, T.3
Razavi, R.4
Seneviratne, L.D.5
Althoefer, K.6
-
29
-
-
0038300481
-
Procedural Complications Following Diagnostic Coronary Angiography are Related to the Operator's Experience and the Catheter Size
-
10.1002/ccd.10489
-
Ammann P. Rocca H.P. Angehrn W. Roelli H. Sagmeister M. Rickli H. Procedural Complications Following Diagnostic Coronary Angiography are Related to the Operator's Experience and the Catheter Size. Cathet. Cardiovasc. Intervent. 2003, 59:13-18. 10.1002/ccd.10489
-
(2003)
Cathet. Cardiovasc. Intervent.
, vol.59
, pp. 13-18
-
-
Ammann, P.1
Rocca, H.P.2
Angehrn, W.3
Roelli, H.4
Sagmeister, M.5
Rickli, H.6
|