메뉴 건너뛰기




Volumn 27, Issue 4, 2012, Pages 2304-2311

Stray current effects mitigation in subway tunnels

Author keywords

Equipotential connection; finite element method (FEM) analysis; stray current; tramway and subway transportation

Indexed keywords

DESIGN PROCEDURE; ENVIRONMENTAL COMPATIBILITY; EQUIPOTENTIAL CONNECTION; FINITE ELEMENT METHOD ANALYSIS; INTERNATIONAL STANDARDS; PRECAUTIONARY MEASURES; REINFORCEMENT BAR; STRAY CURRENT; SUBWAY TUNNELS; TRANSIT SYSTEMS; TRANSPORTATION SERVICES;

EID: 84866733212     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2012.2203829     Document Type: Article
Times cited : (73)

References (18)
  • 1
    • 33750107084 scopus 로고    scopus 로고
    • Assessment of grounding schemes on rail potential and stray currents in a DC transit system
    • Oct.
    • L. Chien-Hsing and L. Chien-Jung, "Assessment of grounding schemes on rail potential and stray currents in a DC transit system," IEEE Trans. Power Del., vol. 21, no. 4, pp. 1941-1947, Oct. 2006.
    • (2006) IEEE Trans. Power Del. , vol.21 , Issue.4 , pp. 1941-1947
    • Chien-Hsing, L.1    Chien-Jung, L.2
  • 4
    • 68949219502 scopus 로고    scopus 로고
    • Effects of different earthing schemes on the stray current in rail transit systems
    • Sep. 1-4
    • S. Jamali, M. M. Alamuti, and M. Savaghebi, "Effects of different earthing schemes on the stray current in rail transit systems," in Proc. 43rd Int. Univ. Power Eng. Conf., Sep. 1-4, 2008, pp. 1-5.
    • (2008) Proc. 43rd Int. Univ. Power Eng. Conf. , pp. 1-5
    • Jamali, S.1    Alamuti, M.M.2    Savaghebi, M.3
  • 5
    • 19344376685 scopus 로고    scopus 로고
    • Control scheme for reducing rail potential and stray current in MRT systems
    • DOI 10.1049/ip-epa:20045042
    • Y. C. Liu and J. F. Chen, "Control scheme for reducing rail potential and stray current in MRT systems," in Proc. Inst. Elect. Eng., Elect. Power Appl., May 2005, vol. 152, no. 3, 6, pp. 612-618. (Pubitemid 40718421)
    • (2005) IEE Proceedings: Electric Power Applications , vol.152 , Issue.3 , pp. 612-618
    • Liu, Y.C.1    Chen, J.F.2
  • 6
    • 51349162131 scopus 로고    scopus 로고
    • Stray current automatic monitoring system and intelligent obviating, current device in metro
    • Dec. 3-6
    • M. Longhua and Zhouwei, "Stray current automatic monitoring system and intelligent obviating, current device in metro," in Proc. Int. Power Eng. Conf., Dec. 3-6, 2007, pp. 1070-1074.
    • (2007) Proc. Int. Power Eng. Conf. , pp. 1070-1074
    • Longhua, M.1    Zhouwe, I.2
  • 7
    • 20444472389 scopus 로고    scopus 로고
    • Stray current monitoring and control on singapore MRT system
    • 2004 International Conference on Power System Technology, POWERCON 2004
    • W. M. Sim and C. F. Chan, "Stray current monitoring and control on singaporeMRT system," in Proc. Int. Conf. Power Syst. Technol., Nov. 21-24, 2004, vol. 2, pp. 1898-1903. (Pubitemid 40821664)
    • (2004) 2004 International Conference on Power System Technology, POWERCON 2004 , vol.2 , pp. 1898-1903
    • Sim, W.M.1    Chan, C.F.2
  • 8
    • 43549095745 scopus 로고    scopus 로고
    • A novel on-line monitoring device of stray current in dc rail transit systems
    • Oct. 22-26
    • Jinmin and M. Longhua, "A novel on-line monitoring device of stray current in dc rail transit systems," in Proc. Int. Conf. Power Syst. Technol., Oct. 22-26, 2006, pp. 1-4.
    • (2006) Proc. Int. Conf. Power Syst. Technol. , pp. 1-4
    • Jinmin1    Longhua, M.2
  • 9
    • 20544465426 scopus 로고    scopus 로고
    • Data logger apparatus for stray current measurement of subway and power line
    • TB7-53, IECON 2004 - 30th Annual Conference of IEEE Industrial Electronics Society
