메뉴 건너뛰기




Volumn 25, Issue 3, 2000, Pages 162-218

Echocardiographic assessment of prosthetic heart valves

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; COLOR ULTRASOUND FLOWMETRY; COST EFFECTIVENESS ANALYSIS; DIAGNOSTIC VALUE; FUNCTIONAL ASSESSMENT; HEART CATHETERIZATION; HEART LEFT VENTRICLE PERFORMANCE; HEART VALVE PROSTHESIS; HEMODYNAMICS; NUCLEAR MAGNETIC RESONANCE IMAGING; PROSTHESIS FAILURE; REVIEW; STRUCTURE ANALYSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; BIOPROSTHESIS; CORONARY ARTERY BLOOD FLOW; ECHOCARDIOGRAPHY; ENDOCARDITIS; EXERCISE TEST; FLUOROSCOPY; HEART VALVE; HEART VALVE REPLACEMENT; HUMAN; PHYSIOLOGY; POSTOPERATIVE COMPLICATION; PROSTHESIS; STENT; THREE DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84866683311     PISSN: 01462806     EISSN: None     Source Type: Journal    
DOI: 10.1067/mcd.2000.104056     Document Type: Review
Times cited : (7)

References (154)
  • 1
    • 0025997565 scopus 로고
    • Echocardiographic assessment of prosthetic valves
    • Nanda NC, Cooper JW, Mahan EF, Fan PH. Echocardiographic assessment of prosthetic valves. Circulation 1991;84(suppl 1):1228-1239.
    • (1991) Circulation , vol.84 , Issue.1 SUPPL. , pp. 1228-1239
    • Nanda, N.C.1    Cooper, J.W.2    Mahan, E.F.3    Fan, P.H.4
  • 2
    • 0026503380 scopus 로고
    • Echocardiographic assessment of prosthetic heart valves
    • Zabalgoitia M. Echocardiographic assessment of prosthetic heart valves. Curr Probl Cardiol 1992;17:267-325.
    • (1992) Curr Probl Cardiol , vol.17 , pp. 267-325
    • Zabalgoitia, M.1
  • 4
    • 0026537356 scopus 로고
    • Value and limitations of transesophageal echocardiography in evaluating prosthetic or bioprosthetic valve dysfunction
    • Herrera CJ, Chaudhry FA, Mehlman DJ, Mulhern KM, O'Rourke RA, Zabalgoitia M. Value and limitations of transesophageal echocardiography in evaluating prosthetic or bioprosthetic valve dysfunction. Am J Cardiol 1992;69:697-9.
    • (1992) Am J Cardiol , vol.69 , pp. 697-699
    • Herrera, C.J.1    Chaudhry, F.A.2    Mehlman, D.J.3    Mulhern, K.M.4    O'Rourke, R.A.5    Zabalgoitia, M.6
  • 7
    • 0026688859 scopus 로고
    • Regurgitant flow in cardiac valve prostheses: Diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography
    • Deutsch HJ, Bachmann R, Sechtem U, Curtius JM, Jungehulsing M, Schicha H, et al. Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography. J Am Coll Cardiol 1992;19:1500-7.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1500-1507
    • Deutsch, H.J.1    Bachmann, R.2    Sechtem, U.3    Curtius, J.M.4    Jungehulsing, M.5    Schicha, H.6
  • 10
    • 33748207077 scopus 로고
    • Mitral replacement: Clinical experience with a ball valve prosthesis
    • Starr A, Edwards M. Mitral replacement: clinical experience with a ball valve prosthesis. Ann Surg 1961;154:726-40.
    • (1961) Ann Surg , vol.154 , pp. 726-740
    • Starr, A.1    Edwards, M.2
  • 11
    • 0027075062 scopus 로고
    • Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves
    • Alton ME, Pasierski TJ, Orsinelli DA, Eaton GM, Pearson AC. Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves. J Am Coll Cardiol 1992;20:1503-11.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1503-1511
    • Alton, M.E.1    Pasierski, T.J.2    Orsinelli, D.A.3    Eaton, G.M.4    Pearson, A.C.5
  • 13
    • 0029821920 scopus 로고    scopus 로고
    • Aortic valve replacement in patients 50 years old or younger with the St. Jude Medical valve: 14 year experience
    • Tatoulis J, Chaiyaroj S, Smith JA. Aortic valve replacement in patients 50 years old or younger with the St. Jude Medical valve: 14 year experience. J Heart Valve Dis 1996;5:491-7.
    • (1996) J Heart Valve Dis , vol.5 , pp. 491-497
    • Tatoulis, J.1    Chaiyaroj, S.2    Smith, J.A.3
  • 19
    • 0028866554 scopus 로고
    • Long-term fol low up of 292 patients after valve replacement with the Omnicarbon prosthetic valves
    • Thevenet A, Albat B. Long-term fol low up of 292 patients after valve replacement with the Omnicarbon prosthetic valves. J Heart Valve Dis 1995;4:634-9.
    • (1995) J Heart Valve Dis , vol.4 , pp. 634-639
    • Thevenet, A.1    Albat, B.2
  • 20
    • 4244128612 scopus 로고    scopus 로고
    • Fifteen-year experience with the Medtronic-Hall valve prosthesis: A follow-up study of 1104 consecutive patients
    • Nitter-Hauge S, Abdelnoor M, Svennevig JL. Fifteen-year experience with the Medtronic-Hall valve prosthesis: a follow-up study of 1104 consecutive patients. Circulation 1996;94(suppl 11):105-8.
    • (1996) Circulation , vol.94 , Issue.11 SUPPL. , pp. 105-108
    • Nitter-Hauge, S.1    Abdelnoor, M.2    Svennevig, J.L.3
  • 21
    • 0017755058 scopus 로고
    • The gluteraldehyde treated heterograft valve. Some engineering observations
    • Thomson F, Barret-Boyes BG. The gluteraldehyde treated heterograft valve. Some engineering observations. J Thorac Cardiovasc Surg 1977;74:317-21.
    • (1977) J Thorac Cardiovasc Surg , vol.74 , pp. 317-321
    • Thomson, F.1    Barret-Boyes, B.G.2
  • 22
    • 0020437326 scopus 로고
    • Sudden death due to cuspal dehiscence of the Ionescu-Shiley valve in the mitral position
    • Gabbay S, Strom J, Frater R. Sudden death due to cuspal dehiscence of the Ionescu-Shiley valve in the mitral position. J Thoracic Cardiovasc Surg 1982;84:313-5.
