-
1
-
-
34247476453
-
Elastic moduli of normal and pathological human breast tissues: An inversion-technique-based investigation of 169 samples
-
10.1088/0031-9155/52/6/002
-
A. Samani, J. Zubovits, and D. Plewes, Elastic moduli of normal and pathological human breast tissues: An inversion-technique-based investigation of 169 samples., Phys. Med. Biol. 52 (6), 1565-1576 (2007). 10.1088/0031-9155/52/ 6/002
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.6
, pp. 1565-1576
-
-
Samani, A.1
Zubovits, J.2
Plewes, D.3
-
2
-
-
46049100990
-
Magnetic resonance elastography for the noninvasive staging of liver fibrosis
-
10.1053/j.gastro.2008.03.076
-
L. Huwart, Magnetic resonance elastography for the noninvasive staging of liver fibrosis., Gastroenterology 135 (1), 32-40 (2008). 10.1053/j.gastro.2008. 03.076
-
(2008)
Gastroenterology
, vol.135
, Issue.1
, pp. 32-40
-
-
Huwart, L.1
-
3
-
-
71849119020
-
MR-elastography reveals degradation of tissue integrity in multiple sclerosis
-
10.1016/j.neuroimage.2009.06.018
-
J. Wuerfel, F. Paul, B. Beierbach, U. Hamhaber, D. Klatt, S. Papazoglou, F. Zipp, P. Martus, J. Braun, and I. Sack, MR-elastography reveals degradation of tissue integrity in multiple sclerosis., Neuroimage 49 (3), 2520-2525 (2010). 10.1016/j.neuroimage.2009.06.018
-
(2010)
Neuroimage
, vol.49
, Issue.3
, pp. 2520-2525
-
-
Wuerfel, J.1
Paul, F.2
Beierbach, B.3
Hamhaber, U.4
Klatt, D.5
Papazoglou, S.6
Zipp, F.7
Martus, P.8
Braun, J.9
Sack, I.10
-
4
-
-
36849035742
-
MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography
-
10.1002/mrm.21404
-
R. Sinkus, K. Siegmann, T. Xydeas, M. Tanter, C. Claussen, and M. Fink, MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography., Magn. Reson. Med. 58 (6), 1135-1144 (2007). 10.1002/mrm.21404
-
(2007)
Magn. Reson. Med.
, vol.58
, Issue.6
, pp. 1135-1144
-
-
Sinkus, R.1
Siegmann, K.2
Xydeas, T.3
Tanter, M.4
Claussen, C.5
Fink, M.6
-
5
-
-
79959601936
-
In vivo viscoelastic properties of the brain in normal pressure hydrocephalus
-
10.1002/nbm.1602
-
K.-J. Streitberger, E. Wiener, J. Hoffmann, F. B. Freimann, D. Klatt, J. Braun, K. Lin, J. McLaughlin, C. Sprung, R. Klingebiel, and I. Sack, In vivo viscoelastic properties of the brain in normal pressure hydrocephalus., NMR Biomed. 24 (4), 385-392 (2010). 10.1002/nbm.1602
-
(2010)
NMR Biomed.
, vol.24
, Issue.4
, pp. 385-392
-
-
Streitberger, K.-J.1
Wiener, E.2
Hoffmann, J.3
Freimann, F.B.4
Klatt, D.5
Braun, J.6
Lin, K.7
McLaughlin, J.8
Sprung, C.9
Klingebiel, R.10
Sack, I.11
-
6
-
-
0035779716
-
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
-
10.1016/S1361-8415(00)00039-6
-
A. Manduca, T. E. Oliphant, M. A. Dresner, J. L. Mahowald, S. A. Kruse, E. Amromin, J. P. Felmlee, J. F. Greenleaf, and R. L. Ehman, Magnetic resonance elastography: Non-invasive mapping of tissue elasticity., Med. Image Anal. 5 (4), 237-254 (2001). 10.1016/S1361-8415(00)00039-6
-
(2001)
Med. Image Anal.
