메뉴 건너뛰기




Volumn 6, Issue 4, 2012, Pages

Developing a Magnetic Resonance-Compatible Catheter for Cardiac Catheterization

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC CATHETERIZATIONS; CARDIAC INTERVENTIONS; EXPERIMENTAL STUDIES; MECHANICAL PERFORMANCE; MR-COMPATIBILITY; MR-COMPATIBLE; MRI SCANNERS; SOFT TISSUE;

EID: 84867320568     PISSN: 19326181     EISSN: 1932619X     Source Type: Journal    
DOI: 10.1115/1.4007281     Document Type: Article
Times cited : (7)

References (30)
  • 2
    • 0032514733 scopus 로고    scopus 로고
    • Risk to Patients From Radiation Associated With Radiofrequency Ablation for Supraventricular Tachycardia
    • 10.1161/01.CIR.98.15.1534
    • Kovoor P. Ricciardello M. Collins L. Uther J. Ross D. Risk to Patients From Radiation Associated With Radiofrequency Ablation for Supraventricular Tachycardia. Circulation 1998, 98:1534-1540. 10.1161/01.CIR.98.15.1534
    • (1998) Circulation , vol.98 , pp. 1534-1540
    • Kovoor, P.1    Ricciardello, M.2    Collins, L.3    Uther, J.4    Ross, D.5
  • 3
    • 0022615422 scopus 로고    scopus 로고
    • Radiation Doses and Somatic Risk to Patients During Cardiac Radiological Procedures
    • 10.1259/0007-1285-59-700-359, and
    • Faulkner K. Love H.G. Sweeney J.K. Bardsley R.A. Radiation Doses and Somatic Risk to Patients During Cardiac Radiological Procedures. Br. J. Radiol. 59:359-363. 10.1259/0007-1285-59-700-359
    • Br. J. Radiol. , vol.59 , pp. 359-363
    • Faulkner, K.1    Love, H.G.2    Sweeney, J.K.3    Bardsley, R.A.4
  • 5
    • 38949146659 scopus 로고    scopus 로고
    • MR-Guided Intravascular Interventions: Techniques and Applications
    • 10.1002/jmri.21271
    • Bock M. Wacker F.K. MR-Guided Intravascular Interventions: Techniques and Applications. J. Magn. Reson. Imaging 2008, 27(2):326-338. 10.1002/jmri.21271
    • (2008) J. Magn. Reson. Imaging , vol.27 , Issue.2 , pp. 326-338
    • Bock, M.1    Wacker, F.K.2
  • 6
    • 23044463590 scopus 로고    scopus 로고
    • The Value of Magnetic Resonance Guided Cardiac Catheterisation
    • 10.1136/hrt.2004.055137
    • Muthurangu V. Razavi R.S. The Value of Magnetic Resonance Guided Cardiac Catheterisation. Heart 2005, 91:995-996. 10.1136/hrt.2004.055137
    • (2005) Heart , vol.91 , pp. 995-996
    • Muthurangu, V.1    Razavi, R.S.2
  • 7
    • 34447649202 scopus 로고    scopus 로고
    • Interventional Cardiovascular Magnetic Resonance Imaging
    • 10.1016/j.tcm.2007.05.003
    • Raman V.K. Lederman R.J. Interventional Cardiovascular Magnetic Resonance Imaging. Trends Cardiovasc. Med. 2007, 17(6):196-202. 10.1016/j.tcm.2007.05.003
    • (2007) Trends Cardiovasc. Med. , vol.17 , Issue.6 , pp. 196-202
    • Raman, V.K.1    Lederman, R.J.2
  • 8
    • 0025674137 scopus 로고
    • Magnetic Susceptibility Effects and Their Application in the Development of New Ferromagnetic Catheters for Magnetic Resonance Imaging
    • 10.1097/00004424-199012000-00010
    • Rubin D.L. Ratner A.V. Young S.W. Magnetic Susceptibility Effects and Their Application in the Development of New Ferromagnetic Catheters for Magnetic Resonance Imaging. Invest. Radiol. 1990, 25(12):1325-1332. 10.1097/00004424-199012000-00010
    • (1990) Invest. Radiol. , vol.25 , Issue.12 , pp. 1325-1332
    • Rubin, D.L.1    Ratner, A.V.2    Young, S.W.3
  • 9
    • 33645814205 scopus 로고    scopus 로고
    • MRI/fMRI-Compatible Robotic System With Force Feedback for Interaction With Human Motion
    • 10.1109/TMECH.2006.871897
    • Gassert R. Moser R. Burdet E. Bleuler H. MRI/fMRI-Compatible Robotic System With Force Feedback for Interaction With Human Motion. IEEE/ASME Trans. Mechatron. 2006, 11(2):216-224. 10.1109/TMECH.2006.871897
    • (2006) IEEE/ASME Trans. Mechatron. , vol.11 , Issue.2 , pp. 216-224
    • Gassert, R.1    Moser, R.2    Burdet, E.3    Bleuler, H.4