    • (1982) J Thoracic Cardiovasc Surg , vol.84 , pp. 313-315
    • Gabbay, S.1    Strom, J.2    Frater, R.3
  • 24
    • 0021224164 scopus 로고
    • Normally and abnormally functioning left-sided porcine bioprosthetic valves after long-term implantation in patients: Distinct spectra of histologic and histochemical changes
    • Goffin YA, Deuvaert F, Wellens F, Leclerc JL, Kiehm JL, Primo GC. Normally and abnormally functioning left-sided porcine bioprosthetic valves after long-term implantation in patients: Distinct spectra of histologic and histochemical changes. J Am Coll Cardiol 1984;4:324-32.
    • (1984) J Am Coll Cardiol , vol.4 , pp. 324-332
    • Goffin, Y.A.1    Deuvaert, F.2    Wellens, F.3    Leclerc, J.L.4    Kiehm, J.L.5    Primo, G.C.6
  • 27
    • 0019471666 scopus 로고
    • Five to eight year follow-up of patients undergoing porcine heart valve replacement
    • Cohn LH, Mudge GH, Pratter F, Collins JJ. Five to eight year follow-up of patients undergoing porcine heart valve replacement. N Engl J Med 1981;304:258-62.
    • (1981) N Engl J Med , vol.304 , pp. 258-262
    • Cohn, L.H.1    Mudge, G.H.2    Pratter, F.3    Collins, J.J.4
  • 28
    • 0021354971 scopus 로고
    • Degeneration of porcine bioprosthetic cardiac valves: Incidence of primary tissue failures among 938 bioprostheses at risk
    • Gallo I, Ruiz B, Nistal F, Duran CM. Degeneration of porcine bioprosthetic cardiac valves: incidence of primary tissue failures among 938 bioprostheses at risk. Am J Cardiol 1984;53:1061-5.
    • (1984) Am J Cardiol , vol.53 , pp. 1061-1065
    • Gallo, I.1    Ruiz, B.2    Nistal, F.3    Duran, C.M.4
  • 29
    • 0002450621 scopus 로고
    • Pathology of bioprostheses and other tissue heart valve replacements
    • Silver MD, editor. New York: Churchill Livingstone
    • Schoen FJ. Pathology of bioprostheses and other tissue heart valve replacements. In Silver MD, editor. Cardiovascular Pathology. New York: Churchill Livingstone; 1991. p. 1547-606.
    • (1991) Cardiovascular Pathology , pp. 1547-1606
    • Schoen, F.J.1
  • 31
    • 0019393545 scopus 로고
    • Porcine valve durability in children
    • Dunn JM. Porcine valve durability in children. Ann Thorac Surg 1981;32:357-68.
    • (1981) Ann Thorac Surg , vol.32 , pp. 357-368
    • Dunn, J.M.1
  • 33
    • 0025254212 scopus 로고
    • Tenyear experience with the porcine bioprosthetic valve: Interrelationship of valve survival and patient survival in 1,050 valve replacements
    • Jones EL, Weintraub WS, Craver JM, Guyton RA, Cohen CL, Corrigan, et al. Tenyear experience with the porcine bioprosthetic valve: interrelationship of valve survival and patient survival in 1,050 valve replacements. Ann Thorac Surg 1990;49:370-84.
    • (1990) Ann Thorac Surg , vol.49 , pp. 370-384
    • Jones, E.L.1    Weintraub, W.S.2    Craver, J.M.3    Guyton, R.A.4    Cohen, C.L.5    Corrigan6
  • 34
    • 0024444814 scopus 로고
    • Fifteen-year experience with 1678 Hancock porcine bioprosthetic heart valve replacements
    • Cohn LH, Collins JJ, Disesa VJ, Couper GS, Peigh PS, Kowalker W, et al. Fifteen-year experience with 1678 Hancock porcine bioprosthetic heart valve replacements. Ann Surg 1989;210:435-43.
    • (1989) Ann Surg , vol.210 , pp. 435-443
    • Cohn, L.H.1    Collins, J.J.2    Disesa, V.J.3    Couper, G.S.4    Peigh, P.S.5    Kowalker, W.6
  • 35
    • 0026942532 scopus 로고
    • Aortic valve replacement with the Toronto SPV bioprosthesis
    • David TE, Bos J, Rakowski H. Aortic valve replacement with the Toronto SPV bioprosthesis. J Heart Valve Dis 1992;1:244-8.
    • (1992) J Heart Valve Dis , vol.1 , pp. 244-248
    • David, T.E.1    Bos, J.2    Rakowski, H.3
  • 36
    • 0024237524 scopus 로고
    • Aortic valve replacement with stentless porcine bioprosthesis
    • David TE, Ropchan GC, Butany JW. Aortic valve replacement with stentless porcine bioprosthesis. J Card Surg 1988;3:501-5.
    • (1988) J Card Surg , vol.3 , pp. 501-505
    • David, T.E.1    Ropchan, G.C.2    Butany, J.W.3
  • 37
    • 0028906949 scopus 로고
    • Comparison of implantation techniques using Freestyle stentless porcine aortic valve
    • Kon ND, Westaby S, Amarasena N, Rliai R, Cordell AR. Comparison of implantation techniques using Freestyle stentless porcine aortic valve. Ann Thorac Surg 1995;59:857-62.
    • (1995) Ann Thorac Surg , vol.59 , pp. 857-862
    • Kon, N.D.1    Westaby, S.2    Amarasena, N.3    Rliai, R.4    Cordell, A.R.5
  • 38
    • 0029554998 scopus 로고
    • Time-related hemodynamic changes after aortic valve replacement with the Freestyle stentless xenograft
    • Westaby S, Amarasena N, Long V, Prothero A, Amarasena GA, Banning AR et al. Time-related hemodynamic changes after aortic valve replacement with the Freestyle stentless xenograft. Ann Thorac Surg 1995;60:1633-8.
    • (1995) Ann Thorac Surg , vol.60 , pp. 1633-1638
    • Westaby, S.1    Amarasena, N.2    Long, V.3    Prothero, A.4    Amarasena, G.A.5    Banning, A.R.6
  • 40
    • 0028024747 scopus 로고
    • Hydrodynamic performance of the Medronic Freestyle aortic root bioprosthesis
    • Yoganathan AP, Eberhardt CE, Walker PG. Hydrodynamic performance of the Medronic Freestyle aortic root bioprosthesis. J Heart Valve Dis 1994;3:571-80.
    • (1994) J Heart Valve Dis , vol.3 , pp. 571-580
    • Yoganathan, A.P.1    Eberhardt, C.E.2    Walker, P.G.3
  • 41
    • 0029112448 scopus 로고
    • Composite stentless xenograft for aortic valve replacement: Clinical evaluation of function
    • O'Brien MF. Composite stentless xenograft for aortic valve replacement: clinical evaluation of function. Ann Thorac Surg 1995;60(suppl 2):S406-S409.
