메뉴 건너뛰기




Volumn 199, Issue 4, 2012, Pages 794-802

Oxygen-enhanced MRI, thin-section MDCT, and perfusion SPECT/CT: Comparison of clinical implications to patient care for lung volume reduction surgery

Author keywords

CT; Emphysema; Functional imaging; Lung; MRI; SPECT

Indexed keywords

MICROAGGREGATED ALBUMIN TC 99M; OXYGEN; RADIOISOTOPE; UNCLASSIFIED DRUG;

EID: 84866869134     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.11.8250     Document Type: Article
Times cited : (18)

References (35)
  • 7
    • 0032775420 scopus 로고    scopus 로고
    • Semi-quantitative ventilation/perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: Description and prediction of clinical outcome
    • DOI 10.1007/s002590050444
    • Jamadar DA, Kazerooni EA, Martinez FJ, Wahl RL. Semi-quantitative ventilation/perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome. Eur J Nucl Med 1999; 26:734-742 (Pubitemid 29338661)
    • (1999) European Journal of Nuclear Medicine , vol.26 , Issue.7 , pp. 734-742
    • Jamadar, D.A.1    Kazerooni, E.A.2    Martinez, F.J.3    Wahl, R.L.4
  • 9
    • 0036156491 scopus 로고    scopus 로고
    • Lung volume reduction surgery for emphysema: Correlation of CT and V/Q imaging with physiologic mechanisms of improvement in lung function
    • Hunsaker AR, Ingenito EP, Reilly JJ, Costello P. Lung volume reduction surgery for emphysema: correlation of CT and V/Q imaging with physiologic mechanisms of improvement in lung function. Radiology 2002; 222:491-498 (Pubitemid 34106124)
    • (2002) Radiology , vol.222 , Issue.2 , pp. 491-498
    • Hunsaker, A.R.1    Ingenito, E.P.2    Reilly, J.J.3    Costello, P.4
  • 10
    • 18144368095 scopus 로고    scopus 로고
    • Preferential location of acute pulmonary thromboembolism induced consolidative opacities: Assessment with respiratory gated perfusion SPECT-CT fusion images
    • DOI 10.1097/00006231-200505000-00012
    • Zaki M, Suga K, Kawakami Y, et al. Preferential location of acute pulmonary thromboembolism induced consolidative opacities: assessment with respiratory gated perfusion SPECT-CT fusion images. Nucl Med Commun 2005; 26:465-474 (Pubitemid 40617736)
    • (2005) Nuclear Medicine Communications , vol.26 , Issue.5 , pp. 465-474
    • Zaki, M.1    Suga, K.2    Kawakami, Y.3    Yamashita, T.4    Shimizu, K.5    Seto, A.6    Matsunaga, N.7
  • 11
    • 34250163586 scopus 로고    scopus 로고
    • Coregistered Ventilation and Perfusion SPECT Using Krypton-81m and Tc-99m-Labeled Macroaggregated Albumin With Multislice CT. Utility for Prediction of Postoperative Lung Function in Non-Small Cell Lung Cancer Patients
    • DOI 10.1016/j.acra.2007.03.013, PII S107663320700178X
    • Ohno Y, Koyama H, Takenaka D, et al. Coregistered ventilation and perfusion SPECT using krypton-81m and Tc-99m-labeled macroaggregated albumin with multislice CT utility for prediction of postoperative lung function in nonsmall cell lung cancer patients. Acad Radiol 2007; 14:830-838 (Pubitemid 46898851)
    • (2007) Academic Radiology , vol.14 , Issue.7 , pp. 830-838
    • Ohno, Y.1    Koyama, H.2    Takenaka, D.3    Nogami, M.4    Kotani, Y.5    Nishimura, Y.6    Yoshimura, M.7    Yoshikawa, T.8    Sugimura, K.9
  • 12
    • 77952879604 scopus 로고    scopus 로고
    • Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates
    • Takenaka D, Ohno Y, Koyama H, et al. Co-registered perfusion SPECT/CT: utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates. Eur J Radiol 2010; 74:465-472
