메뉴 건너뛰기




Volumn 23, Issue 9, 2012, Pages 2127-2139

Influence of sodium hypochlorite treatment of electropolished and magnetoelectropolished nitinol surfaces on adhesion and proliferation of MC3T3 pre-osteoblast cells

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROPOLISHED; IN-VITRO; OSTEOBLAST CELLS; OXIDE LAYER; OXYGEN CONTENT; SODIUM HYPOCHLORITES; XPS ANALYSIS;

EID: 84867096214     PISSN: 09574530     EISSN: 15734838     Source Type: Journal    
DOI: 10.1007/s10856-012-4696-1     Document Type: Article
Times cited : (26)

References (38)
  • 1
    • 0030340747 scopus 로고    scopus 로고
    • On the nature of the biocompatibility and on medical applications of niti shape memory and superelastic alloys
    • Shabalovskaya SA. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. Biomed Mater Eng. 1996;6:267-89.
    • (1996) Biomed Mater Eng , vol.6 , pp. 267-268
    • Shabalovskaya, S.A.1
  • 2
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopedic implants
    • Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopedic implants. J Bone Jt Surg. 2011;83(3):428-36.
    • (2011) J Bone Jt Surg , vol.83 , Issue.3 , pp. 428-423
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 3
    • 43949164704 scopus 로고
    • Principles underlying the role of adsorbed plasmaproteins in blood interaction with foreign materials
    • Horbett TA. Principles underlying the role of adsorbed plasmaproteins in blood interaction with foreign materials. Cardiovasc Pathol. 1993;2(3):137-48.
    • (1993) Cardiovasc Pathol , vol.2 , Issue.3 , pp. 137-134
    • Horbett, T.A.1
  • 4
    • 0023637601 scopus 로고
    • New perspectives in cell adhesion: RGD and integrins
    • Ruoslahti E, Pierschbacher MD. New perspectives in cell adhesion: RGD and integrins. Science. 1987;238:491-7. (Pubitemid 17147032)
    • (1987) Science , vol.238 , Issue.4826 , pp. 491-497
    • Ruoslahti, E.1    Pierschbacher, M.D.2
  • 5
    • 84861626491 scopus 로고    scopus 로고
    • Review article: Biomedical applications of shape memory alloys. Hindawi publishing corporation
    • Article ID 501483
    • Petrini L, Migiavacca F. Review article: biomedical applications of shape memory alloys. Hindawi Publishing Corporation, J Metall. 2011. pp. 15. Article ID 501483.
    • (2011) J Metall , pp. 15
    • Petrini, L.1    Migiavacca, F.2
  • 6
    • 80052621457 scopus 로고    scopus 로고
    • Enhanced biocompatibility of niti (nitinol) via surface treatment and alloying
    • Florida International University, Miami, Paper 177
    • Haider W. Enhanced biocompatibility of NiTi (Nitinol) via surface treatment and alloying. Electronic Theses and Dissertations. 2010. Florida International University, Miami, Paper 177.
    • (2010) Electronic Theses and Dissertations
    • Haider, W.1
  • 9
    • 79952193311 scopus 로고    scopus 로고
    • Bone cell-materials interaction and ni ion release of anodized equiatomic niti alloy
    • Bernard SA, Balla VK, Devies NM, Bose S, Bandyopadhyay A. Bone cell-materials interaction and Ni ion release of anodized equiatomic NiTi alloy. Acta Biomater. 2011;7:1902-12.
    • (2011) Acta Biomater , vol.7 , pp. 12
    • Bernard, S.A.1    Balla, V.K.2    Devies, N.M.3    Bose, S.4    Bandyopadhyay, A.5
  • 10
    • 33749588841 scopus 로고    scopus 로고
    • 4
    • DOI 10.1016/j.electacta.2006.07.030, PII S001346860600764X
    • Fushimi K, Startmann M, Hassel A. Electropolishing of NiTi shape memory alloys in methanolic H2SO4. Electrochim Acta. 2006;52:1290-5. (Pubitemid 44540289)
    • (2006) Electrochimica Acta , vol.52 , Issue.3 , pp. 1290-1295
    • Fushimi, K.1    Stratmann, M.2    Hassel, A.W.3
  • 11
    • 54249109051 scopus 로고    scopus 로고
    • Nitinol surface finishing by magnetoelectropolishing
    • Rokicki R, Hryniewicz T. Nitinol surface finishing by magnetoelectropolishing. Trans Inst Metal Finish. 2008;86(5):280-5.