  • 11
    • 0033945858 scopus 로고    scopus 로고
    • Heating Around Intravascular Guidewires by Resonating RF Waves
    • 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T
    • Konings M.K. Bartels L.W. Smits H.F. M. Bakker C.J. G. Heating Around Intravascular Guidewires by Resonating RF Waves. J. Magn. Reson. Imaging 2000, 12:79-85. 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T
    • (2000) J. Magn. Reson. Imaging , vol.12 , pp. 79-85
    • Konings, M.K.1    Bartels, L.W.2    Smits, H.F.M.3    Bakker, C.J.G.4
  • 12
    • 0035172358 scopus 로고    scopus 로고
    • On the Heating of Linear Conductive Structures as Guidewires and Catheters in Interventional MRI
    • 10.1002/1522-2586(200101)13:1<105::AID-JMRI1016>3.0.CO;2-0
    • Nitz W.G. Oppelt A. Renz W. Manke C. Lenhart M. Link J. On the Heating of Linear Conductive Structures as Guidewires and Catheters in Interventional MRI. J. Magn. Reson. Imaging 2001, 13:105-114. 10.1002/1522-2586(200101)13:1<105::AID-JMRI1016>3.0.CO;2-0
    • (2001) J. Magn. Reson. Imaging , vol.13 , pp. 105-114
    • Nitz, W.G.1    Oppelt, A.2    Renz, W.3    Manke, C.4    Lenhart, M.5    Link, J.6
  • 13
    • 60349093748 scopus 로고    scopus 로고
    • MR Imaging During Endovascular Procedures: An Evaluation of the Potential for Catheter Heating
    • 10.1002/mrm.21817
    • Martin A.J. Baek B. Acevedo-Bolton G. Higashida R. Comstock T.J. Saloner D.A. MR Imaging During Endovascular Procedures: An Evaluation of the Potential for Catheter Heating. Magn. Reson. Med. 2009, 61:45-53. 10.1002/mrm.21817
    • (2009) Magn. Reson. Med. , vol.61 , pp. 45-53
    • Martin, A.J.1    Baek, B.2    Acevedo-Bolton, G.3    Higashida, R.4    Comstock, T.J.5    Saloner, D.A.6
  • 14
    • 0030013529 scopus 로고    scopus 로고
    • The Role of Magnetic Susceptibility in Magnetic Resonance Imaging: MRI Magnetic Compatibility of the First and Second Kinds
    • 10.1118/1.597854
    • Schench J.F. The Role of Magnetic Susceptibility in Magnetic Resonance Imaging: MRI Magnetic Compatibility of the First and Second Kinds. Med. Phys. 1996, 23(6):815-851. 10.1118/1.597854
    • (1996) Med. Phys. , vol.23 , Issue.6 , pp. 815-851
    • Schench, J.F.1
  • 15
    • 3042781261 scopus 로고
    • Engineering Considerations of Catheters for Intravascular Ultrasonic Measurements
    • Martin R.W. Johnson C.C. Engineering Considerations of Catheters for Intravascular Ultrasonic Measurements. Proc. SPIE 1989, 1068:198-206. and "," pp.
    • (1989) Proc. SPIE , vol.1068 , pp. 198-206
    • Martin, R.W.1    Johnson, C.C.2
  • 16
    • 3042762904 scopus 로고    scopus 로고
    • Design of Braided Composite Cardiovascular Catheters Based on Required Axial, Flexural, and Torsional Rigidities
    • 10.1002/jbm.b.30017
    • Carey J. Fahim A. Munro M. Design of Braided Composite Cardiovascular Catheters Based on Required Axial, Flexural, and Torsional Rigidities. J. Biomed. Mater. Res., Part B: Appl. Biomater. 2004, 70(1):73-78. 10.1002/jbm.b.30017
    • (2004) J. Biomed. Mater. Res., Part B: Appl. Biomater. , vol.70 , Issue.1 , pp. 73-78
    • Carey, J.1    Fahim, A.2    Munro, M.3
  • 17
    • 33748991754 scopus 로고    scopus 로고
    • Nitinol: Shape-Memory and Super-Elastic Materials in Surgery
    • 10.1007/s00464-005-0867-1
    • Szold A. Nitinol: Shape-Memory and Super-Elastic Materials in Surgery. Surg. Endosc. 2006, 20:1493-1496. 10.1007/s00464-005-0867-1
    • (2006) Surg. Endosc. , vol.20 , pp. 1493-1496
    • Szold, A.1
  • 18
    • 0039171080 scopus 로고    scopus 로고
    • An Overview of Nitinol Medical Applications
    • 10.1016/S0921-5093(99)00294-4
    • Duerig T. Pelton A. Stockel D. An Overview of Nitinol Medical Applications. Mater. Sci. Eng. 1999, A273-275:149-160. 10.1016/S0921-5093(99)00294-4
