메뉴 건너뛰기




Volumn 81, Issue 11, 2012, Pages 3614-3623

Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T

Author keywords

Artifacts; MR diffusion weighted imaging; Oncology; Whole body imaging

Indexed keywords

ADULT; AGED; ARTICLE; BLADDER; CLINICAL ARTICLE; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; ECHO PLANAR IMAGING; FEMALE; HUMAN; IMAGE ANALYSIS; LYMPH NODE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SCORING SYSTEM;

EID: 84866977438     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.11.024     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 61349123591 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging as cancer biomarker: Consensus and recommendations
    • A.R. Padhani, G. Liu, D.M. Koh, T.L. Chenevert, H.C. Thoeny, and T. Takahara Diffusion-weighted magnetic resonance imaging as cancer biomarker: consensus and recommendations Neoplasia 11 2 2009 102 125
    • (2009) Neoplasia , vol.11 , Issue.2 , pp. 102-125
    • Padhani, A.R.1    Liu, G.2    Koh, D.M.3    Chenevert, T.L.4    Thoeny, H.C.5    Takahara, T.6
  • 2
    • 4644278852 scopus 로고    scopus 로고
    • Diffusion weighted whole body imaging with background body signal suppression (DWIBS): Technical improvement using free breathing STIR and high resolution 3D display
    • T. Takahara, Y. Imai, T. Yamashita, S. Yasuda, S. Nasu, and C.M. Van Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing STIR and high resolution 3D display Radiat Med 22 4 2004 275 282
    • (2004) Radiat Med , vol.22 , Issue.4 , pp. 275-282
    • Takahara, T.1    Imai, Y.2    Yamashita, T.3    Yasuda, S.4    Nasu, S.5    Van, C.M.6
  • 4
    • 70349866279 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging with background body signal suppression (DWIBS) for the diagnosis of malignant and benign breast lesions
    • A. Stadlbauer, R. Bernt, S. Gruber, W. Bogner, K. Pinker, and R.W. van der Diffusion-weighted MR imaging with background body signal suppression (DWIBS) for the diagnosis of malignant and benign breast lesions Eur Radiol 19 10 2009 2349 2356
    • (2009) Eur Radiol , vol.19 , Issue.10 , pp. 2349-2356
    • Stadlbauer, A.1    Bernt, R.2    Gruber, S.3    Bogner, W.4    Pinker, K.5    Van Der, R.W.6
  • 5
    • 49049105451 scopus 로고    scopus 로고
    • Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): Features and potential applications in oncology
    • T.C. Kwee, T. Takahara, R. Ochiai, R.A. Nievelstein, and P.R. Luijten Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology Eur Radiol 18 9 2008 1937 1952
    • (2008) Eur Radiol , vol.18 , Issue.9 , pp. 1937-1952
    • Kwee, T.C.1    Takahara, T.2    Ochiai, R.3    Nievelstein, R.A.4    Luijten, P.R.5
  • 6
    • 77957937858 scopus 로고    scopus 로고
    • Whole-body diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient mapping for staging patients with diffuse large B-cell lymphoma
    • C. Lin, A. Luciani, E. Itti, T. El-Gnaoui, A. Vignaud, and P. Beaussart Whole-body diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient mapping for staging patients with diffuse large B-cell lymphoma Eur Radiol 20 8 2010 2027 2038
    • (2010) Eur Radiol , vol.20 , Issue.8 , pp. 2027-2038
    • Lin, C.1    Luciani, A.2    Itti, E.3    El-Gnaoui, T.4    Vignaud, A.5    Beaussart, P.6
  • 7
    • 68049145126 scopus 로고    scopus 로고
    • Detection of bone metastases in non-small cell lung cancer patients: Comparison of whole-body diffusion-weighted imaging (DWI), whole-body MR imaging without and with DWI, whole-body FDG-PET/CT, and bone scintigraphy
    • D. Takenaka, Y. Ohno, K. Matsumoto, N. Aoyama, Y. Onishi, and H. Koyama Detection of bone metastases in non-small cell lung cancer patients: comparison of whole-body diffusion-weighted imaging (DWI), whole-body MR imaging without and with DWI, whole-body FDG-PET/CT, and bone scintigraphy J Magn Reson Imaging 30 2 2009 298 308
    • (2009) J Magn Reson Imaging , vol.30 , Issue.2 , pp. 298-308
    • Takenaka, D.1    Ohno, Y.2    Matsumoto, K.3    Aoyama, N.4    Onishi, Y.5    Koyama, H.6
  • 8
    • 77952956085 scopus 로고    scopus 로고
    • Whole-body diffusion-weighted imaging vs FDG-PET for the detection of non-small-cell lung cancer. How do they measure up?
    • W. Chen, W. Jian, H.T. Li, C. Li, Y.K. Zhang, and B. Xie Whole-body diffusion-weighted imaging vs FDG-PET for the detection of non-small-cell lung cancer. How do they measure up? Magn Reson Imaging 28 5 2010 613 620
    • (2010) Magn Reson Imaging , vol.28 , Issue.5 , pp. 613-620
    • Chen, W.1    Jian, W.2    Li, H.T.3    Li, C.4    Zhang, Y.K.5    Xie, B.6
  • 9
    • 34547869766 scopus 로고    scopus 로고
