Volumn 47, Issue 11, 2012, Pages 642-648

Full field image reconstruction is suitable for high-pitch dual-source computed tomography

Author keywords

computed tomography; dual source CT; field of view; high pitch; image reconstruction

Indexed keywords

AGED; ANALYSIS OF VARIANCE; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HIGH PITCH DUAL SOURCE COMPUTED TOMOGRAPHY; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; MALE; PATIENT CODING; PHANTOM; PRIORITY JOURNAL; RADIATION DETECTOR; RADIOGRAPHY; RADIOLOGIST;

EID: 84867252052     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e31826531ce     Document Type: Article
Times cited : (3)

References (19)
  • 1
    • 72049130251 scopus 로고    scopus 로고
    • Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality
    • Flohr TG, Leng S, Yu L, et al. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality. Med Ph-S. 2009;36:5641-5653.
    • (2009) Med Ph-S , vol.36 , pp. 5641-5653
    • Flohr, T.G.1    Leng, S.2    Yu, L.3
  • 2
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • Achenbach S, Marwan M, Ropers D, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J. 2010; 31:340-346.
    • (2010) Eur Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 3
    • 77952520540 scopus 로고    scopus 로고
    • Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency
    • Goetti R, Leschka S, Baumü ller S, et al. Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency. Invest Radiol. 2010;45:324-330.
    • (2010) Invest Radiol , vol.45 , pp. 324-330
    • Goetti, R.1    Leschka, S.2    Baumüller, S.3
  • 4
    • 84856958470 scopus 로고    scopus 로고
    • Routine chest and abdominal highpitch CT: An alternative low dose protocol with preserved image quality
    • Amacker NA, Mader C, Alkadhi H, et al. Routine chest and abdominal highpitch CT: an alternative low dose protocol with preserved image quality. Eur J Radiol. 2012;81:e392Ye397.
    • (2012) Eur J Radiol , vol.81
    • Amacker, N.A.1    Mader, C.2    Alkadhi, H.3
  • 5
    • 79957825412 scopus 로고    scopus 로고
    • Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: Clinical feasibility study
    • Hardie AD, Mayes N, Boulter DJ. Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: clinical feasibility study. J Comput Assist Tomogr. 2011;35:353-355.
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 353-355
    • Hardie, A.D.1    Mayes, N.2    Boulter, D.J.3
  • 6
    • 84857042898 scopus 로고    scopus 로고
    • High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    • Beeres M, Schell B, Mastragelopoulos A, et al. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience. Eur Radiol. 2012;22:129-137.
    • (2012) Eur Radiol , vol.22 , pp. 129-137
    • Beeres, M.1    Schell, B.2    Mastragelopoulos, A.3
  • 7
    • 79952440432 scopus 로고    scopus 로고
    • Computed tomography of the lung in the high-pitch mode: Is breath holding still required?
    • Baumueller S, Alkadhi H, Stolzmann P, et al. Computed tomography of the lung in the high-pitch mode: is breath holding still required? Invest Radiol. 2011;46: 240-245.
    • (2011) Invest Radiol , vol.46 , pp. 240-245
    • Baumueller, S.1    Alkadhi, H.2    Stolzmann, P.3
  • 8
    • 78751615956 scopus 로고    scopus 로고
    • High-pitch spiral computed tomography: Effect on image quality and radiation dose in pediatric chest computed tomography
    • Lell MM, May M, Deak P, et al. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol. 2011;46:116-123.
    • (2011) Invest Radiol , vol.46 , pp. 116-123
    • Lell, M.M.1    May, M.2    Deak, P.3
  • 9
    • 74949113259 scopus 로고    scopus 로고
    • Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique
    • Sommer WH, Schenzle JC, Becker CR, et al. Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique. Invest Radiol. 2010;45:64-71.
    • (2010) Invest Radiol , vol.45 , pp. 64-71
