메뉴 건너뛰기




Volumn 156, Issue 30, 2012, Pages

Direct 'total body'-CT scan in multitrauma patients;Directe 'total body'-CT-scan bij multitraumapatiënten

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER ASSISTED TOMOGRAPHY; HUMAN; MEDICAL LITERATURE; MULTIPLE TRAUMA; SHORT SURVEY; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; COST BENEFIT ANALYSIS; ECONOMICS; INJURY; METHODOLOGY; MORTALITY; MULTICENTER STUDY; RADIOGRAPHY; RANDOMIZED CONTROLLED TRIAL; TREATMENT OUTCOME; WHOLE BODY IMAGING;

EID: 84866887175     PISSN: 00282162     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Short Survey
Times cited : (3)

References (8)
  • 1
    • 64949147862 scopus 로고    scopus 로고
    • Effect of whole-body CT during trauma resuscitation on survival: A retrospective, multicentre study
    • Huber-Wagner S, Lefering R, Qvick LM et al. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373:1455-61.
    • (2009) Lancet , vol.373 , pp. 1455-1461
    • Huber-Wagner, S.1    Lefering, R.2    Qvick, L.M.3
  • 2
    • 34147150524 scopus 로고    scopus 로고
    • Emergency room management of patients with blunt major trauma: Evaluation of the multislice computed tomography protocol exemplified by an urban trauma center
    • Weninger P, Mauritz W, Fridrich P et al. Emergency room management of patients with blunt major trauma: evaluation of the multislice computed tomography protocol exemplified by an urban trauma center. J Trauma. 2007;62:584-91.
    • (2007) J Trauma , vol.62 , pp. 584-591
    • Weninger, P.1    Mauritz, W.2    Fridrich, P.3
  • 3
    • 84555178181 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of immediate totalbody computed tomography compared with selective radiological imaging of injured patients
    • Sierink JC, Saltzherr TP, Reitsma JB, Van Delden OM, Luitse JSK, Goslings JC. Systematic review and meta-analysis of immediate totalbody computed tomography compared with selective radiological imaging of injured patients. British Journal of Surgery. 2012;99:52-8.
    • (2012) British Journal of Surgery , vol.99 , pp. 52-58
    • Sierink, J.C.1    Saltzherr, T.P.2    Reitsma, J.B.3    Van Delden, O.M.4    Luitse, J.S.K.5    Goslings, J.C.6
  • 4
    • 79953221872 scopus 로고    scopus 로고
    • Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma
    • Wurmb TE, Quaisser C, Balling H et al. Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma. Emerg Med J. 2010;28:300-4.
    • (2010) Emerg Med J , vol.28 , pp. 300-304
    • Wurmb, T.E.1    Quaisser, C.2    Balling, H.3
  • 5
    • 34247474678 scopus 로고    scopus 로고
    • New aspects in the emergency room management of critically injured patients: A multi-slice CT-oriented care algorithm
    • Hilbert P, zur NK, Hofmann GO, Hoeller I, Koch R, Stuttmann R. New aspects in the emergency room management of critically injured patients: a multi-slice CT-oriented care algorithm. Injury. 2007;38:552-8.
    • (2007) Injury , vol.38 , pp. 552-558
    • Hilbert, P.1    Zur, N.K.2    Hofmann, G.O.3    Hoeller, I.4    Koch, R.5    Stuttmann, R.6
  • 6
    • 33846794325 scopus 로고    scopus 로고
    • Whole body 16-row multislice CT in emergency room: Effects of different protocols on scanning time, image quality and radiation exposure
    • Fanucci E, Fiaschetti V, Rotili A, Floris R, Simonetti G. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure. Emerg Radiol. 2007;13:251-7.
    • (2007) Emerg Radiol , vol.13 , pp. 251-257
    • Fanucci, E.1    Fiaschetti, V.2    Rotili, A.3    Floris, R.4    Simonetti, G.5
  • 7
    • 0345015508 scopus 로고    scopus 로고
    • Radiation dose is reduced with a singlepass whole-body multidetector row CT trauma protocol compared with a conventional segmented method: Initial experience
    • Ptak T, Rhea JT, Novelline RA. Radiation dose is reduced with a singlepass whole-body multidetector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003;229:902-5.
    • (2003) Radiology , vol.229 , pp. 902-905
    • Ptak, T.1    Rhea, J.T.2    Novelline, R.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.