메뉴 건너뛰기




Volumn 173, Issue , 2012, Pages 704-709

Myoglobin immobilized on LaF 3 doped CeO 2 and ionic liquid composite film for nitrite biosensor

Author keywords

Biosensor; Ionic liquid; LaF 3 DP CeO 2; Myoglobin; Nitrite

Indexed keywords

AMPEROMETRIC RESPONSE; BIOSENSOR DESIGN; CIRCULAR DICHROISM SPECTRA; DETECTION LIMITS; DOPED CEO; ELECTROCHEMICAL DETERMINATION; ELECTRODE SURFACES; ELECTRON TRANSFER; FAST RESPONSE TIME; FOURIER TRANSFORM INFRARED SPECTRA; GOOD STABILITY; HIGH AFFINITY; IONIC LIQUID COMPOSITES; LAF 3-DP-CEO 2; LINEAR RANGE; MICHAELIS-MENTEN CONSTANT; MICROENVIRONMENTS; MYOGLOBIN; NATIVE STATE; NITRITE; POTENTIAL APPLICATIONS; PROTEIN IMMOBILIZATION; SECONDARY STRUCTURES; ULTRAVIOLET-VISIBLE SPECTRA;

EID: 84867053331     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.07.073     Document Type: Article
Times cited : (29)

