메뉴 건너뛰기




Volumn 439, Issue , 2012, Pages 150-157

Evaluation of a newly developed diffusion denuder for atmospheric aerosol separation from co-pollutant gases

Author keywords

Annular diffusion denuder; Carbon monoxide; Combustion aerosol; Non selective membrane; Sampling artifact

Indexed keywords

AMBIENT AIR; AMBIENT CONDITIONS; ANNULAR TUBES; CHEMICAL ADSORPTION; COMBUSTION SOURCES; CONDENSATION PARTICLE COUNTERS; CONTROLLED LABORATORIES; DENUDERS; GAS REMOVAL; HIGHER EFFICIENCY; PERFORMANCE EVALUATION; REMOVAL EFFICIENCIES; SAMPLING ARTIFACTS; SINGLE STAGE; SOOT PARTICLES; SUB-MICRON PARTICLES; TRANSMISSION EFFICIENCY; ULTRAFINE;

EID: 84867236806     PISSN: 00489697     EISSN: 18791026     Source Type: Journal    
DOI: 10.1016/j.scitotenv.2012.09.029     Document Type: Article
Times cited : (3)

References (26)
  • 2
    • 0024472515 scopus 로고
    • Evaluation of the gas collection of an annular denuder system under simulated atmospheric conditions
    • Brauer M., Koutrakis P., Wolfson J.M., Spengler J.D. Evaluation of the gas collection of an annular denuder system under simulated atmospheric conditions. Atmos Environ 1989, 23:1981-1986.
    • (1989) Atmos Environ , vol.23 , pp. 1981-1986
    • Brauer, M.1    Koutrakis, P.2    Wolfson, J.M.3    Spengler, J.D.4
  • 4
    • 75349106255 scopus 로고    scopus 로고
    • Assessment of personal exposure to inhalable indoor and outdoor particulate matter for student residents of an academic campus (IIT-Kanpur)
    • Devi J., Gupta T., Tripathi S.N., Ujinwal K.K. Assessment of personal exposure to inhalable indoor and outdoor particulate matter for student residents of an academic campus (IIT-Kanpur). Inhal Toxicol 2009, 21:1208-1222.
    • (2009) Inhal Toxicol , vol.21 , pp. 1208-1222
    • Devi, J.1    Gupta, T.2    Tripathi, S.N.3    Ujinwal, K.K.4
  • 5
    • 0000817431 scopus 로고
    • Diffusion from a stream flowing through a cylindrical tube
    • Gormley P.G., Kennedy M. Diffusion from a stream flowing through a cylindrical tube. Proc R Ir Acad 1949, 52A:163-169.
    • (1949) Proc R Ir Acad , vol.52 A , pp. 163-169
    • Gormley, P.G.1    Kennedy, M.2
  • 7
    • 0004119084 scopus 로고    scopus 로고
    • John Wiley & Sons Inc., New York
    • Hinds W.C. Aerosol technology 1999, John Wiley & Sons Inc., New York.
    • (1999) Aerosol technology
    • Hinds, W.C.1
  • 10
    • 0027337143 scopus 로고
    • Membrane-based gas separation
    • Koros W.J., Fleming G.K. Membrane-based gas separation. J Membr Sci 1993, 83:1-80.
    • (1993) J Membr Sci , vol.83 , pp. 1-80
    • Koros, W.J.1    Fleming, G.K.2
  • 11
    • 77957716877 scopus 로고    scopus 로고
    • An online parallel-plate wet denuder system for monitoring acetic acid gas
    • Ku Y.P., Yang C., Lin G.Y., Tsai C.J. An online parallel-plate wet denuder system for monitoring acetic acid gas. Aerosol Air Qual Res 2010, 10:479-488.
    • (2010) Aerosol Air Qual Res , vol.10 , pp. 479-488
    • Ku, Y.P.1    Yang, C.2    Lin, G.Y.3    Tsai, C.J.4
  • 12
    • 38549083010 scopus 로고
    • The Stokes-Einstein law for diffusion in solution
    • Miller C.C. The Stokes-Einstein law for diffusion in solution. Proc R Soc Lond A 1924, 106:724-749.
    • (1924) Proc R Soc Lond A , vol.106 , pp. 724-749
    • Miller, C.C.1
  • 14
    • 57949114029 scopus 로고    scopus 로고
    • Experimental testing of an annular denuder and filter system to measure gas-particle partitioning of semivolatile bifunctional carbonyls in the atmosphere
    • Ortiz R., Enya K., Sekiguchi K., Sakamoto K. Experimental testing of an annular denuder and filter system to measure gas-particle partitioning of semivolatile bifunctional carbonyls in the atmosphere. Atmos Environ 2009, 43:382-388.
    • (2009) Atmos Environ , vol.43 , pp. 382-388
    • Ortiz, R.1    Enya, K.2    Sekiguchi, K.3    Sakamoto, K.4
  • 15
    • 0025075887 scopus 로고
    • Laboratory tests of KI and alkaline annular denuders
    • Parmar S.S., Grosjean D. Laboratory tests of KI and alkaline annular denuders. Atmos Environ 1990, 24A:2695-2698.
    • (1990) Atmos Environ , vol.24 A , pp. 2695-2698
    • Parmar, S.S.1    Grosjean, D.2
  • 16
    • 0028464059 scopus 로고
    • A compact porous-metal denuder for atmospheric sampling of inorganic aerosols
    • Poon W.S., Pui Y.H., Lee C.T., Liu B.Y.H. A compact porous-metal denuder for atmospheric sampling of inorganic aerosols. J Aerosol Sci 1994, 25:923-934.
