메뉴 건너뛰기




Volumn 6, Issue 3, 2012, Pages 206-212

Correlation between blood glucose and hematocrit: A new estimation methodology

Author keywords

Anemic; Biosensor; Biosignal; Data mining; Hematocrit; Hematocrit estimation

Indexed keywords

BIOSENSORS; BLOOD; ESTIMATION; GLUCOSE; MATRIX ALGEBRA;

EID: 84866982231     PISSN: 19760280     EISSN: 20927843     Source Type: Journal    
DOI: 10.1007/s13206-012-6302-5     Document Type: Article
Times cited : (5)

References (23)
  • 1
    • 49049113124 scopus 로고    scopus 로고
    • Electrochemical glucose sensors and their applications in diabetes management
    • Heller, A. & Feldman, B. Electrochemical glucose sensors and their applications in diabetes management. Chem. Rev. 108, 2482-2505 (2008).
    • (2008) Chem. Rev , vol.108 , pp. 2482-2505
    • Heller, A.1    Feldman, B.2
  • 2
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • Wang, J. Electrochemical glucose biosensors. Chem. Rev. 108, 814-825 (2008).
    • (2008) Chem. Rev , vol.108 , pp. 814-825
    • Wang, J.1
  • 3
    • 77954855173 scopus 로고    scopus 로고
    • Electrochemistry in diabetes management
    • Heller, A. & Feldman, B. Electrochemistry in diabetes management. Account Chem. Res. 43, 963-973 (2010).
    • (2010) Account Chem. Res , vol.43 , pp. 963-973
    • Heller, A.1    Feldman, B.2
  • 4
    • 44249100012 scopus 로고    scopus 로고
    • The technology behind glucose meters: test strips
    • Hones, J., Muller, P. & Surridge, N. The technology behind glucose meters: test strips. Diabetes Technol. Ther. 10, 10-26 (2008).
    • (2008) Diabetes Technol. Ther , vol.10 , pp. 10-26
    • Hones, J.1    Muller, P.2    Surridge, N.3
  • 5
    • 0000775452 scopus 로고
    • Surface-modified electrochemical detector for liquid chromatography
    • Sittampalam, G. & Wilson, G. S. Surface-modified electrochemical detector for liquid chromatography. Anal. Chem. 55, 1608-1610 (1983).
    • (1983) Anal. Chem , vol.55 , pp. 1608-1610
    • Sittampalam, G.1    Wilson, G.S.2
  • 6
    • 0021494858 scopus 로고
    • Ion-exchange selectivity of nafion® films on electrode surfaces
    • Szentirmay, M. N. & Martin, C. R. Ion-exchange selectivity of nafion® films on electrode surfaces. Anal. Chem. 56, 1898-1902 (1984).
    • (1984) Anal. Chem , vol.56 , pp. 1898-1902
    • Szentirmay, M.N.1    Martin, C.R.2
  • 7
    • 0024095481 scopus 로고
    • Characterization of perpfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • Harrison, D. J., Turner, R. F. B. & Baltes, H. P. Characterization of perpfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. Anal. Chem. 60, 2002-2007 (1988).
    • (1988) Anal. Chem , vol.60 , pp. 2002-2007
    • Harrison, D.J.1    Turner, R.F.B.2    Baltes, H.P.3
  • 8
    • 0024817159 scopus 로고
    • Electrochemical behaviour of a lipid modified enzyme electrode
    • Amine, A., Kauffmann, J. M., Patriarche, G. J. & Guilbault, G. G. Electrochemical behaviour of a lipid modified enzyme electrode. Anal. Lett. 22, 2403-2411 (1989).
    • (1989) Anal. Lett , vol.22 , pp. 2403-2411
    • Amine, A.1    Kauffmann, J.M.2    Patriarche, G.J.3    Guilbault, G.G.4
  • 9
    • 0035816469 scopus 로고    scopus 로고
    • Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
    • Cui, G. et al. Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip. Talanta54, 1105-1111 (2001).
    • (2001) Talanta , vol.54 , pp. 1105-1111
    • Cui, G.1
  • 10
    • 0025306487 scopus 로고
    • Carbon paste-tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing systems
    • Gunasingham, H. & Tan, C. H. Carbon paste-tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing systems. Analyst115, 35-39 (1990).
    • (1990) Analyst , vol.115 , pp. 35-39
    • Gunasingham, H.1    Tan, C.H.2
  • 11
    • 0026089406 scopus 로고
    • Are blood glucose reagent strips are reliable in renal failure
    • Clark, J. D. A., Goldberg, L., Jones, K. & Hartog, M. Are blood glucose reagent strips are reliable in renal failure. Diabetic Med. 8, 168-171 (1991).
    • (1991) Diabetic Med , vol.8 , pp. 168-171
    • Clark, J.D.A.1    Goldberg, L.2    Jones, K.3    Hartog, M.4
  • 12
    • 59549102739 scopus 로고    scopus 로고