References (33)
  • 1
    • 0014930605 scopus 로고
    • Nitrosamines as environmental carcinogens
    • W. Lijinsky, and S.S. Epstein Nitrosamines as environmental carcinogens Nature 225 1970 21 23
    • (1970) Nature , vol.225 , pp. 21-23
    • Lijinsky, W.1    Epstein, S.S.2
  • 2
    • 0029071838 scopus 로고
    • Role of N-nitroso compounds (NOC) and N-nitrosation in etiology of gastric, esophageal, nasopharyngeal and bladder cancer and contribution to cancer of known exposures to NOC
    • S.S. Mirvish Role of N-nitroso compounds (NOC) and N-nitrosation in etiology of gastric, esophageal, nasopharyngeal and bladder cancer and contribution to cancer of known exposures to NOC Cancer Letters 93 1995 17 48
    • (1995) Cancer Letters , vol.93 , pp. 17-48
    • Mirvish, S.S.1
  • 3
    • 34547307365 scopus 로고    scopus 로고
    • Flow-injection spectrophotometry of nitrites based on the diazotization reactions of azine dyes
    • V. Kuznetsov, and S. Zemyatova Flow-injection spectrophotometry of nitrites based on the diazotization reactions of azine dyes Journal of Analytical Chemistry 62 2007 637 644
    • (2007) Journal of Analytical Chemistry , vol.62 , pp. 637-644
    • Kuznetsov, V.1    Zemyatova, S.2
  • 4
    • 33748067307 scopus 로고    scopus 로고
    • A new tool for inorganic nitrogen speciation study: Simultaneously determination of ammonium ion, nitrite and nitrate by ion chromatography with post-column ammonium derivatization by Nessler reagent and diode-array detection in rain water samples
    • P. Niedzielski, I. Kurzyca, and J. Siepak A new tool for inorganic nitrogen speciation study: simultaneously determination of ammonium ion, nitrite and nitrate by ion chromatography with post-column ammonium derivatization by Nessler reagent and diode-array detection in rain water samples Analytica Chimica Acta 577 2006 220 224
    • (2006) Analytica Chimica Acta , vol.577 , pp. 220-224
    • Niedzielski, P.1    Kurzyca, I.2    Siepak, J.3
  • 5
    • 34247222132 scopus 로고    scopus 로고
    • Direct electrochemistry of hemoglobin and glucose oxidase in electrodeposited sol-gel silica thin films on glassy carbon
    • O. Nadzhafova, M. Etienne, and A. Walcarius Direct electrochemistry of hemoglobin and glucose oxidase in electrodeposited sol-gel silica thin films on glassy carbon Electrochemistry Communications 9 2007 1189 1195
    • (2007) Electrochemistry Communications , vol.9 , pp. 1189-1195
    • Nadzhafova, O.1    Etienne, M.2    Walcarius, A.3
  • 6
    • 34547563367 scopus 로고    scopus 로고
    • Manganese dioxide graphite composite electrodes formed via a low temperature method: Detection of hydrogen peroxide, ascorbic acid and nitrite
    • B. Sljukic, and R. Compton Manganese dioxide graphite composite electrodes formed via a low temperature method: detection of hydrogen peroxide, ascorbic acid and nitrite Electroanalysis 19 2007 1275 1280
    • (2007) Electroanalysis , vol.19 , pp. 1275-1280
    • Sljukic, B.1    Compton, R.2
  • 7
    • 0037084088 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of nitrite on a vitreous carbon electrode modified with cobalt phthalocyanine
    • C.A. Caro, F. Bedioui, and J.H. Zagal Electrocatalytic oxidation of nitrite on a vitreous carbon electrode modified with cobalt phthalocyanine Electrochimica Acta 47 2002 1489 1494
    • (2002) Electrochimica Acta , vol.47 , pp. 1489-1494
    • Caro, C.A.1    Bedioui, F.2    Zagal, J.H.3
  • 8
    • 33644780961 scopus 로고    scopus 로고
    • Fabrication of electroactive layer-by-layer films of myoglobin with gold nanoparticles of different sizes
    • H. Zhang, H.Y. Lu, and N.F. Hu Fabrication of electroactive layer-by-layer films of myoglobin with gold nanoparticles of different sizes Journal of Physical Chemistry B 110 2006 2171 2179
    • (2006) Journal of Physical Chemistry B , vol.110 , pp. 2171-2179
    • Zhang, H.1    Lu, H.Y.2    Hu, N.F.3
  • 10
    • 67349263528 scopus 로고    scopus 로고
    • Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film
    • A.A. Ansari, P.R. Solanki, and B.D. Malhotra Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film Journal of Biotechnology 142 2009 179 184
