메뉴 건너뛰기




Volumn 88, Issue 11, 2012, Pages 853-859

Normal values of left and right ventricular function measured by ℐmode, pulsed doppler and Doppler tissue imaging in healthy term neonates during a ℐyear period

Author keywords

Doppler tissue imaging; Echocardiography; Healthy term newborn; Myocardial performance index; Pulsed Doppler

Indexed keywords

ARTICLE; CARDIAC IMAGING; FEMALE; FLOW RATE; HEART ATRIOVENTRICULAR VALVE; HEART HEMODYNAMICS; HEART LEFT VENTRICLE FUNCTION; HEART PERFORMANCE; HEART RIGHT VENTRICLE FUNCTION; HUMAN; INFANT; MALE; MEASUREMENT; MITRAL VALVE; NEWBORN; NORMAL HUMAN; TISSUE DOPPLER IMAGING; TRICUSPID VALVE; VELOCITY;

EID: 84866851787     PISSN: 03783782     EISSN: 18726232     Source Type: Journal    
DOI: 10.1016/j.earlhumdev.2012.06.006     Document Type: Article
Times cited : (29)

References (33)
  • 1
    • 0034180804 scopus 로고    scopus 로고
    • Tissue Doppler imaging of left and right ventricles in normal children
    • Harada K., Orino T., Yasuoka K., Tamura M., Takada G. Tissue Doppler imaging of left and right ventricles in normal children. Tohoku J Exp Med 2000, 191:21-29.
    • (2000) Tohoku J Exp Med , vol.191 , pp. 21-29
    • Harada, K.1    Orino, T.2    Yasuoka, K.3    Tamura, M.4    Takada, G.5
  • 3
    • 0036662886 scopus 로고    scopus 로고
    • Left ventricular systolic and diastolic function during early neonatal period using transthoracic echocardiography
    • Shiota T., Harada K., Takada G. Left ventricular systolic and diastolic function during early neonatal period using transthoracic echocardiography. Tohoku J Exp Med 2002, 197:151-158.
    • (2002) Tohoku J Exp Med , vol.197 , pp. 151-158
    • Shiota, T.1    Harada, K.2    Takada, G.3
  • 4
    • 0029586902 scopus 로고
    • New index of combined systolic and diastolic myocardial performance: a simple and reproducible measure of cardiac function-a study in normals and dilated cardiomyopathy
    • Tei C., Ling L.H., Hodge D.O., Bailey K.R., Oh J.K., Rodeheffer R.J., et al. New index of combined systolic and diastolic myocardial performance: a simple and reproducible measure of cardiac function-a study in normals and dilated cardiomyopathy. J Cardiol 1995, 26:357-366.
    • (1995) J Cardiol , vol.26 , pp. 357-366
    • Tei, C.1    Ling, L.H.2    Hodge, D.O.3    Bailey, K.R.4    Oh, J.K.5    Rodeheffer, R.J.6
  • 5
    • 77957110538 scopus 로고    scopus 로고
    • Cardiac involvement in perinatal asphyxia (myoglobilin, creatinin kinase myocardial band, troponin I and myocardial performance index)
    • Dogan M., Mese T., Dizdarer C. Cardiac involvement in perinatal asphyxia (myoglobilin, creatinin kinase myocardial band, troponin I and myocardial performance index). Türkiye Klinikleri J Pediatr 2004, 13:207-212.
    • (2004) Türkiye Klinikleri J Pediatr , vol.13 , pp. 207-212
    • Dogan, M.1    Mese, T.2    Dizdarer, C.3
  • 7
    • 0033653889 scopus 로고    scopus 로고
    • Left ventricular wall motion velocities in healthy children measured by pulsed wave Doppler tissue echocardiography:normal values and relation to age heart rate
    • Mori K., Hayabuchi Y., Kuroda Y., Nii M., Manabe T. Left ventricular wall motion velocities in healthy children measured by pulsed wave Doppler tissue echocardiography:normal values and relation to age heart rate. J Am Soc Echocardiogr 2000, 13:1002-1011.
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 1002-1011
    • Mori, K.1    Hayabuchi, Y.2    Kuroda, Y.3    Nii, M.4    Manabe, T.5
  • 8
    • 0037941321 scopus 로고    scopus 로고
    • Usefulness of a new Doppler index for assessing both ventricular functions and pulmonary circulation in newborn piglet with hypoxic pulmonary hypertension
    • Sugiura T., Suzuki S., Hussein M.H., Kato T., Togari H. Usefulness of a new Doppler index for assessing both ventricular functions and pulmonary circulation in newborn piglet with hypoxic pulmonary hypertension. Pediatr Res 2003, 53:927-932.
    • (2003) Pediatr Res , vol.53 , pp. 927-932
    • Sugiura, T.1    Suzuki, S.2    Hussein, M.H.3    Kato, T.4    Togari, H.5