    • Tumor detection by diffusion-weighted MRI and ADC-mapping - Initial clinical experiences in comparison to PET-CT
    • M.P. Lichy, P. Aschoff, C. Plathow, A. Stemmer, W. Horger, and C. Mueller-Horvat Tumor detection by diffusion-weighted MRI and ADC-mapping - initial clinical experiences in comparison to PET-CT Invest Radiol 42 9 2007 605 613
    • (2007) Invest Radiol , vol.42 , Issue.9 , pp. 605-613
    • Lichy, M.P.1    Aschoff, P.2    Plathow, C.3    Stemmer, A.4    Horger, W.5    Mueller-Horvat, C.6
  • 10
    • 37549014118 scopus 로고    scopus 로고
    • Artifacts in 3-T MRI: Physical background and reduction strategies
    • O. Dietrich, M.F. Reiser, and S.O. Schoenberg Artifacts in 3-T MRI: physical background and reduction strategies Eur J Radiol 65 1 2008 29 35
    • (2008) Eur J Radiol , vol.65 , Issue.1 , pp. 29-35
    • Dietrich, O.1    Reiser, M.F.2    Schoenberg, S.O.3
  • 12
    • 36349030254 scopus 로고    scopus 로고
    • Diffusion-weighted whole-body MR imaging with background body signal suppression: A feasibility study at 3.0 Tesla
    • P. Murtz, C. Krautmacher, F. Traber, J. Gieseke, H.H. Schild, and W.A. Willinek Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla Eur Radiol 17 12 2007 3031 3037
    • (2007) Eur Radiol , vol.17 , Issue.12 , pp. 3031-3037
    • Murtz, P.1    Krautmacher, C.2    Traber, F.3    Gieseke, J.4    Schild, H.H.5    Willinek, W.A.6
  • 13
    • 77956096409 scopus 로고    scopus 로고
    • Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: Initial clinical experience
    • W.A. Willinek, J. Gieseke, G.M. Kukuk, M. Nelles, R. Konig, and N. Morakkabati-Spitz Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: initial clinical experience Radiology 256 3 2010 966 975
    • (2010) Radiology , vol.256 , Issue.3 , pp. 966-975
    • Willinek, W.A.1    Gieseke, J.2    Kukuk, G.M.3    Nelles, M.4    Konig, R.5    Morakkabati-Spitz, N.6
  • 14
    • 78649647808 scopus 로고    scopus 로고
    • Dual-Source Parallel RF transmission for clinical MR imaging of the spine at 3.0 T: Intraindividual comparison with conventional single-source transmission
    • M. Nelles, R.S. Konig, J. Gieseke, M.M. Guerand-van Battum, G.M. Kukuk, and H.H. Schild Dual-Source Parallel RF transmission for clinical MR imaging of the spine at 3.0 T: intraindividual comparison with conventional single-source transmission Radiology 257 3 2010 743 753
    • (2010) Radiology , vol.257 , Issue.3 , pp. 743-753
    • Nelles, M.1    Konig, R.S.2    Gieseke, J.3    Guerand-Van Battum, M.M.4    Kukuk, G.M.5    Schild, H.H.6
  • 15
    • 79851491108 scopus 로고    scopus 로고
    • Complementary roles of whole-body diffusion-weighted MRI and 18F-FDG PET: The state of the art and potential applications
    • T.C. Kwee, T. Takahara, R. Ochiai, D.M. Koh, Y. Ohno, and K. Nakanishi Complementary roles of whole-body diffusion-weighted MRI and 18F-FDG PET: the state of the art and potential applications J Nucl Med 51 10 2010 1549 1558
    • (2010) J Nucl Med , vol.51 , Issue.10 , pp. 1549-1558
    • Kwee, T.C.1    Takahara, T.2    Ochiai, R.3    Koh, D.M.4    Ohno, Y.5    Nakanishi, K.6
  • 18
    • 57049090017 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging of human skeletal muscles: Gender-, age- and muscle-related differences in apparent diffusion coefficient
    • O. Yanagisawa, D. Shimao, K. Maruyama, M. Nielsen, T. Irie, and M. Niitsu Diffusion-weighted magnetic resonance imaging of human skeletal muscles: gender-, age- and muscle-related differences in apparent diffusion coefficient Magn Reson Imaging 27 1 2009 69 78
    • (2009) Magn Reson Imaging , vol.27 , Issue.1 , pp. 69-78
    • Yanagisawa, O.1    Shimao, D.2    Maruyama, K.3    Nielsen, M.4    Irie, T.5    Niitsu, M.6
  • 19
    • 77955847989 scopus 로고    scopus 로고
    • ADC measurements of lymph nodes: Inter- and intra-observer reproducibility study and an overview of the literature
    • T.C. Kwee, T. Takahara, P.R. Luijten, and R.A. Nievelstein ADC measurements of lymph nodes: inter- and intra-observer reproducibility study and an overview of the literature Eur J Radiol 75 2 2010 215 220
    • (2010) Eur J Radiol , vol.75 , Issue.2 , pp. 215-220
    • Kwee, T.C.1    Takahara, T.2    Luijten, P.R.3    Nievelstein, R.A.4
  • 20
    • 74949123772 scopus 로고    scopus 로고
    • Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen
    • B.M. Dale, A.C. Braithwaite, D.T. Boll, and E.M. Merkle Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen Invest Radiol 45 2 2010 104 108
    • (2010) Invest Radiol , vol.45 , Issue.2 , pp. 104-108
    • Dale, B.M.1    Braithwaite, A.C.2    Boll, D.T.3    Merkle, E.M.4