    • (2010) Eur J Radiol , vol.74 , pp. 465-472
    • Takenaka, D.1    Ohno, Y.2    Koyama, H.3
  • 13
    • 43449096389 scopus 로고    scopus 로고
    • Radiographic evaluation of the potential lung volume reduction surgery candidate
    • DOI 10.1513/pats.200802-017ET
    • Washko GR, Hoffman E, Reilly JJ. Radiographic evaluation of the potential lung volume reduction surgery candidate. Proc Am Thorac Soc 2008; 5:421-426 (Pubitemid 351669164)
    • (2008) Proceedings of the American Thoracic Society , vol.5 , Issue.4 , pp. 421-426
    • Washko, G.R.1    Hoffman, E.2    Reilly, J.J.3
  • 15
    • 0030947381 scopus 로고    scopus 로고
    • Perfusion lung scintigraphy for the prediction of postlobectomy residual pulmonary function
    • Giordano A, Calcagni ML, Meduri G, Valente S, Galli G. Perfusion lung scintigraphy for the prediction of postlobectomy residual pulmonary function. Chest 1997; 111:1542-1547 (Pubitemid 27260080)
    • (1997) Chest , vol.111 , Issue.6 , pp. 1542-1547
    • Giordano, A.1    Calcagni, M.L.2    Meduri, G.3    Valente, S.4    Galli, G.5
  • 16
    • 0033380191 scopus 로고    scopus 로고
    • Rationale and design of the National Emphysema Treatment Trial: A prospective randomized trial of lung volume reduction surgery
    • The National Emphysema Treatment Trial Research Group
    • The National Emphysema Treatment Trial Research Group. Rationale and design of the National Emphysema Treatment Trial: a prospective randomized trial of lung volume reduction surgery. Chest 1999; 116:1750-1761
    • (1999) Chest , vol.116 , pp. 1750-1761
  • 17
    • 0036136992 scopus 로고    scopus 로고
    • Emphysema: Hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes - Initial experience
    • Salerno M, de Lange EE, Altes TA, Truwit JD, Brookeman JR, Mugler JP 3rd. Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes-initial experience. Radiology 2002; 222:252-260 (Pubitemid 34031496)
    • (2002) Radiology , vol.222 , Issue.1 , pp. 252-260
    • Salerno, M.1    De Lange, E.E.2    Altes, T.A.3    Truwit, J.D.4    Brookeman, J.R.5    Mugler III, J.P.6
  • 19
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging
    • DOI 10.1038/nm1196-1236
    • Edelman RR, Hatabu H, Tadamura E, Li W, Prasad PV. Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging. Nat Med 1996; 2:1236-1239 (Pubitemid 26375408)
    • (1996) Nature Medicine , vol.2 , Issue.11 , pp. 1236-1239
    • Edelman, R.R.1    Hatabu, H.2    Tadamura, E.3    Li, W.4    Prasad, P.V.5
  • 24
    • 38949160498 scopus 로고    scopus 로고
    • Dynamic oxygen-enhanced MRI versus quantitative CT: Pulmonary functional loss assessment and clinical stage classification of smoking-related COPD
    • web
    • Ohno Y, Koyama H, Nogami M, et al. Dynamic oxygen-enhanced MRI versus quantitative CT: pulmonary functional loss assessment and clinical stage classification of smoking-related COPD. AJR 2008; 190:327; [web]W93-W99
    • (2008) AJR , vol.190
    • Ohno, Y.1    Koyama, H.2    Nogami, M.3
  • 26
    • 0017759609 scopus 로고
    • Multifactorial index of cardiac risk in noncardiac surgical procedures
    • Goldman L, Caldera DL, Nussbaum SR, et al. Multifactorial index of cardiac risk in noncardiac surgical procedures. N Engl J Med 1977; 297:845-850 (Pubitemid 8200494)
    • (1977) New England Journal of Medicine , vol.297 , Issue.16 , pp. 845-850