  • 10
    • 77951732397 scopus 로고    scopus 로고
    • Recommendations for quantification methods during the performance of a pediatric echocardiogram: a report from the pediatric measurements writing group of the American Society of Echocardiography Pediatric and Congenital Heart Disease Council
    • Lopez L., Colan S.D., Frommelt P.C., Ensing G.J., Kendall K., Younoszai A.K., et al. Recommendations for quantification methods during the performance of a pediatric echocardiogram: a report from the pediatric measurements writing group of the American Society of Echocardiography Pediatric and Congenital Heart Disease Council. J Am Soc Echocardiogr 2010, 23:465-495.
    • (2010) J Am Soc Echocardiogr , vol.23 , pp. 465-495
    • Lopez, L.1    Colan, S.D.2    Frommelt, P.C.3    Ensing, G.J.4    Kendall, K.5    Younoszai, A.K.6
  • 11
    • 45849110596 scopus 로고    scopus 로고
    • European association of echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies
    • Evangelista A., Flachskampf F., Lancellotti P., Badano L., Aguilar R., Monaghan M., et al. European association of echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies. Eur J Echocardiogr 2008, 9:438-448.
    • (2008) Eur J Echocardiogr , vol.9 , pp. 438-448
    • Evangelista, A.1    Flachskampf, F.2    Lancellotti, P.3    Badano, L.4    Aguilar, R.5    Monaghan, M.6
  • 12
    • 33751307960 scopus 로고    scopus 로고
    • Left ventricular Tei index in children: comparison of tissue Doppler imaging pulsed wave Doppler, and M-mode echocardiography normal values
    • Cui W., Roberson D.A. Left ventricular Tei index in children: comparison of tissue Doppler imaging pulsed wave Doppler, and M-mode echocardiography normal values. J Am Soc Echocardiogr 2006, 19:1438-1445.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1438-1445
    • Cui, W.1    Roberson, D.A.2
  • 13
    • 85075388606 scopus 로고    scopus 로고
    • Assessment of ventricular and myocardial performance
    • Saunders Elsevier, Philadelphia, J.F. Keane, J.E. Lock, D.C. Fyler (Eds.)
    • Colan S.D. Assessment of ventricular and myocardial performance. Nadas's pediatric cardiology 2006, 251-273. Saunders Elsevier, Philadelphia. 2nd ed. J.F. Keane, J.E. Lock, D.C. Fyler (Eds.).
    • (2006) Nadas's pediatric cardiology , pp. 251-273
    • Colan, S.D.1
  • 14
    • 0030751956 scopus 로고    scopus 로고
    • Assessment of mitral annulus velocity by Doppler tissue imaging in evaluation of left ventricular diastolic function
    • Sohn D.W., Chai I.H., Lee D.J., Kim H.C., Kim H.S., Oh B.H., et al. Assessment of mitral annulus velocity by Doppler tissue imaging in evaluation of left ventricular diastolic function. J Am Coll Cardiol 1997, 30:474-480.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 474-480
    • Sohn, D.W.1    Chai, I.H.2    Lee, D.J.3    Kim, H.C.4    Kim, H.S.5    Oh, B.H.6
  • 15
    • 0742290218 scopus 로고    scopus 로고
    • Pulsed wave Doppler tissue echocardiography assessment of the long axis function of the right and left ventricles during the early neonatal period
    • Mori K., Nakagawa R., Nii M., Edagawa T., Takehara Y., Inoue M., et al. Pulsed wave Doppler tissue echocardiography assessment of the long axis function of the right and left ventricles during the early neonatal period. Heart 2004, 90:175-180.
    • (2004) Heart , vol.90 , pp. 175-180
    • Mori, K.1    Nakagawa, R.2    Nii, M.3    Edagawa, T.4    Takehara, Y.5    Inoue, M.6
  • 17
    • 0032031694 scopus 로고    scopus 로고
    • Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography
    • Galiuto L., Ignone G., DeMaria A.N. Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol 1998, 81:609-614.
    • (1998) Am J Cardiol , vol.81 , pp. 609-614
    • Galiuto, L.1    Ignone, G.2    DeMaria, A.N.3
  • 18
    • 0023200419 scopus 로고
    • Preload dependency of Doppler-derived indices of left ventricular diastolic function in humans
    • Choong C.Y., Herrmann H.C., Weyman A.E., Fifer M.A. Preload dependency of Doppler-derived indices of left ventricular diastolic function in humans. J Am Coll Cardiol 1987, 10:800-808.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 800-808
