-
1
-
-
0032850414
-
National Survey of the incidence of Cervical Spine Injury and Approach to Cervical Spine Clearance in US trauma centre
-
G rossman MD, Reilly PM, Gillet T. National Survey of the incidence of Cervical Spine Injury and Approach to Cervical Spine Clearance in US trauma centre. J Trauma 1997;47:684-90.
-
(1997)
J Trauma
, vol.47
, pp. 684-690
-
-
Rossman, M.D.G.1
Reilly, P.M.2
Gillet, T.3
-
2
-
-
0027414239
-
Neurologic deterioration associated with airway management in a cervical spine injured patient
-
Hastings RH, Kelly SD. Neurologic deterioration associated with airway management in a cervical spine injured patient. Anaesthesiology 1993;78:580-3.
-
(1993)
Anaesthesiology
, vol.78
, pp. 580-583
-
-
Hastings, R.H.1
Kelly, S.D.2
-
3
-
-
0034874984
-
Cervical spine motion during intubation. Efficacy of stabilization manoeuvres in the setting of complete segmental instability
-
L ennarson PJ, Smith DW, Sawin PD, Todd MM, Sato Y, Traynelis VC. Cervical spine motion during intubation. Efficacy of stabilization manoeuvres in the setting of complete segmental instability. J Neurosurg2001;94:265-70.
-
(2001)
J Neurosurg
, vol.94
, pp. 265-270
-
-
Ennarson, P.J.L.1
Smith, D.W.2
Sawin, P.D.3
Todd, M.M.4
Sato, Y.5
Traynelis, V.C.6
-
4
-
-
0033778511
-
Effects of cervical spine immobilization technique & laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation
-
G erling MC, Davis DP, Hamilton RS, Morris GF, Vilke G M, Gartin, et al. Effects of cervical spine immobilization technique & laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation. Ann Emerg Med 2000; 36:293-300.
-
(2000)
Ann Emerg Med
, vol.36
, pp. 293-300
-
-
Erling, M.C.G.1
Davis, D.P.2
Hamilton, R.S.3
Morris, G.F.4
Vilke, G.M.5
Gartin6
-
5
-
-
0027239954
-
Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie
-
Nolan JP, Wilson ME. Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie. Anaesthesia 1993;48:630-3.
-
(1993)
Anaesthesia
, vol.48
, pp. 630-633
-
-
Nolan, J.P.1
Wilson, M.E.2
-
6
-
-
0001143663
-
Reflex Circulatory Responses to Direct Laryngoscopy and Tracheal Intubation performed during General Anaesthesia
-
King BD, Harris LC, Greifenstein FE, Elder JD, Dripps RD. Reflex Circulatory Responses to Direct Laryngoscopy and Tracheal Intubation performed during General Anaesthesia. Anaesthesiology 1951;12:556-66.
-
(1951)
Anaesthesiology
, vol.12
, pp. 556-566
-
-
King, B.D.1
Harris, L.C.2
Greifenstein, F.E.3
Elder, J.D.4
Dripps, R.D.5
-
7
-
-
84867296409
-
-
T ruphatek International Ltd..[Last accessed on D ec 20]
-
T ruphatek International Ltd. TruView EVO2 Optical View Laryngoscope.[Last accessed on 2011 D ec 20] Available at http://www.truphatek. com.
-
(2011)
TruView EVO2 Optical View Laryngoscope
-
-
-
8
-
-
34547116457
-
A comparison of the TruView blade with the Macintosh blade in adult patient
-
Barak M, Philipchuck P, Abecassis P, Katz Y. A comparison of the TruView blade with the Macintosh blade in adult patient. Anaesthesia 2007;62:827-31.
-
(2007)
Anaesthesia
, vol.62
, pp. 827-831
-
-
Barak, M.1
Philipchuck, P.2
Abecassis, P.3
Katz, Y.4
-
9
-
-
0030766142
-
The McCoy levering laryngoscope in patients with limited neck extension
-
Uchida T, Hikawa Y, Saito Y. The McCoy levering laryngoscope in patients with limited neck extension. Can J Anaesth 1997;44:674-6.
-
(1997)
Can J Anaesth
, vol.44
, pp. 674-676
-
-
Uchida, T.1
Hikawa, Y.2
Saito, Y.3
-
11
-
-
0031469105
-
The Intubation Difficulty Scale (IDS); Proposal and Evaluation of a new score characterizing the complexity of endotracheal intubation
-
A dnet F, Borron SW, Racine SX, Clemessy JL, Fournier JL, Plaisance P, et al. The Intubation Difficulty Scale (IDS); Proposal and Evaluation of a new score characterizing the complexity of endotracheal intubation. Anaesthesiology 1997;87:1290-7.
-
(1997)
Anaesthesiology
, vol.87
, pp. 1290-1297
-
-
Dnet, F.A.1
Borron, S.W.2
Racine, S.X.3
Clemessy, J.L.4
Fournier, J.L.5
Plaisance, P.6
-
13
-
-
54249167043
-
Comparison of Macintosh, TruviewEVO2, Glidescope & Airwayscope laryngoscope use in patients with cervical spine immobilization
-
Malik MA, Maharaj CH, Harte BH, Laffey GJ. Comparison of Macintosh, TruviewEVO2, Glidescope & Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008;101:723-30.
-
(2008)
Br J Anaesth
, vol.101
, pp. 723-730
-
-
Malik, M.A.1
Maharaj, C.H.2
Harte, B.H.3
Laffey, G.J.4
-
14
-
-
48349083387
-
TruView EVO2 vs Macintosh laryngoscopy: Study of cardiovascular responses and POGO scoring
-
Khan RM, Maroof M, Jain S, Khan FR, Madhulika M. TruView EVO2 vs Macintosh laryngoscopy: Study of cardiovascular responses and POGO scoring. J Anaesthesiol Clin Pharmacol 2008;24:3113-4.
-
(2008)
J Anaesthesiol Clin Pharmacol
, vol.24
, pp. 3113-3114
-
-
Khan, R.M.1
Maroof, M.2
Jain, S.3
Khan, F.R.4
Madhulika, M.5
-
15
-
-
0029925208
-
The use of the McCoy laryngoscope in patients with simulated cervical spine injuries
-
L aurent SC, de Melo AE, Alexander Williams JM. The use of the McCoy laryngoscope in patients with simulated cervical spine injuries. Anaesthesia 1996;51:74-5.
-
(1996)
Anaesthesia
, vol.51
, pp. 74-75
-
-
Aurent, S.C.L.1
De Melo, A.E.2
Alexander Williams, J.M.3
-
16
-
-
0029790673
-
Laryngoscopy using the McCoy laryngoscope after application of a cervical collar
-
G abbott DA. Laryngoscopy using the McCoy laryngoscope after application of a cervical collar. Anaesthesia 2007;51:812-4.
-
(2007)
Anaesthesia
, vol.51
, pp. 812-814
-
-
Gabbott, D.A.1
|