    • (1994) J Aerosol Sci , vol.25 , pp. 923-934
    • Poon, W.S.1    Pui, Y.H.2    Lee, C.T.3    Liu, B.Y.H.4
  • 17
    • 1342286107 scopus 로고    scopus 로고
    • Determination of phase-distributed PAH in Rome ambient air by denuder/GC-MS method
    • Possanzini M., Palo V.D., Gigliucci P., Sciano M.C.T., Cecinato A. Determination of phase-distributed PAH in Rome ambient air by denuder/GC-MS method. Atmos Environ 2004, 38:1727-1734.
    • (2004) Atmos Environ , vol.38 , pp. 1727-1734
    • Possanzini, M.1    Palo, V.D.2    Gigliucci, P.3    Sciano, M.C.T.4    Cecinato, A.5
  • 18
    • 0034843050 scopus 로고    scopus 로고
    • Laboratory and field investigations of a new and simple design for the parallel plate denuder
    • Rosman K., Shimmo M., Karlsson A., Hansson H.C., Keronen P., Allen A., et al. Laboratory and field investigations of a new and simple design for the parallel plate denuder. Atmos Environ 2001, 35:5301-5310.
    • (2001) Atmos Environ , vol.35 , pp. 5301-5310
    • Rosman, K.1    Shimmo, M.2    Karlsson, A.3    Hansson, H.C.4    Keronen, P.5    Allen, A.6
  • 19
    • 1642504242 scopus 로고    scopus 로고
    • Evaluation of an annular denuder for atmospheric PAH partitioning studies-2: evaluation of mass and number particle losses
    • Roussel B.T., Monod A., Massiani C., Wortham H. Evaluation of an annular denuder for atmospheric PAH partitioning studies-2: evaluation of mass and number particle losses. Atmos Environ 2004, 38:1925-1932.
    • (2004) Atmos Environ , vol.38 , pp. 1925-1932
    • Roussel, B.T.1    Monod, A.2    Massiani, C.3    Wortham, H.4
  • 20
    • 33747454254 scopus 로고    scopus 로고
    • A counter-current parallel-plate membrane denuder for the non-specific removal of trace gases
    • Ruiz P.A., Lawrence J.E., Perguson S.T., Wolfson J.M., Koutrakis P. A counter-current parallel-plate membrane denuder for the non-specific removal of trace gases. Environ Sci Technol 2006, 40:5058-5063.
    • (2006) Environ Sci Technol , vol.40 , pp. 5058-5063
    • Ruiz, P.A.1    Lawrence, J.E.2    Perguson, S.T.3    Wolfson, J.M.4    Koutrakis, P.5
  • 21
    • 0029663032 scopus 로고    scopus 로고
    • Simultaneous determination of nitrogen dioxide and peroxyacetyl nitrate in ambient atmosphere by carbon-coated annular diffusion denuder
    • Santis F.D., Allegrini I., Filippo P.D., Pasella D. Simultaneous determination of nitrogen dioxide and peroxyacetyl nitrate in ambient atmosphere by carbon-coated annular diffusion denuder. Atmos Environ 1996, 30:2637-2645.
    • (1996) Atmos Environ , vol.30 , pp. 2637-2645
    • Santis, F.D.1    Allegrini, I.2    Filippo, P.D.3    Pasella, D.4
  • 23
    • 0029667141 scopus 로고    scopus 로고
    • Laboratory and field evaluation of an improved glass honeycomb denuder/filter pack sampler
    • Sioutas, Wang P.Y., Ferguson S.T., Koutrakis P., Mulik J.D. Laboratory and field evaluation of an improved glass honeycomb denuder/filter pack sampler. Atmos Environ 1996, 30:885-895.
    • (1996) Atmos Environ , vol.30 , pp. 885-895
    • Sioutas1    Wang, P.Y.2    Ferguson, S.T.3    Koutrakis, P.4    Mulik, J.D.5
  • 24
    • 0028501787 scopus 로고
    • Polymers for gas separations: the next decade
    • Stern S.A. Polymers for gas separations: the next decade. J Membr Sci 1994, 94:1-65.
    • (1994) J Membr Sci , vol.94 , pp. 1-65
    • Stern, S.A.1
  • 25
    • 0026089344 scopus 로고
    • Particle transmission characteristics of an annular denuder ambient sampling system
    • Ye Y., Tsai C.J., Pui Y.H., Lewis C.W. Particle transmission characteristics of an annular denuder ambient sampling system. Aerosol Sci Technol 1991, 14:102-111.
    • (1991) Aerosol Sci Technol , vol.14 , pp. 102-111
    • Ye, Y.1    Tsai, C.J.2    Pui, Y.H.3    Lewis, C.W.4
  • 26
    • 0026053154 scopus 로고
    • Design of a straight inlet diffusion scrubber. Comparison of particle transmission with other collection devices and characterization for the measurement of hydrogen peroxide and formaldehyde
    • Zhang G., Dasgupta P.K., Cheng Y.S. Design of a straight inlet diffusion scrubber. Comparison of particle transmission with other collection devices and characterization for the measurement of hydrogen peroxide and formaldehyde. Atmos Environ 1991, 25A:2717-2729.
    • (1991) Atmos Environ , vol.25 A , pp. 2717-2729
    • Zhang, G.1    Dasgupta, P.K.2    Cheng, Y.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.