    • Choong, C.Y.1    Herrmann, H.C.2    Weyman, A.E.3    Fifer, M.A.4
  • 19
    • 0024319475 scopus 로고
    • Influence of alteration in preload on the pattern of left ventricular diastolic filling assessed by Doppler echocardiography in humans
    • Stoddard M.F., Pearson A.C., Kern M.J., Ratcliff J., Mrosek D.G., Labovitz A.J. Influence of alteration in preload on the pattern of left ventricular diastolic filling assessed by Doppler echocardiography in humans. Circulation 1989, 79:1226-1236.
    • (1989) Circulation , vol.79 , pp. 1226-1236
    • Stoddard, M.F.1    Pearson, A.C.2    Kern, M.J.3    Ratcliff, J.4    Mrosek, D.G.5    Labovitz, A.J.6
  • 20
    • 0031802261 scopus 로고    scopus 로고
    • Diastolic ventricular function in children: a Doppler echocardiographic study establishing normal values and predictors of increased ventricular end diastolic pressure
    • O'Leary P.W., Durongpisitkul K., Cordes T.M., Bailey K.R., Hagler D.J., Tajik J., et al. Diastolic ventricular function in children: a Doppler echocardiographic study establishing normal values and predictors of increased ventricular end diastolic pressure. Mayo Clin Proc 1998, 73:616-628.
    • (1998) Mayo Clin Proc , vol.73 , pp. 616-628
    • O'Leary, P.W.1    Durongpisitkul, K.2    Cordes, T.M.3    Bailey, K.R.4    Hagler, D.J.5    Tajik, J.6
  • 21
    • 33645278351 scopus 로고    scopus 로고
    • Differentiation of left ventricular diastolic dysfunction, identification of pseudonormal/restrictive mitral inflow pattern and determination of left ventricular filling pressure by Tei index obtained from tissue Doppler echocardiography
    • Su H.M., Lin T.H., Voon W.C., Lee K.T., Chu C.S., Lai W.T., et al. Differentiation of left ventricular diastolic dysfunction, identification of pseudonormal/restrictive mitral inflow pattern and determination of left ventricular filling pressure by Tei index obtained from tissue Doppler echocardiography. Echocardiography 2006, 23:287-294.
    • (2006) Echocardiography , vol.23 , pp. 287-294
    • Su, H.M.1    Lin, T.H.2    Voon, W.C.3    Lee, K.T.4    Chu, C.S.5    Lai, W.T.6
  • 22
    • 0025311880 scopus 로고
    • The effects of increasing mean arterial pressure of left ventricular output in newborn lambs
    • Van Hare G.E., Schmidt K.G., Rudolph A.M. The effects of increasing mean arterial pressure of left ventricular output in newborn lambs. Circ Res 1990, 67:78-83.
    • (1990) Circ Res , vol.67 , pp. 78-83
    • Van Hare, G.E.1    Schmidt, K.G.2    Rudolph, A.M.3
  • 23
    • 0029049653 scopus 로고
    • Quantitative Doppler tissue imaging of the left ventricular myocardium: validation in normal subjects
    • Donovan C.L., Armstrong W.F., Bach D.S. Quantitative Doppler tissue imaging of the left ventricular myocardium: validation in normal subjects. Am Heart J 1995, 130:100-104.
    • (1995) Am Heart J , vol.130 , pp. 100-104
    • Donovan, C.L.1    Armstrong, W.F.2    Bach, D.S.3
  • 24
    • 0031946462 scopus 로고    scopus 로고
    • Amplitudes, durations, and timings of apically directed left ventricular myocardial velocities, their normal pattern and coupling to ventricular filling and ejection
    • Pai R.G., Kanwaljit S.G. Amplitudes, durations, and timings of apically directed left ventricular myocardial velocities, their normal pattern and coupling to ventricular filling and ejection. J Am Soc Echocardiogr 1998, 11:105-111.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 105-111
    • Pai, R.G.1    Kanwaljit, S.G.2
  • 25
    • 77955813603 scopus 로고    scopus 로고
    • Reference values of tissue Doppler imaging and pulsed Doppler echocardiography for analysis of left ventricular diastolic function in healthy adults
    • Angelo L.C., Vieira M.L.C., Rodrigues S.L., Morelato R., Pereira A.C., Mill J.G., et al. Reference values of tissue Doppler imaging and pulsed Doppler echocardiography for analysis of left ventricular diastolic function in healthy adults. Echocardiography 2010, 27:777-782.