    • (2009) Journal of Biotechnology , vol.142 , pp. 179-184
    • Ansari, A.A.1    Solanki, P.R.2    Malhotra, B.D.3
  • 13
    • 80052806518 scopus 로고    scopus 로고
    • Synthesis of nanosized gadolinium doped ceria solid soution by high energy ball milling
    • Z. Khakpour, A.A. Youzbashi, A. Maghsoudipour, and K. Ahmadi Synthesis of nanosized gadolinium doped ceria solid soution by high energy ball milling Powder Technology 214 2011 117 121
    • (2011) Powder Technology , vol.214 , pp. 117-121
    • Khakpour, Z.1    Youzbashi, A.A.2    Maghsoudipour, A.3    Ahmadi, K.4
  • 14
    • 3242776205 scopus 로고    scopus 로고
    • 3+ co-doped ceria based electrolytes for intermediate temperature solid oxide fuel cells
    • 3+ co-doped ceria based electrolytes for intermediate temperature solid oxide fuel cells Electrochemistry Communications 6 2004 743 746
    • (2004) Electrochemistry Communications , vol.6 , pp. 743-746
    • Wang, F.Y.1    Chen, S.Y.2    Cheng, S.F.3
  • 16
    • 0000337013 scopus 로고
    • Fourier self-deconvolution: A method for resolving intrinsically overlapped bands
    • J.K. Kauppinen, D.J. Moffat, H.H. Mantsch, and D.G. Cameron Fourier self-deconvolution: a method for resolving intrinsically overlapped bands Applied Spectroscopy 35 1981 271 276
    • (1981) Applied Spectroscopy , vol.35 , pp. 271-276
    • Kauppinen, J.K.1    Moffat, D.J.2    Mantsch, H.H.3    Cameron, D.G.4
  • 19
    • 0035861311 scopus 로고    scopus 로고
    • Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid cysteamine-modified gold electrode
    • H.Y. Gu, A.M. Yu, and H.Y. Chen Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid cysteamine-modified gold electrode Journal of Electroanalytical Chemistry 516 2001 119 126
    • (2001) Journal of Electroanalytical Chemistry , vol.516 , pp. 119-126
    • Gu, H.Y.1    Yu, A.M.2    Chen, H.Y.3
  • 20
    • 77952743653 scopus 로고    scopus 로고
    • Hydrogen peroxide biosensor based on a myoglobin/hydrophilic room temperature ionic liquid film
    • A. Safavi, and F. Fariami Hydrogen peroxide biosensor based on a myoglobin/hydrophilic room temperature ionic liquid film Analytical Biochemistry 402 2010 20 25
    • (2010) Analytical Biochemistry , vol.402 , pp. 20-25
    • Safavi, A.1    Fariami, F.2
  • 22
    • 0033663518 scopus 로고    scopus 로고
    • Direct electrochemistry of hemoglobin in polyacrylamide hydrogel films on pyrolytic graphite electrodes
    • H. Sun, N.F. Hu, and H.Y. Ma Direct electrochemistry of hemoglobin in polyacrylamide hydrogel films on pyrolytic graphite electrodes Electroanalysis 12 2000 1064 1070
    • (2000) Electroanalysis , vol.12 , pp. 1064-1070
    • Sun, H.1    Hu, N.F.2    Ma, H.Y.3
  • 23
    • 0000739645 scopus 로고
    • Enhanced electron-transfer for myoglobin in surfactant films on electrodes
    • J.F. Rusling, and A.E.F. Nassar Enhanced electron-transfer for myoglobin in surfactant films on electrodes Journal of the American Chemical Society 115 1993 11891 11897
    • (1993) Journal of the American Chemical Society , vol.115 , pp. 11891-11897
    • Rusling, J.F.1    Nassar, A.E.F.2
  • 24
    • 75349096999 scopus 로고    scopus 로고
    • An electrochemical biosensor based on nafion-ionic liquid and a myoglobin-modified carbon paste electrode
    • X.Q. Li, R.J. Zhao, Y. Wang, X.Y. Sun, W. Sun, C.Z. Zhao, and K. Jiao An electrochemical biosensor based on nafion-ionic liquid and a myoglobin-modified carbon paste electrode Electrochimica Acta 55 2010 2173 2178
    • (2010) Electrochimica Acta , vol.55 , pp. 2173-2178
    • Li, X.Q.1    Zhao, R.J.2    Wang, Y.3    Sun, X.Y.4    Sun, W.5    Zhao, C.Z.6    Jiao, K.7
  • 25
    • 78649327667 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalysis of myoglobin immobilized on zirconia/multi-walled carbon nanotube nanocomposite
    • R.P. Liang, M.Q. Deng, S.G. Cui, H. Chen, and J.D. Qiu Direct electrochemistry and electrocatalysis of myoglobin immobilized on zirconia/multi-walled carbon nanotube nanocomposite Materials Research Bulletin 45 2010 1855 1860