, vol.5
, Issue.4
, pp. 237-254
-
-
Manduca, A.1
Oliphant, T.E.2
Dresner, M.A.3
Mahowald, J.L.4
Kruse, S.A.5
Amromin, E.6
Felmlee, J.P.7
Greenleaf, J.F.8
Ehman, R.L.9
-
7
-
-
0035146230
-
Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation
-
10.1002/1522-2594(200102)45:2<299::AID-MRM1039>3.0.CO;2-O
-
T. E. Oliphant, A. Manduca, R. L. Ehman, and J. F. Greenleaf, Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation., Magn. Reson. Med. 45, 299-310 (2001). 10.1002/1522-2594(200102)45:2<299::AID-MRM1039>3.0.CO;2-O
-
(2001)
Magn. Reson. Med.
, vol.45
, pp. 299-310
-
-
Oliphant, T.E.1
Manduca, A.2
Ehman, R.L.3
Greenleaf, J.F.4
-
8
-
-
0034131164
-
High-resolution tensor MR elastography for breast tumour detection
-
10.1088/0031-9155/45/6/317
-
R. Sinkus, J. Lorenzen, D. Schrader, M. Lorenzen, M. Dargatz, and D. Holz, High-resolution tensor MR elastography for breast tumour detection., Phys. Med. Biol. 45 (6), 1649-1664 (2000). 10.1088/0031-9155/45/6/317
-
(2000)
Phys. Med. Biol.
, vol.45
, Issue.6
, pp. 1649-1664
-
-
Sinkus, R.1
Lorenzen, J.2
Schrader, D.3
Lorenzen, M.4
Dargatz, M.5
Holz, D.6
-
9
-
-
12844260217
-
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance elastography
-
10.1002/mrm.20355
-
R. Sinkus, M. Tanter, S. Catheline, J. Lorenzen, C. Kuhl, E. Sondermann, and M. Fink, Imaging anisotropic and viscous properties of breast tissue by magnetic resonance elastography., Magn. Reson. Med. 53, 372-387 (2005). 10.1002/mrm.20355
-
(2005)
Magn. Reson. Med.
, vol.53
, pp. 372-387
-
-
Sinkus, R.1
Tanter, M.2
Catheline, S.3
Lorenzen, J.4
Kuhl, C.5
Sondermann, E.6
Fink, M.7
-
10
-
-
45949108871
-
Algebraic helmholtz inversion in planar magnetic resonance elastography
-
10.1088/0031-9155/53/12/005
-
S. Papazoglou, U. Hamhaber, J. Braun, and I. Sack, Algebraic helmholtz inversion in planar magnetic resonance elastography., Phys. Med. Biol. 53, 3147 (2008). 10.1088/0031-9155/53/12/005
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 3147
-
-
Papazoglou, S.1
Hamhaber, U.2
Braun, J.3
Sack, I.4
-
11
-
-
0036031123
-
Characterization and evaluation of inversion algorithms for MR elastography
-
10.1117/12.467076
-
A. Manduca, Characterization and evaluation of inversion algorithms for MR elastography., Proc. SPIE 4684, 1180-1185 (2002). 10.1117/12.467076
-
(2002)
Proc. SPIE
, vol.4684
, pp. 1180-1185
-
-
Manduca, A.1
-
12
-
-
0035040724
-
Three-dimensional subzone-based reconstruction algorithm for MR elastography
-
10.1002/mrm.1111
-
E. E. W. Van Houten, M. I. Miga, J. B. Weaver, F. E. Kennedy, and K. D. Paulsen, Three-dimensional subzone-based reconstruction algorithm for MR elastography., Magn. Reson. Med. 45, 827-837 (2001). 10.1002/mrm.1111
-
(2001)
Magn. Reson. Med.
, vol.45
, pp. 827-837
-
-
Van Houten, E.E.W.1
Miga, M.I.2
Weaver, J.B.3
Kennedy, F.E.4
Paulsen, K.D.5
-
13
-
-
19044390617
-
A three-parameter mechanical property reconstruction method for MR-based elastic property imaging
-
10.1109/TMI.2004.842451
-
E. E. W. Van Houten, M. M. Doyley, F. E. Kennedy, K. D. Paulsen, and J. B. Weaver, A three-parameter mechanical property reconstruction method for MR-based elastic property imaging., IEEE Trans. Med. Imaging 24, 311-324 (2005). 10.1109/TMI.2004.842451
-
(2005)
IEEE Trans. Med. Imaging
, vol.24
, pp. 311-324
-
-
Van Houten, E.E.W.1
Doyley, M.M.2
Kennedy, F.E.3
Paulsen, K.D.4
Weaver, J.B.5
-
14
-
-
0034857903
-
Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion
-
10.1118/1.1386776
-
J. B. Weaver, E. E. W. Van Houten, M. I. Miga, F. E. Kennedy, and K. D. Paulsen, Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion., Med. Phys. 28, 311-324 (2001). 10.1118/1.1386776
-
(2001)
Med. Phys.