    • Sommer, W.H.1    Schenzle, J.C.2    Becker, C.R.3
  • 10
    • 84857055684 scopus 로고    scopus 로고
    • Dual source multidetector CTangiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode
    • Wuest W, Anders K, Schuhbaeck A, et al. Dual source multidetector CTangiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol. 2012;22:51-58.
    • (2012) Eur Radiol , vol.22 , pp. 51-58
    • Wuest, W.1    Anders, K.2    Schuhbaeck, A.3
  • 11
    • 77952097970 scopus 로고    scopus 로고
    • Dual-source chest CT angiography with high temporal resolution and high pitch modes: Evaluation of image quality in 140 patients
    • Tacelli N, Remy-Jardin M, Flohr T, et al. Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients. Eur Radiol. 2010;20:1188-1196.
    • (2010) Eur Radiol , vol.20 , pp. 1188-1196
    • Tacelli, N.1    Remy-Jardin, M.2    Flohr, T.3
  • 12
    • 3042821092 scopus 로고    scopus 로고
    • Weighted FBPVa simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch
    • Stierstorfer K, Rauscher A, Boese J, et al.Weighted FBPVa simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch. Ph-S Med Biol. 2004;49:2209-2218.
    • (2004) Ph-S Med Biol , vol.49 , pp. 2209-2218
    • Stierstorfer, K.1    Rauscher, A.2    Boese, J.3
  • 13
    • 56349130541 scopus 로고    scopus 로고
    • Technical principles of dual source CT
    • Petersilka M, Bruder H, Krauss B, et al. Technical principles of dual source CT. Eur J Radiol. 2008;68:362-368.
    • (2008) Eur J Radiol , vol.68 , pp. 362-368
    • Petersilka, M.1    Bruder, H.2    Krauss, B.3
  • 14
    • 0034257864 scopus 로고    scopus 로고
    • Spiral interpolation algorithm for multislice spiral CTVpart I: Theory
    • Schaller S, Flohr T, Klingenbeck K, et al. Spiral interpolation algorithm for multislice spiral CTVpart I: theory. IEEE Trans Med Imaging. 2000;19: 822-834.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 822-834
    • Schaller, S.1    Flohr, T.2    Klingenbeck, K.3
  • 15
    • 0030819048 scopus 로고    scopus 로고
    • Optimal pitch in spiral computed tomography
    • Wang G, VannierMW. Optimal pitch in spiral computed tomography. Med Ph-S. 1997;24:1635-1639.
    • (1997) Med Ph-S , vol.24 , pp. 1635-1639
    • Wang, G.1    Vannier, M.W.2
  • 16
    • 0033954645 scopus 로고    scopus 로고
    • Efficient correction for CT image artifacts caused by objects extending outside the scan field of view
    • Ohnesorge B, Flohr T, Schwarz K, et al. Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. Med Ph-S. 2000;27:39-46.
    • (2000) Med Ph-S , vol.27 , pp. 39-46
    • Ohnesorge, B.1    Flohr, T.2    Schwarz, K.3
  • 17
    • 4644290361 scopus 로고    scopus 로고
    • A novel reconstruction algorithm to extend the CT scan field-of-view
    • Hsieh J, Chao E, Thibault J, et al. A novel reconstruction algorithm to extend the CT scan field-of-view. Med Ph-S. 2004;31:2385-2391.
    • (2004) Med Ph-S , vol.31 , pp. 2385-2391
    • Hsieh, J.1    Chao, E.2    Thibault, J.3
  • 18
    • 79960235728 scopus 로고    scopus 로고
    • Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning
    • Wu V, Podgorsak MB, Tran TA, et al. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning. Med Ph-S. 2011;38: 4451-4463.
    • (2011) Med Ph-S. , vol.38 , pp. 4451-4463
    • Wu, V.1    Podgorsak, M.B.2    Tran, T.A.3
  • 19
    • 68249135880 scopus 로고    scopus 로고
    • Experience converting an RT department to full CT simulation: Technical issues identified during commissioning of a wide-bore scanner
    • Ebert MA, Kenny J, Greer PB. Experience converting an RT department to full CT simulation: technical issues identified during commissioning of a wide-bore scanner. J Med Imaging Radiat Oncol. 2009;53:325-330.
    • (2009) J Med Imaging Radiat Oncol , vol.53 , pp. 325-330
    • Ebert, M.A.1    Kenny, J.2    Greer, P.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.