메뉴 건너뛰기




Volumn 13, Issue 6, 2012, Pages 971-977

Experimental studies on the heating performance of the PTC heater and heat pump combined system in fuel cells and electric vehicles

Author keywords

COP; Dynamic characteristics; Electric vehicles; Heat pump; Optimal operation; PTC Heater; Steady state; Warm up

Indexed keywords

COP; DYNAMIC CHARACTERISTICS; HEAT PUMPS; OPTIMAL OPERATION; PTC HEATER; STEADY STATE; WARM UP;

EID: 84867072256     PISSN: 12299138     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12239-012-0099-z     Document Type: Article
Times cited : (60)

References (6)
  • 1
    • 7544236220 scopus 로고    scopus 로고
    • Heat pump supplemental heating system for motor vehicles
    • Antonijevic, D. and Heckt, R. (2004). Heat pump supplemental heating system for motor vehicles. J. Automobile Engineering, 218, 1111-1115.
    • (2004) J. Automobile Engineering , vol.218 , pp. 1111-1115
    • Antonijevic, D.1    Heckt, R.2
  • 4
    • 0037355534 scopus 로고    scopus 로고
    • An experimental analysis of automotive air conditioning system
    • Horuz, I. and Kaynakli, O. (2003). An experimental analysis of automotive air conditioning system. Int. Comm. Heat Mass Transfer30, 2, 273-284.
    • (2003) Int. Comm. Heat Mass Transfer , vol.30 , Issue.2 , pp. 273-284
    • Horuz, I.1    Kaynakli, O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.