    • J.-H. Bae, Y.-C. Ha, T.-H. Ha, H.-G. Lee, D.-K. Kim, and J.-D. Lee, "Data logger apparatus for stray current measurement of subway and power line," in Proc. 30th Annu. Conf. IEEE Ind. Electron. Soc., Nov. 2-6, 2004, vol. 2, pp. 1563-1566. (Pubitemid 40845698)
    • (2004) IECON Proceedings (Industrial Electronics Conference) , vol.2 , pp. 1563-1566
    • Bae, J.-H.1    Ha, Y.-C.2    Ha, T.-H.3    Lee, H.-G.4    Kim, D.-K.5    Lee, J.-D.6
  • 10
    • 0034977736 scopus 로고    scopus 로고
    • Analysis of stray current, track-to-earth potentials &substation negative grounding in DC traction electrification system
    • K. D. Pham, R. S. Thomas, and W. E. Stinger, "Analysis of stray current, track-to-earth potentials and substation negative grounding in DC traction electrification system," in Proc. IEEE/ASME Joint Railroad Conf., Apr. 17-19, 2001, pp. 141-160. (Pubitemid 32535917)
    • (2001) Proceedings of the IEEE/ASME Joint Railroad Conference , pp. 141-160
    • Pham, K.D.1    Thomas, R.S.2    Stinger, W.E.3
  • 11
    • 17744364525 scopus 로고    scopus 로고
    • Evaluation of the maximum potential rise in Taipei rail transit systems
    • DOI 10.1109/TPWRD.2004.833902
    • C.-H. Lee, "Evaluation of the maximum potential rise in taipei rail transit systems," IEEE Trans. Power Del., vol. 20, no. 2, pt. 2, pp. 1379-1384, Apr. 2005. (Pubitemid 40573567)
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.2 , pp. 1379-1384
    • Lee, C.-H.1
  • 13
    • 78649575406 scopus 로고    scopus 로고
    • Effects of the DC stray currents on subway tunnel structures evaluated by FEManalysis
    • Minneapolis,MN, Jul. 25-29
    • M. Brenna, A. Dolara, S. Leva, and D. Zaninelli, "Effects of the DC stray currents on subway tunnel structures evaluated by FEManalysis," in Proc. IEEE Power Energy Soc. Gen.Meeting,Minneapolis,MN, Jul. 25-29, 2010, p. 7.
    • (2010) Proc. IEEE Power Energy Soc. Gen.Meeting , pp. 7
    • Brenna, M.1    Dolara, A.2    Leva, S.3    Zaninelli, D.4
  • 14
    • 84866728648 scopus 로고    scopus 로고
    • Railway Applications-Fixed Installations-Part 2: Protective Provisions Against The Effects of Stray Currents Caused By d.c. Traction Systems, Standard EN50122-2 1999
    • Railway Applications-Fixed Installations-Part 2: Protective Provisions Against The Effects of Stray Currents Caused By d.c. Traction Systems, Standard EN 50122-2, 1999.
  • 15
    • 78651360675 scopus 로고    scopus 로고
    • New stability analysis for tuning PI controller of power converters in railway application
    • Feb.
    • M. Brenna, F. Foiadelli, and D. Zaninelli, "New stability analysis for tuning PI controller of power converters in railway application," IEEE Trans. Ind. Electron., vol. 58, no. 2, pp. 533-543, Feb. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.2 , pp. 533-543
    • Brenna, M.1    Foiadelli, F.2    Zaninelli, D.3
  • 16
    • 77954003797 scopus 로고    scopus 로고
    • Analysis of rail potential and stray currents in a direct-current transit system
    • Jul.
    • T. Yii-Shen and L. Chien-Hsing, "Analysis of rail potential and stray currents in a direct-current transit system," IEEE Trans. Power Del., vol. 25, no. 3, pp. 1516-1525, Jul. 2010.
    • (2010) IEEE Trans. Power Del. , vol.25 , Issue.3 , pp. 1516-1525
    • Yii-Shen, T.1    Chien-Hsing, L.2
  • 17
    • 85047679014 scopus 로고    scopus 로고
    • Railway track transmission line parameters from finite element field modeling-Series impedance
    • Nov.
    • R. J. HiII, S. Brillante, and P. J. Leonard, "Railway track transmission line parameters from finite element field modeling-Series impedance," in Proc. Inst. Elect. Eng., Elect. Power Appl., Nov. 1999, vol. 146, no. 6.
    • (1999) Proc. Inst. Elect. Eng., Elect. Power Appl. , vol.146 , Issue.6
    • Hill, R.J.1    Brillante, S.2    Leonard, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.