, vol.28
, pp. 311-324
-
-
Weaver, J.B.1
Van Houten, E.E.W.2
Miga, M.I.3
Kennedy, F.E.4
Paulsen, K.D.5
-
15
-
-
17044414054
-
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
-
10.1016/j.mri.2004.11.060
-
R. Sinkus, M. Tanter, T. Xydeas, S. Catheline, J. Bercoff, and M. Fink, Viscoelastic shear properties of in vivo breast lesions measured by MR elastography., Magn. Reson. Imaging 23, 159-165 (2005). 10.1016/j.mri.2004.11. 060
-
(2005)
Magn. Reson. Imaging
, vol.23
, pp. 159-165
-
-
Sinkus, R.1
Tanter, M.2
Xydeas, T.3
Catheline, S.4
Bercoff, J.5
Fink, M.6
-
16
-
-
70350516134
-
Science to Practice: Can MR Elastography Be Used to Detect Early Steatohepatitis in Fatty Liver Disease?
-
10.1148/radiol.2531091040
-
R. L. Ehman, Science to Practice: Can MR Elastography Be Used to Detect Early Steatohepatitis in Fatty Liver Disease?, Radiology 253 (1), 1-3 (2009). 10.1148/radiol.2531091040
-
(2009)
Radiology
, vol.253
, Issue.1
, pp. 1-3
-
-
Ehman, R.L.1
-
17
-
-
80051922881
-
Decreased brain stiffness in alzheimers disease determined by magnetic resonance elastography
-
10.1002/jmri.22707
-
M. C. Murphy, J. Huston, C. R. Jack, K. J. Glaser, A. Manduca, J. P. Felmlee, and R. L. Ehman, Decreased brain stiffness in alzheimers disease determined by magnetic resonance elastography., J. Magn. Reson. Imaging 498, 494-498 (2011). 10.1002/jmri.22707
-
(2011)
J. Magn. Reson. Imaging
, vol.498
, pp. 494-498
-
-
Murphy, M.C.1
Huston, J.2
Jack, C.R.3
Glaser, K.J.4
Manduca, A.5
Felmlee, J.P.6
Ehman, R.L.7
-
18
-
-
41949121082
-
Non-invasive measurement of brain viscoelasticity using magnetic resonance elastography
-
10.1002/nbm.1189
-
I. Sack, B. Beierbach, U. Hamhaber, D. Klatt, and J. Braun, Non-invasive measurement of brain viscoelasticity using magnetic resonance elastography., NMR Biomed. 21 (3), 37-41 (2008). 10.1002/nbm.1189
-
(2008)
NMR Biomed.
, vol.21
, Issue.3
, pp. 37-41
-
-
Sack, I.1
Beierbach, B.2
Hamhaber, U.3
Klatt, D.4
Braun, J.5
-
19
-
-
77951236852
-
Diagnostic value of MR elastography in addition to contrast-enhanced MR imaging of the breast-initial clinical results
-
10.1007/s00330-009-1566-4
-
K. C. Siegmann, T. Xydeas, R. Sinkus, B. Kraemer, U. Vogel, and C. D. Claussen, Diagnostic value of MR elastography in addition to contrast-enhanced MR imaging of the breast-initial clinical results., Eur. Radiol. 20 (2), 318-25 (2010). 10.1007/s00330-009-1566-4
-
(2010)
Eur. Radiol.
, vol.20
, Issue.2
, pp. 318-325
-
-
Siegmann, K.C.1
Xydeas, T.2
Sinkus, R.3
Kraemer, B.4
Vogel, U.5
Claussen, C.D.6
-
20
-
-
50049102447
-
In vivo brain viscoelastic properties measured by magnetic resonance elastography
-
10.1002/nbm.1254
-
M. A. Green, L. E. Bilston, and R. Sinkus, In vivo brain viscoelastic properties measured by magnetic resonance elastography., NMR Biomed. 21 (7), 755-764 (2008). 10.1002/nbm.1254
-
(2008)
NMR Biomed.