    • (1995) Ann Thorac Surg , vol.60 , Issue.2 SUPPL.
    • O'Brien, M.F.1
  • 42
    • 0029091204 scopus 로고
    • The Cryolife-O'Brien composite aortic stentless xenograft: Surgical technique of implantation
    • O'Brien MF. The Cryolife-O'Brien composite aortic stentless xenograft: surgical technique of implantation. Ann Thorac Surg 1995;60(suupl 2):S410-S413.
    • (1995) Ann Thorac Surg , vol.60 , Issue.2 SUUPL
    • O'Brien, M.F.1
  • 44
    • 0029080237 scopus 로고
    • Aortic valve replacement with a stentless porcine bioprosthesis: Multicentretrial. Canadian investigators of the Toronto SPV valve trial
    • del Rizzo DF, Goldman BS, David TE. Aortic valve replacement with a stentless porcine bioprosthesis: multicentretrial. Canadian investigators of the Toronto SPV valve trial. Can J Cardiol 1995;11:597-603.
    • (1995) Can J Cardiol , vol.11 , pp. 597-603
    • Del Rizzo, D.F.1    Goldman, B.S.2    David, T.E.3
  • 45
    • 0029093740 scopus 로고
    • Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position
    • Jin XY, Gibson DG, Yacoub MH, Pepper JR. Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position. Ann Thorac Surg 1995;60(suppl 2):S395-S401.
    • (1995) Ann Thorac Surg , vol.60 , Issue.2 SUPPL.
    • Jin, X.Y.1    Gibson, D.G.2    Yacoub, M.H.3    Pepper, J.R.4
  • 47
    • 0029872074 scopus 로고    scopus 로고
    • Hemodynamic performance of the PRIMA Edwards stentless aortic xenograft: Early results of a multicenter clinical trial
    • Dossche K, Vanermen H, Daenen W, Pillai R, Konertz W. Hemodynamic performance of the PRIMA Edwards stentless aortic xenograft: Early results of a multicenter clinical trial. Thorac Cardiovasc Surg 1996;44:11-4.
    • (1996) Thorac Cardiovasc Surg , vol.44 , pp. 11-14
    • Dossche, K.1    Vanermen, H.2    Daenen, W.3    Pillai, R.4    Konertz, W.5
  • 49
    • 0026333714 scopus 로고
    • Pulmonary autograft aortic valve replacement: Long term results
    • Ross D, Jackson M, Davies J. Pulmonary autograft aortic valve replacement: long term results. J Cardiovasc Surg 1991;6(suppl 4):529-33.
    • (1991) J Cardiovasc Surg , vol.6 , Issue.4 SUPPL. , pp. 529-533
    • Ross, D.1    Jackson, M.2    Davies, J.3
  • 50
    • 0003030017 scopus 로고
    • Homograft aortic valve replacement in aortic incompetence and stenosis
    • Barratt-Boyes B. Homograft aortic valve replacement in aortic incompetence and stenosis. Thorax 1964;19:131-5.
    • (1964) Thorax , vol.19 , pp. 131-135
    • Barratt-Boyes, B.1
  • 51
    • 0017346412 scopus 로고
    • Six-year review of the results of freehand aortic valve replacement using an antiobiotic sterilized homograft valve
    • Barrat-Boyes BG, RocheAH, Whitlock RM. Six-year review of the results of freehand aortic valve replacement using an antiobiotic sterilized homograft valve. Circulation 1977;55:353-61.
    • (1977) Circulation , vol.55 , pp. 353-361
    • Barrat-Boyes, B.G.1    Roche, A.H.2    Whitlock, R.M.3
  • 53
    • 0014192811 scopus 로고
    • Replacement of aortic and mitral valves with a pulmonary autograft
    • Ross DN. Replacement of aortic and mitral valves with a pulmonary autograft. Lancet 1967;2:956-8.
    • (1967) Lancet , vol.2 , pp. 956-958
    • Ross, D.N.1
  • 54
    • 0021953792 scopus 로고
    • Long-term assessment of aortic valve replacement with autologous pulmonary valve
    • Robles A, Vaughan M, Lau JK, Bodnar E, Ross DN. Long-term assessment of aortic valve replacement with autologous pulmonary valve. Ann Thorac Surg 1985; 39:238-42.
    • (1985) Ann Thorac Surg , vol.39 , pp. 238-242
    • Robles, A.1    Vaughan, M.2    Lau, J.K.3    Bodnar, E.4    Ross, D.N.5
  • 56
    • 0018866203 scopus 로고
    • Long-term performance of homograft and autograft valves
    • Bodnar E, Wain WH, Martelli V, Ross DN. Long-term performance of homograft and autograft valves. Artif Organs 1980;4:20-3.
    • (1980) Artif Organs , vol.4 , pp. 20-23
    • Bodnar, E.1    Wain, W.H.2    Martelli, V.3    Ross, D.N.4
  • 57
    • 0030219336 scopus 로고    scopus 로고
    • Pulmonary autograft reoperation: Incidence and management
    • Elkins RC, Lane MM, McCue C. Pulmonary autograft reoperation: incidence and management. Ann Thorac Surg 1996;62:450-5.
    • (1996) Ann Thorac Surg , vol.62 , pp. 450-455
    • Elkins, R.C.1    Lane, M.M.2    McCue, C.3
  • 58
    • 0024466667 scopus 로고
    • Continuous wave Doppler echocardiographic measurements of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study
    • Burstow DJ, Nishimura RA, Bailey KR, Reeder GS, HolmesDR Jr, Seward JB, et al. Continuous wave Doppler echocardiographic measurements of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study. Circulation 1989;80:504-14.
    • (1989) Circulation , vol.80 , pp. 504-514
    • Burstow, D.J.1    Nishimura, R.A.2    Bailey, K.R.3    Reeder, G.S.4    Holmes Jr., D.R.5    Seward, J.B.6
  • 59
    • 0022499426 scopus 로고
    • Validation of continuous-wave Doppler echocardiographic measurements of mitral and tri cuspid prosthetic valve gradients: A simultaneous Doppler-catheter study
    • Wlkins GT, Gillam LD, Kritzer GL, Levine RA, Palacios IF, Weyman AE. Validation of continuous-wave Doppler echocardiographic measurements of mitral and tri cuspid prosthetic valve gradients: a simultaneous Doppler-catheter study. Circulation 1986;74:786-95.