    • (2008) Trans Inst Metal Finish , vol.86 , Issue.5 , pp. 280-285
    • Rokicki, R.1    Hryniewicz, T.2
  • 12
    • 58749096687 scopus 로고    scopus 로고
    • Corrosion and surface characterization of titanium biomaterial after magnetoelectropolishing
    • Hryniewicz T, Rokicki R, Rokosz K. Corrosion and surface characterization of titanium biomaterial after magnetoelectropolishing. Surf Coat Technol. 2009;203(10-11):1508-15.
    • (2009) Surf Coat Technol , vol.203 , Issue.10-11 , pp. 1508-1501
    • Hryniewicz, T.1    Rokicki, R.2    Rokosz, K.3
  • 15
    • 35148823667 scopus 로고    scopus 로고
    • Study of the formation of self-Assembled monolayers on nitinol
    • Quinones R, Gawalt ES. Study of the formation of self-Assembled monolayers on nitinol. Langmuir. 2007;23(20):10123-30.
    • (2007) Langmuir , vol.23 , Issue.20 , pp. 10123-10123
    • Quinones, R.1    Gawalt, E.S.2
  • 16
    • 79953686203 scopus 로고    scopus 로고
    • The underlying biological mechanisms of biocompatibility differences between bare and tin-coated niti alloys
    • (12pp
    • Lifeng Z, Yan H, Dayun Y, Xiaoying L, Tingfei X, Deyuan Z, Ying H, Jinfeng Y. The underlying biological mechanisms of biocompatibility differences between bare and TiN-coated NiTi alloys. Biomed Mater. 2011;6:0250012 (12pp).
    • (2011) Biomed Mater , vol.6 , pp. 0250012
    • Lifeng, Z.1    Yan, H.2    Dayun, Y.3    Xiaoying, L.4    Tingfei, X.5    Deyuan, Z.6    Ying, H.7    Jinfeng, Y.8
  • 17
    • 53349141040 scopus 로고    scopus 로고
    • Silicon carbide coating of nitinol stents to increase antitrombogenic properties and reduce nickel release
    • Schmehl JM, Harder C, Wendel HP, Claussen CD, Tepe G. Silicon carbide coating of nitinol stents to increase antitrombogenic properties and reduce nickel release. Cardiovasc Revasc Med. 2008;9(4):255-62.
    • (2008) Cardiovasc Revasc Med , vol.9 , Issue.4 , pp. 255-256
    • Schmehl, J.M.1    Harder, C.2    Wendel, H.P.3    Claussen, C.D.4    Tepe, G.5
  • 18
    • 79955837421 scopus 로고    scopus 로고
    • Polymeric coating of surface modified nitinol stent with possnanocomposite polymer
    • Bakhshi R, Darbyshire A, Evans JE, You Z, Lu J, Seifalian AM. Polymeric coating of surface modified nitinol stent with POSSnanocomposite polymer. Colloids Surf B. 2011;86(1):93-105.
    • (2011) Colloids Surf B , vol.86 , Issue.1 , pp. 93-91
    • Bakhshi, R.1    Darbyshire, A.2    Evans, J.E.3    You, Z.4    Lu, J.5    Seifalian, A.M.6
  • 19
    • 57749089771 scopus 로고    scopus 로고
    • Electropolishing of niti for improving biocompatibility
    • Wu W, Liu X, Han H, Yang D, Lu S. Electropolishing of NiTi for improving biocompatibility. J Mater Sci Technol. 2008;24(6): 926-30.
    • (2008) J Mater Sci Technol , vol.24 , Issue.6 , pp. 926-923
    • Wu, W.1    Liu, X.2    Han, H.3    Yang, D.4    Lu, S.5
  • 21
    • 77952874339 scopus 로고    scopus 로고
    • Detecting nitinol surface inclusions
    • Rokicki R. Detecting nitinol surface inclusions. Mater Device Diagn Ind. 2010;32(2):44-8.
    • (2010) Mater Device Diagn Ind , vol.32 , Issue.2 , pp. 44-48
    • Rokicki, R.1
  • 22
    • 84874208354 scopus 로고    scopus 로고
    • Nitinol Devices & Components Inc
    • Nitinol Devices & Components Inc. http://www.qmed.com/supplier/ nitinol-devices-components.
  • 24
    • 0028043278 scopus 로고
    • Establishment of nickel-specific T cell lines from patients with allergic contact dermatitis: Comparison of different protocols
    • DOI 10.1006/clin.1994.1180
    • Bour H, Nicolas JF, Garrigue JL, Demiden A, Schmitt D. Establishment of nickel specific T cell lines from patients with allergic contact dermatitis: comparison of different protocols. Clin Immunol Immunopatol. 1994;73:142-5. (Pubitemid 24310790)
    • (1994) Clinical Immunology and Immunopathology , vol.73 , Issue.1 , pp. 142-145