, vol.21
, Issue.7
, pp. 755-764
-
-
Green, M.A.1
Bilston, L.E.2
Sinkus, R.3
-
21
-
-
84867288750
-
Investigating anisotropic elasticity using MR-elastography combined with diffusion tensor imaging: Validation using anisotropic and viscoelastic phantoms
-
E. C. Qin, R. Sinkus, C. Rae, and L. E. Bilston, Investigating anisotropic elasticity using MR-elastography combined with diffusion tensor imaging: Validation using anisotropic and viscoelastic phantoms., Proc. Intl. Soc. Mag. Reson. Med. 19, 39 (2011).
-
(2011)
Proc. Intl. Soc. Mag. Reson. Med.
, vol.19
, pp. 39
-
-
Qin, E.C.1
Sinkus, R.2
Rae, C.3
Bilston, L.E.4
-
22
-
-
79953651341
-
Subzone based magnetic resonance elastography using a Rayleigh damped material model
-
10.1118/1.3557469
-
E. E. W. Van Houten, D. vR. Viviers, M. D. J. McGarry, P. R. Perriñez, I. I. Perreard, J. B. Weaver, and K. D. Paulsen, Subzone based magnetic resonance elastography using a Rayleigh damped material model., Med. Phys. 38 (4), 1993-2004 (2011). 10.1118/1.3557469
-
(2011)
Med. Phys.
, vol.38
, Issue.4
, pp. 1993-2004
-
-
Van Houten, E.E.W.1
Viviers, D.R.2
McGarry, M.D.J.3
Perriñez, P.R.4
Perreard, I.I.5
Weaver, J.B.6
Paulsen, K.D.7
-
23
-
-
84857825381
-
Estimating hydraulic conductivity in vivo using magnetic resonance elastography
-
10.1007/978-1-4614-0219-0-5
-
A. J. Pattison, P. R. Perrinez, M. D. J. McGarry, J. B. Weaver, and K. D. Paulsen, Estimating hydraulic conductivity in vivo using magnetic resonance elastography., Mech. Biol. Syst. Mater. 2, 41-48 (2011). 10.1007/978-1-4614- 0219-0-5
-
(2011)
Mech. Biol. Syst. Mater.
, vol.2
, pp. 41-48
-
-
Pattison, A.J.1
Perrinez, P.R.2
McGarry, M.D.J.3
Weaver, J.B.4
Paulsen, K.D.5
-
24
-
-
0032833522
-
An overlapping subzone technique for MR-based elastic property reconstruction
-
10.1002/(SICI)1522-2594(199910)42:4<779::AID-MRM21>3.0.CO;2-Z
-
E. E. W. Van Houten, K. D. Paulsen, M. I. Miga, F. E. Kennedy, and J. B. Weaver, An overlapping subzone technique for MR-based elastic property reconstruction., Magn. Reson. Med. 42, 779-786 (1999). 10.1002/(SICI)1522- 2594(199910)42:4<779::AID-MRM21>3.0.CO;2-Z
-
(1999)
Magn. Reson. Med.
, vol.42
, pp. 779-786
-
-
Van Houten, E.E.W.1
Paulsen, K.D.2
Miga, M.I.3
Kennedy, F.E.4
Weaver, J.B.5
-
25
-
-
0000462034
-
Enhanced frequency-domain optical image reconstruction in tissues through total-variation minimization
-
10.1364/AO.35.003447
-
K. D. Paulsen and H. Jiang, Enhanced frequency-domain optical image reconstruction in tissues through total-variation minimization., Appl. Opt. 35 (19), 3447-3458 (1996). 10.1364/AO.35.003447
-
(1996)
Appl. Opt.
, vol.35
, Issue.19
, pp. 3447-3458
-
-
Paulsen, K.D.1
Jiang, H.2
-
26
-
-
39749096379
-
-
(Butterworth-Heinemann, Oxford, UK).
-
O. C. Zienkiewicz and R. L. Taylor, The Finite Element Method. Vol. 1, The Basis (Butterworth-Heinemann, Oxford, UK, 2000).