    • (1986) Circulation , vol.74 , pp. 786-795
    • Wlkins, G.T.1    Gillam, L.D.2    Kritzer, G.L.3    Levine, R.A.4    Palacios, I.F.5    Weyman, A.E.6
  • 60
    • 0025829875 scopus 로고
    • Effects of exercise on transmitral gradient and pulmonary artery pressure in patients with mitral stenosis or a prosthetic mitral valve: A Doppler echocardiographic study
    • Leavitt JI, Coats MH, Falk RH. Effects of exercise on transmitral gradient and pulmonary artery pressure in patients with mitral stenosis or a prosthetic mitral valve: a Doppler echocardiographic study. J Am Coll Cardiol 1991;17:1520-6.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1520-1526
    • Leavitt, J.I.1    Coats, M.H.2    Falk, R.H.3
  • 61
    • 0026533821 scopus 로고
    • Value of exercise Doppler echocardiography in patients with prosthetic or bioprosthetic cardiac valves
    • van den Brink RB, Verheul HA, Visser CA, Koelemay MJ, Dunning AJ. Value of exercise Doppler echocardiography in patients with prosthetic or bioprosthetic cardiac valves. Am J Cardiol 1992;69:367-72.
    • (1992) Am J Cardiol , vol.69 , pp. 367-372
    • Van Den Brink, R.B.1    Verheul, H.A.2    Visser, C.A.3    Koelemay, M.J.4    Dunning, A.J.5
  • 62
    • 0025820710 scopus 로고
    • Errors in pressure gradient measurement by continuous wave Doppler ultrasound: Type, size and age effects in bioprosthetic aortic valves
    • Stewart SFC, Nast ER, Arabia FA, Talbot TL, Proschan M, Clark RE. Errors in pressure gradient measurement by continuous wave Doppler ultrasound: type, size and age effects in bioprosthetic aortic valves. J Am Coll Cardiol 1991;18:769-79.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 769-779
    • Stewart, S.F.C.1    Nast, E.R.2    Arabia, F.A.3    Talbot, T.L.4    Proschan, M.5    Clark, R.E.6
  • 63
    • 0029845424 scopus 로고    scopus 로고
    • Turbulant/viscous interactions control Doppler/catheter pressure discrepancies in aortic stenosis
    • Cape EG, Jones M, Yamada I, Van Auker MD, Valdes-Cruz LM. Turbulant/viscous interactions control Doppler/catheter pressure discrepancies in aortic stenosis. Circulation 1996;94:2975-81.
    • (1996) Circulation , vol.94 , pp. 2975-2981
    • Cape, E.G.1    Jones, M.2    Yamada, I.3    Van Auker, M.D.4    Valdes-Cruz, L.M.5
  • 65
    • 0027070923 scopus 로고
    • Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow mode
    • Voelker W, Reul H, Stelzer T, Schmidt A, Karsch KR. Pressure recovery in aortic stenosis: an in vitro study in a pulsatile flow mode. J Am Coll Cardiol 1992; 20:1585-93.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1585-1593
    • Voelker, W.1    Reul, H.2    Stelzer, T.3    Schmidt, A.4    Karsch, K.R.5
  • 66
    • 0030294111 scopus 로고    scopus 로고
    • Is pressure recovery an important cause of "Doppler aortic stenosis" with no gradient at cardiac catheterization?
    • Chambers JB. Is pressure recovery an important cause of "Doppler aortic stenosis" with no gradient at cardiac catheterization? Heart 1996:76;381-3.
    • (1996) Heart , vol.76 , pp. 381-383
    • Chambers, J.B.1
  • 67
    • 0025346848 scopus 로고
    • Determination of aortic valve area by two-dimensional and Doppler echocardiography in patients with normal and stenostic bioprosthetic valves
    • Rothbart RM, Castriz JL, Harding LV, Russo CD, Teague SM. Determination of aortic valve area by two-dimensional and Doppler echocardiography in patients with normal and stenostic bioprosthetic valves. J Am Coll Cardiol 1990;15: 817-24.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 817-824
    • Rothbart, R.M.1    Castriz, J.L.2    Harding, L.V.3    Russo, C.D.4    Teague, S.M.5
  • 68
    • 0025179228 scopus 로고
    • Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990;16:637-43.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 637-643
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 69
    • 0024535070 scopus 로고
    • The Gorlin formula validated against directly observed orifice area in porcine mitral bioprostheses
    • Chambers JB, Cochrane T, Black MM, Jackson G. The Gorlin formula validated against directly observed orifice area in porcine mitral bioprostheses. J Am Coll Cardiol 1989;13:1561-71.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1561-1571
    • Chambers, J.B.1    Cochrane, T.2    Black, M.M.3    Jackson, G.4
  • 70
    • 0026026862 scopus 로고
    • Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation
    • Chafizadeh ER, Zoghbi WA. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation 1991;83:213-23.
    • (1991) Circulation , vol.83 , pp. 213-223
    • Chafizadeh, E.R.1    Zoghbi, W.A.2
  • 71
    • 0026512411 scopus 로고
    • Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in-vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves
    • Baumgartner H, Khan S, DeRobertisM, Czer L, Maurer G. Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: an in-vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. J Am Coll Cardiol 1992;19:324-32.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 324-332
    • Baumgartner, H.1    Khan, S.2    DeRobertis, M.3    Czer, L.4    Maurer, G.5
  • 73
    • 0025341168 scopus 로고
    • Validation and applications of mitral prosthetic valvular areas by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of mitral prosthetic valvular areas by Doppler echocardiography. Am J Cardiol 1990;65:1443-8.
    • (1990) Am J Cardiol , vol.65 , pp. 1443-1448
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 74
    • 0028158512 scopus 로고
    • Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis
    • Burwash IG, Thomas DD, Sadahiro M, Pearlman AS, Verrier ED, ThomasR, et al. Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis. Circulation 1994;89: 827-35.
    • (1994) Circulation , vol.89 , pp. 827-835
    • Burwash, I.G.1    Thomas, D.D.2    Sadahiro, M.3    Pearlman, A.S.4    Verrier, E.D.5    Thomas, R.6
  • 75
    • 0030667656 scopus 로고    scopus 로고
    • Application of the continuity equation and valve resistance to the evaluation of St. Jude medical prosthetic aortic valve dysfunction
    • Saad RM, Barbetseas J, Olmos L, Rubio N, Zogbhi WA. Application of the continuity equation and valve resistance to the evaluation of St. Jude medical prosthetic aortic valve dysfunction. Am J Cardiol 1997;80:1239-42.
    • (1997) Am J Cardiol , vol.80 , pp. 1239-1242
    • Saad, R.M.1    Barbetseas, J.2    Olmos, L.3    Rubio, N.4    Zogbhi, W.A.5
  • 76
    • 0025044621 scopus 로고
    • Hemodynamic resistance as a measure of functional impairment in aortic valvular stenosis
    • Ford LE, Feldman T, Chiu YC, Carroll JD. Hemodynamic resistance as a measure of functional impairment in aortic valvular stenosis. Cire Res 1990;66:1-7.
