메뉴 건너뛰기




Volumn 86, Issue 11, 2012, Pages 3331-3344

Theoretical and experimental analysis of a novel low emissivity water pond in summer

Author keywords

Energy efficiency; Low emissivity; Passive cooling; Roof pond

Indexed keywords

ENERGY FLUXES; EVAPORATIVE HEAT LOSS; EXPERIMENTAL ANALYSIS; EXPERIMENTAL STUDIES; FUNCTIONAL DEMANDS; LOW EMISSIVITY; PASSIVE COOLING; RADIATION LOSS; ROOF COOLING; ROOF PONDS; WATER EVAPORATION;

EID: 84866780421     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2012.08.017     Document Type: Article
Times cited : (15)

References (21)
  • 1
    • 0004566174 scopus 로고
    • MIT Press, Cambridge, MA
    • Cook J. Passive Cooling 1985, MIT Press, Cambridge, MA.
    • (1985) Passive Cooling
    • Cook, J.1
  • 2
    • 84867863477 scopus 로고
    • Passive and Low Energy Cooling of Buildings.
    • Givoni, B., 1994. Passive and Low Energy Cooling of Buildings.
    • (1994)
    • Givoni, B.1
  • 3
    • 79959903739 scopus 로고    scopus 로고
    • Indoor temperature reduction by passive cooling systems
    • Givoni B. Indoor temperature reduction by passive cooling systems. Solar Energy 2011, 85:1692-1726.
    • (2011) Solar Energy , vol.85 , pp. 1692-1726
    • Givoni, B.1
  • 4
    • 34548438950 scopus 로고    scopus 로고
    • Roof pond cooling of buildings in hot arid climates
    • Kharrufa Sahar N., Yahyah Adil Roof pond cooling of buildings in hot arid climates. Building and Environment 2008, 43:82-89.
    • (2008) Building and Environment , vol.43 , pp. 82-89
    • Kharrufa, S.N.1    Yahyah, A.2
  • 6
    • 0033883325 scopus 로고    scopus 로고
    • Skytherm: an approach to year-round thermal energy sufficient houses
    • Raeissi S., Taheri M. Skytherm: an approach to year-round thermal energy sufficient houses. Renewable Energy 2008, 19:527-543.
    • (2008) Renewable Energy , vol.19 , pp. 527-543
    • Raeissi, S.1    Taheri, M.2
  • 8
    • 37849001379 scopus 로고    scopus 로고
    • A review on the generation, determination and mitigation of urban heat island
    • Rizwan A.M., Dennis L.Y.C., Liu C. A review on the generation, determination and mitigation of urban heat island. Journal of Environmental Sciences 2008, 20(1):120-128.
    • (2008) Journal of Environmental Sciences , vol.20 , Issue.1 , pp. 120-128
    • Rizwan, A.M.1    Dennis, L.Y.C.2    Liu, C.3
  • 10
    • 84857125605 scopus 로고    scopus 로고
    • Using cool paving materials to improve microclimate of urban areas - design realization and results of the Flisvos project
    • Santamouris M., Gaitani N., Spanou A., Saliari M., Giannopoulou K., Vasilakopoulou K., et al. Using cool paving materials to improve microclimate of urban areas - design realization and results of the Flisvos project. Building and Environment 2012, 53(5-6):128-136.
    • (2012) Building and Environment , vol.53 , Issue.5-6 , pp. 128-136
    • Santamouris, M.1    Gaitani, N.2    Spanou, A.3    Saliari, M.4    Giannopoulou, K.5    Vasilakopoulou, K.6
  • 11
    • 79960921131 scopus 로고    scopus 로고
    • Using advanced cool materials in the urban built environment to mitigate heat islands and improve thermal comfort conditions
    • Santamouris M., Synnefa A., Karlessi T. Using advanced cool materials in the urban built environment to mitigate heat islands and improve thermal comfort conditions. Solar Energy 2011, 85(12):3085-3102.
    • (2011) Solar Energy , vol.85 , Issue.12 , pp. 3085-3102
    • Santamouris, M.1    Synnefa, A.2    Karlessi, T.3
  • 14
    • 84867867729 scopus 로고    scopus 로고
    • in press. Advances on technical, policy and market aspects of cool roof technology in Europe: The Cool Roofs project. Energy and Buildings.
    • Synnefa, A., Santamouris, M., in press. Advances on technical, policy and market aspects of cool roof technology in Europe: The Cool Roofs project. Energy and Buildings.
    • Synnefa, A.1    Santamouris, M.2
  • 15
    • 14644435719 scopus 로고    scopus 로고
    • Cooling performance of roof ponds with gunny bags floating on water surface as compared with a movable insulation
    • Tang R., Etzion Y. Cooling performance of roof ponds with gunny bags floating on water surface as compared with a movable insulation. Renewable Energy 2005, 30:1373-1385.
    • (2005) Renewable Energy , vol.30 , pp. 1373-1385
    • Tang, R.1    Etzion, Y.2
  • 16
    • 0037411799 scopus 로고    scopus 로고
    • Experimental studies on a novel roof pond configuration for the cooling of buildings
    • Tang R., Etzion Y., Erell E. Experimental studies on a novel roof pond configuration for the cooling of buildings. Renewable Energy 2003, 28:1513-1522.
    • (2003) Renewable Energy , vol.28 , pp. 1513-1522
    • Tang, R.1    Etzion, Y.2    Erell, E.3
  • 17
    • 0345375476 scopus 로고    scopus 로고
    • On thermal performance of improved roof pond for cooling buildings
    • Tang R.S., Etzion Y. On thermal performance of improved roof pond for cooling buildings. Build Environment 2004, 39:201-209.
    • (2004) Build Environment , vol.39 , pp. 201-209
    • Tang, R.S.1    Etzion, Y.2
  • 18
    • 0242306121 scopus 로고    scopus 로고
    • Comparative studies on the water evaporation rate from a wetted surface and that from a free water surface
    • Tang R.S., Etzion Y. Comparative studies on the water evaporation rate from a wetted surface and that from a free water surface. Building Environment 2004, 39:77-86.
    • (2004) Building Environment , vol.39 , pp. 77-86
    • Tang, R.S.1    Etzion, Y.2
  • 19
    • 1642282140 scopus 로고    scopus 로고
    • Estimates of clear night sky emissivity in the Negev Highlands, Israel
    • Tang R.S., Etzion Y., Meir I.A. Estimates of clear night sky emissivity in the Negev Highlands, Israel. Energy Conversion and Management 2004, 45:1831-1843.
    • (2004) Energy Conversion and Management , vol.45 , pp. 1831-1843
    • Tang, R.S.1    Etzion, Y.2    Meir, I.A.3
  • 20
    • 0020612319 scopus 로고
    • Digital simulation of indoor temperatures of buildings with roof ponds
    • Yadav R., Rao D.F. Digital simulation of indoor temperatures of buildings with roof ponds. Solar Energy 1983, 31(2):205-215.
    • (1983) Solar Energy , vol.31 , Issue.2 , pp. 205-215
    • Yadav, R.1    Rao, D.F.2
  • 21
    • 84867880638 scopus 로고    scopus 로고
    • in press. Cool and green roofs. An energy and comfort comparison between passive cooling and mitigation urban heat island techniques for residential buildings in the mediterranean region. Energy and Buildings.
    • Zinzi, M., Agnoli, S., in press. Cool and green roofs. An energy and comfort comparison between passive cooling and mitigation urban heat island techniques for residential buildings in the mediterranean region. Energy and Buildings.
    • Zinzi, M.1    Agnoli, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.