-
(2000)
The Finite Element Method. Vol. 1, the Basis
-
-
Zienkiewicz, O.C.1
Taylor, R.L.2
-
27
-
-
78149478584
-
The performance of steady-state harmonic magnetic resonance elastography when applied to viscoelastic materials
-
10.1118/1.3454738
-
M. M. Doyley, I. Perreard, A. J. Patterson, J. B. Weaver, and K. M. Paulsen, The performance of steady-state harmonic magnetic resonance elastography when applied to viscoelastic materials., Med. Phys. 37, 3970-3979 (2010). 10.1118/1.3454738
-
(2010)
Med. Phys.
, vol.37
, pp. 3970-3979
-
-
Doyley, M.M.1
Perreard, I.2
Patterson, A.J.3
Weaver, J.B.4
Paulsen, K.M.5
-
28
-
-
84878142715
-
Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction
-
(accepted). 10.1002/mrm.24473
-
C. L. Johnson, M. D. J. McGarry, E. E. W. Van Houten, J. B. Weaver, K. D. Paulsen, B. P. Sutton, and J. G. Georgiadis, Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction., Magnetic Resonance in Medicine (accepted). 10.1002/mrm.24473
-
Magnetic Resonance in Medicine
-
-
Johnson, C.L.1
McGarry, M.D.J.2
Van Houten, E.E.W.3
Weaver, J.B.4
Paulsen, K.D.5
Sutton, B.P.6
Georgiadis, J.G.7
-
29
-
-
84867285366
-
High-resolution multishot MR elastography of the brain with correction for motion-induced phase errors
-
C. L. Johnson, M. D. Mcgarry, A. A. Gharibans, J. B. Weaver, K. D. Paulsen, B. P. Sutton, and J. G. Georgiadis, High-resolution multishot MR elastography of the brain with correction for motion-induced phase errors., Proc. Intl. Soc. Mag. Reson. Med. 20, 2517 (2012).
-
(2012)
Proc. Intl. Soc. Mag. Reson. Med.
, vol.20
, pp. 2517
-
-
Johnson, C.L.1
McGarry, M.D.2
Gharibans, A.A.3
Weaver, J.B.4
Paulsen, K.D.5
Sutton, B.P.6
Georgiadis, J.G.7
-
30
-
-
79960352917
-
An octahedral shear strain-based measure of SNR for 3D MR elastography
-
10.1088/0031-9155/56/13/N02
-
M. D. J. McGarry, E. E. W. Van Houten, P. R. Perriñez, A. J. Pattison, J. B. Weaver, and K. D. Paulsen, An octahedral shear strain-based measure of SNR for 3D MR elastography., Phys. Med. Biol. 56, N153-N164 (2011). 10.1088/0031-9155/56/13/N02
-
(2011)
Phys. Med. Biol.
, vol.56
-
-
McGarry, M.D.J.1
Van Houten, E.E.W.2
Perriñez, P.R.3
Pattison, A.J.4
Weaver, J.B.5
Paulsen, K.D.6
-
31
-
-
64949170822
-
The impact of aging and gender on brain viscoelasticity
-
10.1016/j.neuroimage.2009.02.040
-
I. Sack, B. Beierbach, J. Wuerfel, D. Klatt, U. Hamhaber, S. Papazoglou, P. Martus, and J. Braun, The impact of aging and gender on brain viscoelasticity., Neuroimage 46 (3), 652-657 (2009). 10.1016/j.neuroimage.2009. 02.040
-
(2009)
Neuroimage
, vol.46
, Issue.3
, pp. 652-657
-
-
Sack, I.1
Beierbach, B.2
Wuerfel, J.3
Klatt, D.4
Hamhaber, U.5
Papazoglou, S.6
Martus, P.7
Braun, J.8
-
32
-
-
37549034251
-
MR elastography of the lung with hyperpolarized 3He
-
10.1002/mrm.21465
-
K. P. McGee, R. D. Hubmayr, and R. L. Ehman, MR elastography of the lung with hyperpolarized 3He., Magn. Reson. Med. 59 (1), 14-18 (2008). 10.1002/mrm.21465
-
(2008)
Magn. Reson. Med.
, vol.59
, Issue.1
, pp. 14-18
-
-
McGee, K.P.1
Hubmayr, R.D.2
Ehman, R.L.3
|