    • (1990) Cire Res , vol.66 , pp. 1-7
    • Ford, L.E.1    Feldman, T.2    Chiu, Y.C.3    Carroll, J.D.4
  • 77
    • 0027092693 scopus 로고
    • Aortic valve resistance as an adjunct to the Gorlin formula in assessing the severity of aortic stenosis in symptomatic patients
    • Cannon JD, Zile MR, Crawford FA, Carabello BA. Aortic valve resistance as an adjunct to the Gorlin formula in assessing the severity of aortic stenosis in symptomatic patients. J Am Coll Cardiol 1992;20:1517-23.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1517-1523
    • Cannon, J.D.1    Zile, M.R.2    Crawford, F.A.3    Carabello, B.A.4
  • 79
    • 0024312662 scopus 로고
    • Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function
    • Kapur KK, Fan P, Nanda NC, Yoganathan AP, Goyal RG. Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function. J Am Coll Cardiol 1989;13:1561-71.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1561-1571
    • Kapur, K.K.1    Fan, P.2    Nanda, N.C.3    Yoganathan, A.P.4    Goyal, R.G.5
  • 80
    • 0025341168 scopus 로고
    • Validation and application of mitral prosthetic valvular areas calculated by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and application of mitral prosthetic valvular areas calculated by Doppler echocardiography. Am J Cardiol 1990;65:1443-8.
    • (1990) Am J Cardiol , vol.65 , pp. 1443-1448
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 81
    • 0026484494 scopus 로고
    • Comparison of transesophageal color flow Doppler imaging of normal mitral regurgitant jets in St. Jude Medical and Medtronic-Hall prostheses
    • Hixson CS, Smith MD, Mattson MD, Moris EJ, Lenhoff SJ, Salley RK. Comparison of transesophageal color flow Doppler imaging of normal mitral regurgitant jets in St. Jude Medical and Medtronic-Hall prostheses. J Am Soc Echocardiogr 1992;5:57-62.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 57-62
    • Hixson, C.S.1    Smith, M.D.2    Mattson, M.D.3    Moris, E.J.4    Lenhoff, S.J.5    Salley, R.K.6
  • 82
    • 0025822673 scopus 로고
    • Transesophageal color Doppler echocardiography of the normal St Jude Medical mitral valve prosthesis
    • Lange HW, Olson JD, Pederson WR, Kane MA, Daniel JA, Mooney MR, et al. Transesophageal color Doppler echocardiography of the normal St Jude Medical mitral valve prosthesis. Am Heart J 1991;122:489-94.
    • (1991) Am Heart J , vol.122 , pp. 489-494
    • Lange, H.W.1    Olson, J.D.2    Pederson, W.R.3    Kane, M.A.4    Daniel, J.A.5    Mooney, M.R.6
  • 83
    • 0027411028 scopus 로고
    • Pitfalls in the echo-Doppler diagnosis of prosthetic valve disorders
    • Zabalgoitia M, Garcia M. Pitfalls in the echo-Doppler diagnosis of prosthetic valve disorders. Echocardiography 1993;10:203-12.
    • (1993) Echocardiography , vol.10 , pp. 203-212
    • Zabalgoitia, M.1    Garcia, M.2
  • 85
    • 0028436941 scopus 로고
    • Measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle
    • Baldwin JT, Deutsch S, Geselowitz DB, Tarbell JM. Measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle. J Biomech Eng 1994;116:190-200.
    • (1994) J Biomech Eng , vol.116 , pp. 190-200
    • Baldwin, J.T.1    Deutsch, S.2    Geselowitz, D.B.3    Tarbell, J.M.4
  • 86
    • 12944285634 scopus 로고
    • In vitro steady leakagejet formation of technical heart valve prostheses: A photo video optical and color Doppler study
    • Liepschs D, editor. Munich: VDI-Verlag GmbH
    • Kohler J, Wirtz R, Fehske W. In vitro steady leakagejet formation of technical heart valve prostheses: a photo video optical and color Doppler study. In Liepschs D, editor. Third International Symposium on Biofluid Mechanics. Munich: VDI-Verlag GmbH; 1994. p. 315-23.
    • (1994) Third International Symposium on Biofluid Mechanics , pp. 315-323
    • Kohler, J.1    Wirtz, R.2    Fehske, W.3
  • 87
    • 0027499532 scopus 로고
    • Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve
    • Chambers J, Cross J, Deverall P, Sowton E. Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve. J Am Coll Cardiol 1993;21: 398-405.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 398-405
    • Chambers, J.1    Cross, J.2    Deverall, P.3    Sowton, E.4
  • 88
    • 0024002897 scopus 로고
    • Normal values of prosthetic valve Doppler echocardiographic parameters: A review
    • Reisner SA, Maltzer RS. Normal values of prosthetic valve Doppler echocardiographic parameters: a review. J Am Soc Echocardiogr 1988;1:201-10.
    • (1988) J Am Soc Echocardiogr , vol.1 , pp. 201-210
    • Reisner, S.A.1    Maltzer, R.S.2
  • 89
    • 0026465941 scopus 로고
    • The stentless bioprosthesis: Surgical challenges and implications for long-term durability
    • Barratt Boyes BG, Christie GW, Raudkivi PJ. The stentless bioprosthesis: surgical challenges and implications for long-term durability. Eur J Cardiothorac Surg 1992;6(suppl 1):S39-S42.
    • (1992) Eur J Cardiothorac Surg , vol.6 , Issue.1 SUPPL.
    • Barratt Boyes, B.G.1    Christie, G.W.2    Raudkivi, P.J.3
  • 91
    • 0030449514 scopus 로고    scopus 로고
    • Effects of incoordination on left ventricular forcevelocity relation in aortic stenosis
    • Jin XY, Pepper JR, Gibson DG. Effects of incoordination on left ventricular forcevelocity relation in aortic stenosis. Heart 1996;76:495-501.
    • (1996) Heart , vol.76 , pp. 495-501
    • Jin, X.Y.1    Pepper, J.R.2    Gibson, D.G.3
  • 93
    • 0023127005 scopus 로고
    • Long-term follow-up of patients with the antibiotic-sterilized aortic homograft valve inserted freehand in the aortic position
    • Barrat-Boyes BG, Roche AH, Subramanyan RS, Pemberton JR, Whitlock RM. Long-term follow-up of patients with the antibiotic-sterilized aortic homograft valve inserted freehand in the aortic position. Circulation 1987;75:768-77.