    • (2010) Materials Research Bulletin , vol.45 , pp. 1855-1860
    • Liang, R.P.1    Deng, M.Q.2    Cui, S.G.3    Chen, H.4    Qiu, J.D.5
  • 26
    • 36048970504 scopus 로고    scopus 로고
    • Assembly of quantum dots-mesoporous silicate hybrid material for protein immobilization and direct electrochemistry
    • Q. Zhang, L. Zhang, B. Liu, X.B. Lu, and J.H. Li Assembly of quantum dots-mesoporous silicate hybrid material for protein immobilization and direct electrochemistry Biosensors and Bioelectronics 23 2007 695 700
    • (2007) Biosensors and Bioelectronics , vol.23 , pp. 695-700
    • Zhang, Q.1    Zhang, L.2    Liu, B.3    Lu, X.B.4    Li, J.H.5
  • 27
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems Journal of Electroanalytical Chemistry 101 1979 19 28
    • (1979) Journal of Electroanalytical Chemistry , vol.101 , pp. 19-28
    • Laviron, E.1
  • 28
    • 0042890314 scopus 로고    scopus 로고
    • Direct electrochemistry and nitric oxide interaction of heme proteins adsorbed on nanocrystalline tin oxide electrodes
    • E. Topoglidis, Y. Astuti, F. Duriaux, M. Grätzel, and J.R. Durrant Direct electrochemistry and nitric oxide interaction of heme proteins adsorbed on nanocrystalline tin oxide electrodes Langmuir 19 2003 6894 6900
    • (2003) Langmuir , vol.19 , pp. 6894-6900
    • Topoglidis, E.1    Astuti, Y.2    Duriaux, F.3    Grätzel, M.4    Durrant, J.R.5
  • 29
    • 84867038930 scopus 로고    scopus 로고
    • Direct electrochemistry of hemoglobin immobilized on electrode modified by ceria
    • Y. Li, Y.F. Gao, Y.C. Liu, Y. Zhou, and J.R. Liu Direct electrochemistry of hemoglobin immobilized on electrode modified by ceria Acta Chimica Sinica 68 2010 1161 1166
    • (2010) Acta Chimica Sinica , vol.68 , pp. 1161-1166
    • Li, Y.1    Gao, Y.F.2    Liu, Y.C.3    Zhou, Y.4    Liu, J.R.5
  • 30
    • 77953135820 scopus 로고    scopus 로고
    • A biosensor based on cytochrome c immobilization on a poly-3-methylthiophene/multi-walled carbon nanotubes hybrid-modified electrode. Application to the electrochemical determination of nitrite
    • M. Eguílaz, L. Agüí, P. Yáñez- Sedeño, and J.M. Pingarrón A biosensor based on cytochrome c immobilization on a poly-3-methylthiophene/multi-walled carbon nanotubes hybrid-modified electrode. Application to the electrochemical determination of nitrite Journal of Electroanalytical Chemistry 644 2010 30 35
    • (2010) Journal of Electroanalytical Chemistry , vol.644 , pp. 30-35
    • Eguílaz, M.1    Agüí, L.2    Yáñez-Sedeño, P.3    Pingarrón, J.M.4
  • 31
    • 46149127094 scopus 로고    scopus 로고
    • Porous nanosheet-based ZnO microspheres for the construction of direct electrochemical biosensors
    • X.B. Lu, H.J. Zhang, Y.W. Ni, Q. Zhang, and J.P. Chen Porous nanosheet-based ZnO microspheres for the construction of direct electrochemical biosensors Biosensors and Bioelectronics 24 2008 93 98
    • (2008) Biosensors and Bioelectronics , vol.24 , pp. 93-98
    • Lu, X.B.1    Zhang, H.J.2    Ni, Y.W.3    Zhang, Q.4    Chen, J.P.5
  • 32
    • 65349101245 scopus 로고    scopus 로고
    • Direct electrochemistry of myoglobin in a nafion-ionic liquid composite film modified carbon ionic liquid electrode
    • W. Sun, X.Q. Li, and K. Jiao Direct electrochemistry of myoglobin in a nafion-ionic liquid composite film modified carbon ionic liquid electrode Electroanalysis 21 2009 959 964
    • (2009) Electroanalysis , vol.21 , pp. 959-964
    • Sun, W.1    Li, X.Q.2    Jiao, K.3
  • 33
    • 67651087390 scopus 로고    scopus 로고
    • Electrodeposition of Co nanoparticles on the carbon ionic liquid electrode as a platform for myoglobin electrochemical biosensor
    • W. Sun, X.Q. Li, P. Qin, and K. Jiao Electrodeposition of Co nanoparticles on the carbon ionic liquid electrode as a platform for myoglobin electrochemical biosensor Journal of Physical Chemistry C 113 2009 11294 11300
    • (2009) Journal of Physical Chemistry C , vol.113 , pp. 11294-11300
    • Sun, W.1    Li, X.Q.2    Qin, P.3    Jiao, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.