메뉴 건너뛰기




Volumn 10, Issue 4, 2012, Pages 287-292

Monitoring sleep with a smartphone accelerometer

Author keywords

Accelerometer; Actigraph; Algorithm; Sleep; Smartphone; Wake

Indexed keywords

ACCELEROMETER; ACTIGRAPH ACCELEROMETER; ACTIMETRY; ADULT; ARTICLE; DATA ANALYSIS SOFTWARE; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; MOBILE PHONE; NORMAL HUMAN; PRIORITY JOURNAL; SLEEP; SLEEP EFFICIENCY; SLEEP INDUCTION; SLEEP ONSET LATENCY; SLEEP PARAMETERS; SLEEP TIME; SLEEP WAKING CYCLE; SMARTPHONE ACCELEROMETER; TOTAL SLEEP TIME; WAKE AFTER SLEEP ONSET; WAKEFULNESS;

EID: 84867140322     PISSN: 14469235     EISSN: 14798425     Source Type: Journal    
DOI: 10.1111/j.1479-8425.2012.00575.x     Document Type: Article
Times cited : (62)

References (15)
  • 1
    • 72649100217 scopus 로고    scopus 로고
    • Insomnia and health-related quality of life
    • Kyle SD, Morgan K, Espie CA. Insomnia and health-related quality of life. Sleep Med. Rev. 2010; 14: 69-82.
    • (2010) Sleep Med. Rev. , vol.14 , pp. 69-82
    • Kyle, S.D.1    Morgan, K.2    Espie, C.A.3
  • 2
    • 0036526075 scopus 로고    scopus 로고
    • Epidemiology of insomnia: what we know and what we still need to learn
    • Ohayon MM. Epidemiology of insomnia: what we know and what we still need to learn. Sleep Med. Rev. 2002; 6: 97-111.
    • (2002) Sleep Med. Rev. , vol.6 , pp. 97-111
    • Ohayon, M.M.1
  • 3
    • 0043065577 scopus 로고    scopus 로고
    • Accuracy of sleep perceptions among insomnia sufferers and normal sleepers
    • Means K, Edinger JD, Glenn DM, Fins AI. Accuracy of sleep perceptions among insomnia sufferers and normal sleepers. Sleep Med. 2003; 4: 285-96.
    • (2003) Sleep Med. , vol.4 , pp. 285-296
    • Means, K.1    Edinger, J.D.2    Glenn, D.M.3    Fins, A.I.4
  • 4
    • 79751469894 scopus 로고    scopus 로고
    • Objective measurements of sleep for non-laboratory settings as alternatives to polysomnography - a systematic review
    • Van de Water ATM, Holems A, Hurley DA. Objective measurements of sleep for non-laboratory settings as alternatives to polysomnography - a systematic review. J. Sleep Res. 2011; 20: 183-200.
    • (2011) J. Sleep Res. , vol.20 , pp. 183-200
    • Van de Water, A.T.M.1    Holems, A.2    Hurley, D.A.3
  • 6
    • 0014959493 scopus 로고
    • Psychiatric illness in general practice: a detailed study using a new method of case identification
    • Goldberg DP, Blackwell B. Psychiatric illness in general practice: a detailed study using a new method of case identification. Br. Med. J. 1970; 2: 439-43.
    • (1970) Br. Med. J. , vol.2 , pp. 439-443
    • Goldberg, D.P.1    Blackwell, B.2
  • 7
    • 84867140799 scopus 로고    scopus 로고
    • Validation with Polysomnography of the Sleepwatch Sleep/Wake Scoring Algorithm used by the Actiwatch Activity Monitoring System. Technical report, Bend, Ore., Mini-Mitter
    • Oakley NR. Validation with Polysomnography of the Sleepwatch Sleep/Wake Scoring Algorithm used by the Actiwatch Activity Monitoring System. Technical report, Bend, Ore., Mini-Mitter, 1997.
    • (1997)
    • Oakley, N.R.1
  • 8
    • 39749104115 scopus 로고    scopus 로고
    • Comparison of two different actigraphs with polysomnography in healthy young subjects
    • Tonetti L, Pasquini F, Fabbri M, Belluzzi M, Natale V. Comparison of two different actigraphs with polysomnography in healthy young subjects. Chronobiol. Int. 2008; 25: 145-53.
    • (2008) Chronobiol. Int. , vol.25 , pp. 145-153
    • Tonetti, L.1    Pasquini, F.2    Fabbri, M.3    Belluzzi, M.4    Natale, V.5
  • 9
    • 67349234126 scopus 로고    scopus 로고
    • Evaluation of immobility time for sleep latency in actigraphy
    • Chae KY, Kripke DF, Poceta JS etal. Evaluation of immobility time for sleep latency in actigraphy. Sleep Med. 2009; 10: 621-5.
    • (2009) Sleep Med. , vol.10 , pp. 621-625
    • Chae, K.Y.1    Kripke, D.F.2    Poceta, J.S.3
  • 11
    • 77958567458 scopus 로고    scopus 로고
    • Wrist actigraphic scoring for sleep laboratory patients: algorhythm development
    • Kripke DF, Hahn EK, Grizas AP etal. Wrist actigraphic scoring for sleep laboratory patients: algorhythm development. J. Sleep Res. 2010; 19: 612-19.
    • (2010) J. Sleep Res. , vol.19 , pp. 612-619
    • Kripke, D.F.1    Hahn, E.K.2    Grizas, A.P.3
  • 12
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical method for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 67049119848 scopus 로고    scopus 로고
    • Actigraphy in the assessment of insomnia: a quantitative approach
    • Natale V, Plazzi G, Martoni M. Actigraphy in the assessment of insomnia: a quantitative approach. Sleep 2009; 32: 767-71.
    • (2009) Sleep , vol.32 , pp. 767-771
    • Natale, V.1    Plazzi, G.2    Martoni, M.3
  • 14
    • 33646950433 scopus 로고    scopus 로고
    • Actigraphic validation with insomnia
    • Lichstein KL, Stone KC, Donaldson J etal. Actigraphic validation with insomnia. Sleep 2006; 29: 232-9.
    • (2006) Sleep , vol.29 , pp. 232-239
    • Lichstein, K.L.1    Stone, K.C.2    Donaldson, J.3
  • 15
    • 84856978869 scopus 로고    scopus 로고
    • Direct comparison of two new actigraphs and polysomnography in children and adolescent
    • Meltzer LJ, Walsh CM, Traylor J, Westin AML. Direct comparison of two new actigraphs and polysomnography in children and adolescent. Sleep 2012; 35 (1): 159-66.
    • (2012) Sleep , vol.35 , Issue.1 , pp. 159-166
    • Meltzer, L.J.1    Walsh, C.M.2    Traylor, J.3    Westin, A.M.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.