    • (1987) Circulation , vol.75 , pp. 768-777
    • Barrat-Boyes, B.G.1    Roche, A.H.2    Subramanyan, R.S.3    Pemberton, J.R.4    Whitlock, R.M.5
  • 94
    • 0024466667 scopus 로고
    • Continuous wave Doppler echocardiograpic measurement of prosthetic valve gradients. Simultaneous Doppler-catheter correlative study
    • Burstow DJ, Nishimura RA, Bailey KR, Reeder GS, Seward JB, Tajik AJ. Continuous wave Doppler echocardiograpic measurement of prosthetic valve gradients. Simultaneous Doppler-catheter correlative study. Circulation 1989;80: 504-14.
    • (1989) Circulation , vol.80 , pp. 504-514
    • Burstow, D.J.1    Nishimura, R.A.2    Bailey, K.R.3    Reeder, G.S.4    Seward, J.B.5    Tajik, A.J.6
  • 95
    • 0026026862 scopus 로고
    • Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation
    • Chafizadeh ER, Zoghbi WA. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation 1991;83:213-23.
    • (1991) Circulation , vol.83 , pp. 213-223
    • Chafizadeh, E.R.1    Zoghbi, W.A.2
  • 96
    • 12944286060 scopus 로고
    • Application of the continuity equation to the evaluation of St Jude prosthetic aortic valve dysfunction
    • Saad RM, Olmos L, Rubio N, Zoghbi WA. Application of the continuity equation to the evaluation of St Jude prosthetic aortic valve dysfunction [abstract]. Circulation 1994;90:1-115.
    • (1994) Circulation , vol.90 , pp. 1-115
    • Saad, R.M.1    Olmos, L.2    Rubio, N.3    Zoghbi, W.A.4
  • 97
    • 0026459764 scopus 로고
    • Spontaneous echocardiographic contrast with the Carbomedics mitral valve prosthesis
    • Reisner SA, Rinkevich D, Markiewicz W, Alder Z, Milo S. Spontaneous echocardiographic contrast with the Carbomedics mitral valve prosthesis. Am J Cardiol 1992;70:1497-9.
    • (1992) Am J Cardiol , vol.70 , pp. 1497-1499
    • Reisner, S.A.1    Rinkevich, D.2    Markiewicz, W.3    Alder, Z.4    Milo, S.5
  • 98
    • 0019988197 scopus 로고
    • Percutaneous balloon valvuloplasty: A new method for treating congenital pulmonary valve stenosis
    • Kan JS, White RJ, Mitchell SE. Percutaneous balloon valvuloplasty: a new method for treating congenital pulmonary valve stenosis. N Engl J Med 1982;307:540-2.
    • (1982) N Engl J Med , vol.307 , pp. 540-542
    • Kan, J.S.1    White, R.J.2    Mitchell, S.E.3
  • 99
    • 0022576922 scopus 로고
    • Late ball variance with the mode 1000 Starr-Edwards aortic valve prosthesis: Risk analysis and strategy of operative management
    • Grunkemeier GL, Starr A. Late ball variance with the mode 1000 Starr-Edwards aortic valve prosthesis: risk analysis and strategy of operative management. J Thorac Cardiovasc Surg 1986;91:918-23.
    • (1986) J Thorac Cardiovasc Surg , vol.91 , pp. 918-923
    • Grunkemeier, G.L.1    Starr, A.2
  • 101
    • 0021336390 scopus 로고
    • Echocardiography of porcine aortic prosthesis with flail leaflets due to degeneration and calcification
    • Bansal RC, Morrison DL, Jacobson JG. Echocardiography of porcine aortic prosthesis with flail leaflets due to degeneration and calcification. Am Heart J 1984;107:591-3.
    • (1984) Am Heart J , vol.107 , pp. 591-593
    • Bansal, R.C.1    Morrison, D.L.2    Jacobson, J.G.3
  • 102
    • 0019986179 scopus 로고
    • Calcification of porcine prosthetic heart valves: A radiographie and light microscopic study
    • Cipriano PR, Billingham ME, Oyer PE, Kutsche LM, Stinson EB. Calcification of porcine prosthetic heart valves: a radiographie and light microscopic study. Circulation 1982;66:1100-4.
    • (1982) Circulation , vol.66 , pp. 1100-1104
    • Cipriano, P.R.1    Billingham, M.E.2    Oyer, P.E.3    Kutsche, L.M.4    Stinson, E.B.5
  • 103
    • 0023637778 scopus 로고
    • Doppler and echocardiographic features of normal and dysfunctioning bioprosthetic valves
    • Alam M, Rosman HS, Lakier JB, Kemp S, Khaja F, Hautamaki K, et al. Doppler and echocardiographic features of normal and dysfunctioning bioprosthetic valves. J Am Coll Cardiol 1987;10:851-8.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 851-858
    • Alam, M.1    Rosman, H.S.2    Lakier, J.B.3    Kemp, S.4    Khaja, F.5    Hautamaki, K.6
  • 104
    • 0023191462 scopus 로고
    • Doppler echocardiographic appearance of cusp tears in tissue valve prostheses
    • Chambers JB, Monaghan MJ, Jackson G, Jewitt DE. Doppler echocardiographic appearance of cusp tears in tissue valve prostheses. J Am Coll Cardiol 1987; 10:462-6.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 462-466
    • Chambers, J.B.1    Monaghan, M.J.2    Jackson, G.3    Jewitt, D.E.4
  • 105
    • 0022485573 scopus 로고
    • Cooing intracardiac sound in a perforated porcine mitral valve detected by pulsed Doppler echocardiography
    • Kinney EL, Machado H, Cortada X. Cooing intracardiac sound in a perforated porcine mitral valve detected by pulsed Doppler echocardiography. Am Heart J 1986;112:420-3.
    • (1986) Am Heart J , vol.112 , pp. 420-423
    • Kinney, E.L.1    Machado, H.2    Cortada, X.3
  • 106
    • 0020571098 scopus 로고
    • Two-dimensional echocardiographic assessment of bioprosthetic valve dysfunction and infective endocarditis
    • Effron MK, Popp RL. Two-dimensional echocardiographic assessment of bioprosthetic valve dysfunction and infective endocarditis. J Am Coll Cardiol 1983; 2:597-606.
    • (1983) J Am Coll Cardiol , vol.2 , pp. 597-606
    • Effron, M.K.1    Popp, R.L.2
  • 107
    • 0023032960 scopus 로고
    • Detection of thrombotic obstruction of a Bjork-Shiley prosthesis by Doppler echocardiography
    • Barzilai B, Eisen HJ, Saffitz JE, Perez JE. Detection of thrombotic obstruction of a Bjork-Shiley prosthesis by Doppler echocardiography. Am Heart J 1988; 112:1088-90.