    • Non-linear estimation methods for hematocrit density based on changing pattern of transduced anodic current curve
    • Huynh, H. T., Kim, J. J. & Won, Y. Non-linear estimation methods for hematocrit density based on changing pattern of transduced anodic current curve. Wseas. Trans. Inf. Sci. App. 5, 1541-1550 (2008).
    • (2008) Wseas. Trans. Inf. Sci. App , vol.5 , pp. 1541-1550
    • Huynh, H.T.1    Kim, J.J.2    Won, Y.3
  • 13
    • 35649022674 scopus 로고    scopus 로고
    • Reduction of the interferences of biochemical and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips
    • Lin, Y. H., Shen, T. Y. & Chang, A. Reduction of the interferences of biochemical and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips. Anal. Bioanal. Chem. 389, 1623-1631 (2007).
    • (2007) Anal. Bioanal. Chem , vol.389 , pp. 1623-1631
    • Lin, Y.H.1    Shen, T.Y.2    Chang, A.3
  • 14
    • 84857431968 scopus 로고    scopus 로고
    • Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices
    • Musholt, P. B. et al. Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices. J. Diabetes Sci. Technnol. 5, 1167-1175 (2011).
    • (2011) J. Diabetes Sci. Technnol , vol.5 , pp. 1167-1175
    • Musholt, P.B.1
  • 15
    • 0033966742 scopus 로고    scopus 로고
    • Point of care glucose testing: effects of critical variables, influence of reference instruments, and a modular glucose meter design
    • Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H. & Kost, G. J. Point of care glucose testing: effects of critical variables, influence of reference instruments, and a modular glucose meter design. Arch. Pathol. Lab. Med. 124, 257-266 (2000).
    • (2000) Arch. Pathol. Lab. Med , vol.124 , pp. 257-266
    • Louie, R.F.1    Tang, Z.2    Sutton, D.V.3    Lee, J.H.4    Kost, G.J.5
  • 16
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing
    • Tang, Z., Lee, J. H., Louie, R. F. & Kost, G. J. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch. Pathol. Lab. Med. 124, 1135-1140 (2000).
    • (2000) Arch. Pathol. Lab. Med , vol.124 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3    Kost, G.J.4
  • 17
    • 0027214655 scopus 로고
    • The effect of variations in hematocrit, mean cell volume and red blood count on reagent strip tests for glucose
    • Kilpatrick, E. S., Rumley, A. G. & Myin, H. The effect of variations in hematocrit, mean cell volume and red blood count on reagent strip tests for glucose. Ann. Clin. Biochem. 30, 485-487 (1993).
    • (1993) Ann. Clin. Biochem , vol.30 , pp. 485-487
    • Kilpatrick, E.S.1    Rumley, A.G.2    Myin, H.3
  • 19
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: a critical review
    • Foster, K. R. & Schwan, H. P. Dielectric properties of tissues and biological materials: a critical review. Crit. Rev. Biomed. Eng. 17, 25-104 (1989).
    • (1989) Crit. Rev. Biomed. Eng , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 20
    • 77953494285 scopus 로고    scopus 로고
    • Glucose biosensors: An overview of use in clinical practice
    • Yoo, E. H. & Lee, S. Y. Glucose biosensors: An overview of use in clinical practice. Sensors10, 4558-4576 (2010).
    • (2010) Sensors , vol.10 , pp. 4558-4576
    • Yoo, E.H.1    Lee, S.Y.2
  • 22
    • 0027586990 scopus 로고
    • Novel electrochemical device for the detection of cholesterol or glucose
    • Cassidy, J. F., Clinton, C., Breen, W., Foster, R. & O'Donoghue, E. Novel electrochemical device for the detection of cholesterol or glucose. Analyst118, 415-418 (1993).
    • (1993) Analyst , vol.118 , pp. 415-418
    • Cassidy, J.F.1    Clinton, C.2    Breen, W.3    Foster, R.4    O'Donoghue, E.5
  • 23
    • 84987493105 scopus 로고
    • An electrochemical capillary fill device for the analysis of glucose incorporating glucose oxidase and ruthenium (III) hexamine as mediator
    • Morris, N. A., Cardosi, M. F., Birch, B. J. & Turner, A. P. F. An electrochemical capillary fill device for the analysis of glucose incorporating glucose oxidase and ruthenium (III) hexamine as mediator. Electroanal. 4, 1-9 (1992).
    • (1992) Electroanal , vol.4 , pp. 1-9
    • Morris, N.A.1    Cardosi, M.F.2    Birch, B.J.3    Turner, A.P.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.