    • (2010) Echocardiography , vol.27 , pp. 777-782
    • Angelo, L.C.1    Vieira, M.L.C.2    Rodrigues, S.L.3    Morelato, R.4    Pereira, A.C.5    Mill, J.G.6
  • 26
    • 0030698732 scopus 로고    scopus 로고
    • Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures
    • Nagueh S.F., Middleton K.J., Kopelen H.A., Zoghbi W.A., Quinones M.A. Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. J Am Coll Cardiol 1997, 30:1527-1533.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1527-1533
    • Nagueh, S.F.1    Middleton, K.J.2    Kopelen, H.A.3    Zoghbi, W.A.4    Quinones, M.A.5
  • 27
    • 0035345554 scopus 로고    scopus 로고
    • A comparison of tissue Doppler imaging and velocities of transmitral flow in children with elevated left ventricular preload
    • Harada K., Tamura M., Yasuoka K., Toyono M. A comparison of tissue Doppler imaging and velocities of transmitral flow in children with elevated left ventricular preload. Cardiol Young 2001, 11:261-268.
    • (2001) Cardiol Young , vol.11 , pp. 261-268
    • Harada, K.1    Tamura, M.2    Yasuoka, K.3    Toyono, M.4
  • 28
    • 0034633812 scopus 로고    scopus 로고
    • Cinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures
    • Ommen S.R., Nishimura R.A., Appleton C.P., Miller F.A., Oh J.K., Redfield M.M., et al. Cinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures. Circulation 2000, 102:1788-1794.
    • (2000) Circulation , vol.102 , pp. 1788-1794
    • Ommen, S.R.1    Nishimura, R.A.2    Appleton, C.P.3    Miller, F.A.4    Oh, J.K.5    Redfield, M.M.6
  • 29
    • 0034670118 scopus 로고    scopus 로고
    • Quantitative assessment of ventricular function in children with single ventricles using the Doppler myocardial performance index
    • Williams R.V., Ritter S., Tani L.Y., Pagotto L.T., Minich L.L. Quantitative assessment of ventricular function in children with single ventricles using the Doppler myocardial performance index. Am J Cardiol 2000, 86:1106-1110.
    • (2000) Am J Cardiol , vol.86 , pp. 1106-1110
    • Williams, R.V.1    Ritter, S.2    Tani, L.Y.3    Pagotto, L.T.4    Minich, L.L.5
  • 30
    • 29244435772 scopus 로고    scopus 로고
    • Left ventricle myocardial performance index derived either by conventional method or mitral annulus tissue-Doppler: a comparison study in healthy subjects and subjects with heart failure
    • Gaibazzi N., Petrucci N., Ziacchi V., del Garda D. Left ventricle myocardial performance index derived either by conventional method or mitral annulus tissue-Doppler: a comparison study in healthy subjects and subjects with heart failure. J Am Soc Echocardiogr 2005, 18:1270-1276.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1270-1276
    • Gaibazzi, N.1    Petrucci, N.2    Ziacchi, V.3    del Garda, D.4
  • 31
    • 0035887253 scopus 로고    scopus 로고
    • Assessment of gobal left ventricular systolic ventricular systolic function by tissue Doppler imaging
    • Harada K., Tamura M., Toyono M., Oyama K., Takada G. Assessment of gobal left ventricular systolic ventricular systolic function by tissue Doppler imaging. Am J Cardiol 2001, 88:927-932.
    • (2001) Am J Cardiol , vol.88 , pp. 927-932
    • Harada, K.1    Tamura, M.2    Toyono, M.3    Oyama, K.4    Takada, G.5
  • 32
    • 9644275600 scopus 로고    scopus 로고
    • Measurement of the Tei index: a comparison of M-mode and pulsed Doppler methods
    • Tham E.B.C., Silverman N.H. Measurement of the Tei index: a comparison of M-mode and pulsed Doppler methods. J Am Soc Echocardiogr 2004, 17:259-265.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 259-265
    • Tham, E.B.C.1    Silverman, N.H.2
  • 33
    • 34249316182 scopus 로고    scopus 로고
    • Right ventricular Tei index in children: effect of method, age, body surface area, and heart rate
    • Roberson D.A., Cui W. Right ventricular Tei index in children: effect of method, age, body surface area, and heart rate. J Am Soc Echocardiogr 2007, 20:764-770.
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 764-770
    • Roberson, D.A.1    Cui, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.