    • (1988) Am Heart J , vol.112 , pp. 1088-1090
    • Barzilai, B.1    Eisen, H.J.2    Saffitz, J.E.3    Perez, J.E.4
  • 108
    • 0025824446 scopus 로고
    • Transesophageal echocardiography in the diagnosis of mitral bioprosthetic obstruction
    • Lanzieri M, Michaelson S, Cohen IS. Transesophageal echocardiography in the diagnosis of mitral bioprosthetic obstruction. Crit Care Med 1991;19:979-81.
    • (1991) Crit Care Med , vol.19 , pp. 979-981
    • Lanzieri, M.1    Michaelson, S.2    Cohen, I.S.3
  • 109
    • 0026002353 scopus 로고
    • Role of transesophageal echocardiography in the diagnosis and management of prosthetic valve thrombosis
    • Dzavik V, Cohen G, Chan KL. Role of transesophageal echocardiography in the diagnosis and management of prosthetic valve thrombosis. J Am Coll Cardiol 1991;18:1829-33.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1829-1833
    • Dzavik, V.1    Cohen, G.2    Chan, K.L.3
  • 110
    • 0026823446 scopus 로고
    • Use of transesophageal echocardiography during thrombolysis with tissue plasminogen activator of a thrombosed prosthetic mitral valve
    • Young E, Shapiro SM, French WJ, Ginzton LE. Use of transesophageal echocardiography during thrombolysis with tissue plasminogen activator of a thrombosed prosthetic mitral valve. J Am Soc Echocardiogr 1992;5:153-8.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 153-158
    • Young, E.1    Shapiro, S.M.2    French, W.J.3    Ginzton, L.E.4
  • 111
    • 0023918491 scopus 로고
    • The risks and benefits of thrombolytic therapy in acute aortic and mitral prosthetic valve dysfunction
    • Graver M L, Galber PM, Tyras DH. The risks and benefits of thrombolytic therapy in acute aortic and mitral prosthetic valve dysfunction. Ann Thorac Surg 1988;46:85-8.
    • (1988) Ann Thorac Surg , vol.46 , pp. 85-88
    • Graver, M.L.1    Galber, P.M.2    Tyras, D.H.3
  • 117
    • 0023183916 scopus 로고
    • Thrombolytic treatment of acute thrombotic obstruction with disk valve prostheses: Experience with 26 cases
    • Lorient Roudaut MF, Ledain L, Roudaut R, Boisseau MR. Thrombolytic treatment of acute thrombotic obstruction with disk valve prostheses: experience with 26 cases. Semin Thromb Haemost 1987;13:201-5.
    • (1987) Semin Thromb Haemost , vol.13 , pp. 201-205
    • Lorient Roudaut, M.F.1    Ledain, L.2    Roudaut, R.3    Boisseau, M.R.4
  • 118
    • 0026024462 scopus 로고
    • Twelve-year comparison of a Bjork-Shiley mechanical heart with a porcine bioprosthesis
    • Bloomfield P, Wheatley DJ, Prescott RJ, Miller HC. Twelve-year comparison of a Bjork-Shiley mechanical heart with a porcine bioprosthesis. N Engl J Med 1991; 324:573-9.
    • (1991) N Engl J Med , vol.324 , pp. 573-579
    • Bloomfield, P.1    Wheatley, D.J.2    Prescott, R.J.3    Miller, H.C.4
  • 119
    • 0027957312 scopus 로고
    • Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses
    • Cannegieter SC, Rosendaal FR, Briet E. Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses. Circulation 1994; 89:635-641.
    • (1994) Circulation , vol.89 , pp. 635-641
    • Cannegieter, S.C.1    Rosendaal, F.R.2    Briet, E.3
  • 120
    • 0023616376 scopus 로고
    • Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis: Initial 5 year results of a randomized trial
    • Hammermaster KE, Henderson WG, Burchfiel CM, Sethi GK, Souchek J, Oprian C, et al. Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis: initial 5 year results of a randomized trial. J Am Coll Cardiol 1987;10:719-32.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 719-732
    • Hammermaster, K.E.1    Henderson, W.G.2    Burchfiel, C.M.3    Sethi, G.K.4    Souchek, J.5    Oprian, C.6
  • 121
    • 0026774730 scopus 로고
    • Mobile strands are frequently attached to the St. Jude Medical mitral valve prosthesis as assessed by two-dimensional transesophageal echocardiography
    • Stoddard MF, Dawkins PR, Longaker RA. Mobile strands are frequently attached to the St. Jude Medical mitral valve prosthesis as assessed by two-dimensional transesophageal echocardiography. Am Heart J 1992;124:671-4.
    • (1992) Am Heart J , vol.124 , pp. 671-674
    • Stoddard, M.F.1    Dawkins, P.R.2    Longaker, R.A.3
  • 122
    • 0028543888 scopus 로고
    • Detection of fibrous strands on prosthetic mitral valves with transesophageal echocardiography: Another potential embolic source
    • Isada LR, Torelli JN, Stewart WJ, Klein AL. Detection of fibrous strands on prosthetic mitral valves with transesophageal echocardiography: another potential embolic source. J Am Soc Echocardiogrpahy 1994;7:641-51.
    • (1994) J Am Soc Echocardiogrpahy , vol.7 , pp. 641-651
    • Isada, L.R.1    Torelli, J.N.2    Stewart, W.J.3    Klein, A.L.4
  • 123
    • 1542790666 scopus 로고
    • Valve strands are strongly associated with systemic embolization: A transesophageal study
    • Goodkin G, Freedberg R, Perez J, Tunick PA, Kronzon I. Valve strands are strongly associated with systemic embolization: a transesophageal study [abstract]. J Am Coll Cardiol 1994;23:129A.
    • (1994) J Am Coll Cardiol , vol.23
    • Goodkin, G.1    Freedberg, R.2    Perez, J.3    Tunick, P.A.4    Kronzon, I.5
  • 124
    • 0025355758 scopus 로고
    • Infective endocarditis, 1983-88: Echocardiographic findings and factors influencing morbidity and mortality
    • Jaffe WM, Morgan DE, Pearlman AS, Otto CM. Infective endocarditis, 1983-88: Echocardiographic findings and factors influencing morbidity and mortality. J Am Coll Cardiol 1990;15:1227-33.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 1227-1233
    • Jaffe, W.M.1    Morgan, D.E.2    Pearlman, A.S.3    Otto, C.M.4
  • 125
    • 0017163088 scopus 로고
    • Prosthetic valve endocarditis
    • Arnett EN, Roberts WC. Prosthetic valve endocarditis. Am J Cardiol 1976;38: 281-92.