    • (1999) Mater. Sci. Eng. , vol.A273-275 , pp. 149-160
    • Duerig, T.1    Pelton, A.2    Stockel, D.3
  • 20
    • 84867295261 scopus 로고    scopus 로고
    • MRI Ablation Catheter
    • "," U.S. Patent No. US0208252.
    • O'Boyle G.S. Gibson III C.A. MRI Ablation Catheter. 2003, and "," U.S. Patent No. US0208252.
    • (2003)
    • O'Boyle, G.S.1    Gibson III, C.A.2
  • 21
    • 84867287083 scopus 로고    scopus 로고
    • Imricor Medical Systems
    • Imricor
    • Imricor Medical Systems. 2011, Imricor, ",".
    • (2011)
  • 22
    • 30344441834 scopus 로고    scopus 로고
    • Buckling Test as a New Approach to Testing Flexural Rigidities of Angiographic Catheters
    • 10.1002/jbm.b.30358
    • Carey J. Emery D. McCracken P. Buckling Test as a New Approach to Testing Flexural Rigidities of Angiographic Catheters. J. Biomed. Mater. Res., Part B: Appl. Biomater. 2006, 76(1):211-218. 10.1002/jbm.b.30358
    • (2006) J. Biomed. Mater. Res., Part B: Appl. Biomater. , vol.76 , Issue.1 , pp. 211-218
    • Carey, J.1    Emery, D.2    McCracken, P.3
  • 23
    • 0031900145 scopus 로고    scopus 로고
    • Torsion Measurement of Catheters Using Polarized Light in a Single Glass Fibre
    • 10.1088/0031-9155/43/5/001
    • Koningsyz M.K. van Leeuwenx T.G. Maliy W.P. Viergevery M.A. Torsion Measurement of Catheters Using Polarized Light in a Single Glass Fibre. Phys. Med. Biol. 1998, 43:1049-1057. 10.1088/0031-9155/43/5/001
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1049-1057
    • Koningsyz, M.K.1    van Leeuwenx, T.G.2    Maliy, W.P.3    Viergevery, M.A.4
  • 25
    • 65549170557 scopus 로고    scopus 로고
    • A Comparison of the Mechanical Performance Characteristics of Seven Drug-Eluting Stent Systems
    • 10.1002/ccd.21832
    • Schmidt W. Lanzer P. Behrens P. Topoleski L.D. Schmitz K.P. A Comparison of the Mechanical Performance Characteristics of Seven Drug-Eluting Stent Systems. Cathet. Cardiovasc. Intervent. 2009, 73:350-360. 10.1002/ccd.21832
    • (2009) Cathet. Cardiovasc. Intervent. , vol.73 , pp. 350-360
    • Schmidt, W.1    Lanzer, P.2    Behrens, P.3    Topoleski, L.D.4    Schmitz, K.P.5
  • 26
    • 31944448891 scopus 로고    scopus 로고
    • A Polymer-Based MR-Compatible Guidewire: A Study to Explore New Prospects for Interventional Peripheral Magnetic Resonance Angiography (ipMRA)
    • 10.1002/jmri.20486
    • Mekle R. Hofmann E. Scheffler K. Bilecen D. A Polymer-Based MR-Compatible Guidewire: A Study to Explore New Prospects for Interventional Peripheral Magnetic Resonance Angiography (ipMRA). J. Magn. Reson. Imaging 2006, 23:145-155. 10.1002/jmri.20486
    • (2006) J. Magn. Reson. Imaging , vol.23 , pp. 145-155
    • Mekle, R.1    Hofmann, E.2    Scheffler, K.3    Bilecen, D.4
  • 27
    • 0029051232 scopus 로고
    • Case Report: A New Guidewire for Coronary Ablation
    • 10.1002/ccd.1810350112
    • Brown R.I. Penn I.M. Viera F.M. Case Report: A New Guidewire for Coronary Ablation. Cathet. Cardiovasc. Diagn. 1995, 35(1):59-63. 10.1002/ccd.1810350112
    • (1995) Cathet. Cardiovasc. Diagn. , vol.35 , Issue.1 , pp. 59-63
    • Brown, R.I.1    Penn, I.M.2    Viera, F.M.3
  • 29
    • 0038300481 scopus 로고    scopus 로고
    • Procedural Complications Following Diagnostic Coronary Angiography are Related to the Operator's Experience and the Catheter Size
    • 10.1002/ccd.10489
    • Ammann P. Rocca H.P. Angehrn W. Roelli H. Sagmeister M. Rickli H. Procedural Complications Following Diagnostic Coronary Angiography are Related to the Operator's Experience and the Catheter Size. Cathet. Cardiovasc. Intervent. 2003, 59:13-18. 10.1002/ccd.10489
    • (2003) Cathet. Cardiovasc. Intervent. , vol.59 , pp. 13-18
    • Ammann, P.1    Rocca, H.P.2    Angehrn, W.3    Roelli, H.4    Sagmeister, M.5    Rickli, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.