    • Goldman, L.1    Caldera, D.L.2    Nussbaum, S.R.3
  • 27
    • 0035846315 scopus 로고    scopus 로고
    • Patients at high risk of death after lung-volume- Reduction surgery
    • National Emphysema Treatment Trial Research Group
    • National Emphysema Treatment Trial Research Group. Patients at high risk of death after lung-volume- reduction surgery. N Engl J Med 2001; 345:1075-1083
    • (2001) N Engl J Med , vol.345 , pp. 1075-1083
  • 28
    • 0026772581 scopus 로고
    • An automated method for rotational correction and centering of three-dimensional functional brain images
    • Minoshima S, Berger KL, Lee KS, Mintun MA. An automated method for rotational correction and centering of three-dimensional functional brain images. J Nucl Med 1992; 33:1579-1585
    • (1992) J Nucl Med , vol.33 , pp. 1579-1585
    • Minoshima, S.1    Berger, K.L.2    Lee, K.S.3    Mintun, M.A.4
  • 29
    • 0029040216 scopus 로고
    • A diagnostic approach in Alzheimer's disease using three-dimensional stereotactic surface projections of fluorine-18-FDG PET
    • Minoshima S, Frey KA, Koeppe RA, Foster NL, Kuhl DE. A diagnostic approach in Alzheimer's disease using three-dimensional stereotactic surface projections of fluorine-18-FDG PET. J Nucl Med 1995; 36:1238-1248
    • (1995) J Nucl Med , vol.36 , pp. 1238-1248
    • Minoshima, S.1    Frey, K.A.2    Koeppe, R.A.3    Foster, N.L.4    Kuhl, D.E.5
  • 30
    • 0023442646 scopus 로고
    • Standardization of spirometry: 1987 update
    • American Thoracic Society
    • American Thoracic Society. Standardization of spirometry: 1987 update. Am Rev Respir Dis 1987; 136:1285-1298
    • (1987) Am Rev Respir Dis , vol.136 , pp. 1285-1298
  • 31
    • 0026038935 scopus 로고
    • Lung function testing: Selection of reference values and interpretative strategies
    • American Thoracic Society
    • American Thoracic Society. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis 1991; 144:1202-1218
    • (1991) Am Rev Respir Dis , vol.144 , pp. 1202-1218
  • 32
    • 0026696563 scopus 로고
    • The measurement of dyspnea during exercise in patients with lung disease
    • Mahler DA. The measurement of dyspnea during exercise in patients with lung disease. Chest 1992; 101(5 suppl):S242-S247
    • (1992) Chest , vol.101 , Issue.5 SUPPL.
    • Mahler, D.A.1
  • 33
    • 0021834116 scopus 로고
    • How should we measure function in patients with chronic heart and lung disease?
    • DOI 10.1016/0021-9681(85)90035-9
    • Guyatt GH, Thompson PJ, Berman LB, et al. How should we measure function in patients with chronic heart and lung disease? J Chronic Dis 1985; 38:517-524 (Pubitemid 15036757)
    • (1985) Journal of Chronic Diseases , vol.38 , Issue.6 , pp. 517-524
    • Guyatt, G.H.1    Thompson, P.J.2    Berman, L.B.3
  • 34
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327:307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 35
    • 0024459172 scopus 로고
    • Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
    • Svanholm H, Starklint H, Gundersen HJ, Fabricius J, Barlebo H, Olsen S. Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic. APMIS 1989; 97:689-698 (Pubitemid 19217684)
    • (1989) APMIS , vol.97 , Issue.8 , pp. 689-698
    • Svanholm, H.1    Starklint, H.2    Gundersen, H.J.G.3    Fabricius, J.4    Barlebo, H.5    Olsen, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.