    • Bour, H.1    Nicolas, J.F.2    Garrigue, J.L.3    Demidem, A.4    Schmitt, D.5
  • 27
    • 77950516891 scopus 로고    scopus 로고
    • On the wear inspection and endurance recovery of nitinol endodontic files
    • Hryniewicz T, Rokosz K. On the wear inspection and endurance recovery of nitinol endodontic files. PAK (Measurement Automation and Monitoring). 2009;55(4):247-50.
    • (2009) PAK (Measurement Automation and Monitoring , vol.55 , Issue.4 , pp. 247-245
    • Hryniewicz, T.1    Rokosz, K.2
  • 28
    • 85027919152 scopus 로고    scopus 로고
    • Assessment of corrosion resistance and metal ion leaching of nitinol alloys
    • Haider W, Munroe N. Assessment of corrosion resistance and metal ion leaching of nitinol alloys. J Mater Eng Perform. 2011;20(4):812-5.
    • (2011) J Mater Eng Perform , vol.20 , Issue.4 , pp. 812-815
    • Haider, W.1    Munroe, N.2
  • 30
    • 0025130329 scopus 로고
    • The passive oxide film on electropolished titanium
    • Rokicki R. The passive oxide film on electropolished titanium. Metal Finish. 1990;88(2):69-70.
    • (1990) Metal Finish , vol.88 , Issue.2 , pp. 69-67
    • Rokicki, R.1
  • 31
    • 0032487118 scopus 로고    scopus 로고
    • Relative importance of surface wettabillity and charged functional groups on nih 3t3 fibroblast attachment, spreading and cytoskeletal organization
    • Webb K, Hlady V, Tresco PA. Relative importance of surface wettabillity and charged functional groups on NIH 3T3 fibroblast attachment, spreading and cytoskeletal organization. J Biomed Mater Res. 1998;41:422-30.
    • (1998) J Biomed Mater Res , vol.41 , pp. 422-423
    • Webb, K.1    Hlady, V.2    Tresco, P.A.3
  • 33
    • 83455198257 scopus 로고    scopus 로고
    • Review: Radiation and ethylene oxide terminal sterilization experiences with drug eluting stent products
    • Lambert BJ, Mendelson TA, Craven MD. Review: radiation and ethylene oxide terminal sterilization experiences with drug eluting stent products. AAPS Pharm Sci Tech. 2011;12(4):1116-26.
    • (2011) AAPS Pharm Sci Tech , vol.12 , Issue.4 , pp. 1116-1112
    • Lambert, B.J.1    Mendelson, T.A.2    Craven, M.D.3
  • 34
    • 41549097188 scopus 로고    scopus 로고
    • Review: Critical overview of nitinol surfaces and their modifications for medical applications
    • Shabalovskaya SA, Anderegg J, van Humbeeck J. Review: critical overview of nitinol surfaces and their modifications for medical applications. Acta Biomater. 2008;4:447-67.
    • (2008) Acta Biomater , vol.4 , pp. 447-446
    • Shabalovskaya, S.A.1    Anderegg, J.2    Van Humbeeck, J.3
  • 35
    • 0036179018 scopus 로고    scopus 로고
    • Surface, corrosion and biocompatibility aspects of nitinol as an implant material
    • Shabalovskaya SA. Surface, corrosion and biocompatibility aspects of nitinol as an implant material. Biomed Mater Eng. 2002;12(1):69-109.
    • (2002) Biomed Mater Eng , vol.12 , Issue.1 , pp. 69-61
    • Shabalovskaya, S.A.1
  • 36
    • 0033990205 scopus 로고    scopus 로고
    • Effect of sterilization processes on niti alloy: Surface characterization
    • Thierry B, Tabrizian M, Savadogo O, Yahia L. Effect of sterilization processes on NiTi alloy: surface characterization. J Biomed Mater Res. 2000;49:88-98.
    • (2000) J Biomed Mater Res , vol.49 , pp. 88-89
    • Thierry, B.1    Tabrizian, M.2    Savadogo, O.3    Yahia, L.4
  • 38
    • 77955430392 scopus 로고    scopus 로고
    • Electropolishing enhances the resistance of nickel-Titanium rotary files to corrosion fatigue failure in hypochlorite
    • Praisarnti C, Chang JWW, Cheung GSP. Electropolishing enhances the resistance of nickel-Titanium rotary files to corrosion fatigue failure in hypochlorite. J Endod. 2010;36:264-7.
    • (2010) J Endod , vol.36 , pp. 264-267
    • Praisarnti, C.1    Chang, J.W.W.2    Cheung, G.S.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.