    • (1976) Am J Cardiol , vol.38 , pp. 281-292
    • Arnett, E.N.1    Roberts, W.C.2
  • 126
    • 0026006548 scopus 로고
    • Echocardiographic assessment of patients with infectious endocarditis: Prediction of risk for complications
    • Sanfilippo AJ, Picard MH, Newell JB, et al. Echocardiographic assessment of patients with infectious endocarditis: prediction of risk for complications. J Am Coll Cardiol 1991;18:1191-9.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1191-1199
    • Sanfilippo, A.J.1    Picard, M.H.2    Newell, J.B.3
  • 127
    • 0024436184 scopus 로고
    • Echocardiography in infective endocarditis: Reassessment of prognostic implications of vegetati on size determined by the transthoracic and the transesophageal approach
    • MuggeA, Daniel WG, Frank G, Lichtlen PR. Echocardiography in infective endocarditis: reassessment of prognostic implications of vegetati on size determined by the transthoracic and the transesophageal approach. J Am Coll Cardiol 1989;14:631-8.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 631-638
    • Mugge, A.1    Daniel, W.G.2    Frank, G.3    Lichtlen, P.R.4
  • 129
    • 0026086834 scopus 로고
    • Improvement in the diagnosis of abscesses associated with endocarditis by transesophageal echocardiography
    • Daniel WG, MuggeA, Martin RR et al. Improvement in the diagnosis of abscesses associated with endocarditis by transesophageal echocardiography. N Engl J Med 1991;324:795-800.
    • (1991) N Engl J Med , vol.324 , pp. 795-800
    • Daniel, W.G.1    Mugge, A.2    Martin, R.R.3
  • 130
    • 0028437692 scopus 로고
    • Application of transthoracic and transesophageal echocardiography in the diagnosis and management of infective endocarditis
    • Yvorchuk KJ, Chan KL. Application of transthoracic and transesophageal echocardiography in the diagnosis and management of infective endocarditis. J Am Soc Echocardiogr 1994;14:294-308.
    • (1994) J Am Soc Echocardiogr , vol.14 , pp. 294-308
    • Yvorchuk, K.J.1    Chan, K.L.2
  • 131
    • 0017080113 scopus 로고
    • Valve ring abscess in active infective endocarditis: Frequency, location, and clues to clinical diagnosis from the study of 95 necropsy patients
    • Arnett EN, Roberts WC. Valve ring abscess in active infective endocarditis: frequency, location, and clues to clinical diagnosis from the study of 95 necropsy patients. Circulation 1976;54:140-5.
    • (1976) Circulation , vol.54 , pp. 140-145
    • Arnett, E.N.1    Roberts, W.C.2
  • 132
    • 0015373606 scopus 로고
    • Left-sided valvular active endocarditis: A study of forty-five necropsy patients
    • Buchbinder NA, Roberts WC. Left-sided valvular active endocarditis: a study of forty-five necropsy patients. Am J Med 1972;53:20-35.
    • (1972) Am J Med , vol.53 , pp. 20-35
    • Buchbinder, N.A.1    Roberts, W.C.2
  • 133
    • 0021987688 scopus 로고
    • Detection of endocarditis-associated perivalvular abscesses by two-dimensional echocardiography
    • Ellis SG, Goldstein J, Popp RL. Detection of endocarditis-associated perivalvular abscesses by two-dimensional echocardiography. J Am Coll Cardiol 1985;5: 647-53.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 647-653
    • Ellis, S.G.1    Goldstein, J.2    Popp, R.L.3
  • 134
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-4.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 135
    • 0032192099 scopus 로고    scopus 로고
    • Inacurate and misleading valve sizing: A proposed standard for valve size nomenclature
    • Christakis GT, Buth KJ, Goldman BS, et al. Inacurate and misleading valve sizing: a proposed standard for valve size nomenclature. Ann Thorac Surg 1998;66: 1193-203.
    • (1998) Ann Thorac Surg , vol.66 , pp. 1193-1203
    • Christakis, G.T.1    Buth, K.J.2    Goldman, B.S.3
  • 136
    • 0030904464 scopus 로고    scopus 로고
    • Long-term changes in left ventricular mass, chamber size and function after valve replacement in patients with severe aortic stenosis and depressed ejection fraction
    • Pela G, La Canna G, Metra M, et al. Long-term changes in left ventricular mass, chamber size and function after valve replacement in patients with severe aortic stenosis and depressed ejection fraction. Cardiology 1997;88:315-22.
    • (1997) Cardiology , vol.88 , pp. 315-322
    • Pela, G.1    La Canna, G.2    Metra, M.3
  • 137
    • 0030272139 scopus 로고    scopus 로고
    • Left ventricular mass regression early after aortic valve replacement
    • Christakis GT, Joyner CD, Morgan CD, et al. Left ventricular mass regression early after aortic valve replacement. Ann Thorac Surg 1996;62:1084-9.
    • (1996) Ann Thorac Surg , vol.62 , pp. 1084-1089
    • Christakis, G.T.1    Joyner, C.D.2    Morgan, C.D.3
  • 138
    • 12944334761 scopus 로고
    • Conventional and color Doppler assessment of prosthetic cardiac valves
    • Nanda, NC, editor. Philadelphia: Lea& Febinger
    • Von Dohlen TW, Gross CM, Rogers WB. Conventional and color Doppler assessment of prosthetic cardiac valves. In: Nanda, NC, editor. Doppler echocardiography. Philadelphia: Lea& Febinger; 1993. p. 160-74.
    • (1993) Doppler Echocardiography , pp. 160-174
    • Von Dohlen, T.W.1    Gross, C.M.2    Rogers, W.B.3
  • 140
    • 0026500769 scopus 로고
    • Value of acceleration flow signals proximal to the leaking orifice in assessing the severity of prosthetic mitral valve regurgitation
    • Yoshida K, Yoshikawa J, Akasaka T, Nishigami K, Minagoe S Value of acceleration flow signals proximal to the leaking orifice in assessing the severity of prosthetic mitral valve regurgitation. J Am Coll Cardiol 1992;19:333-8.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 333-338
    • Yoshida, K.1    Yoshikawa, J.2    Akasaka, T.3    Nishigami, K.4    Minagoe, S.5
  • 141
    • 0026952786 scopus 로고
    • A comparison of flow convergence with other transthoracic echocardiographic indexes of prosthetic mitral regurgitation
    • Cohen GI, Damson MB, Klein AL, Salcedo EE, Stewart WJ. A comparison of flow convergence with other transthoracic echocardiographic indexes of prosthetic mitral regurgitation. J Am Soc Echocardiogr 1992;5:620-7.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 620-627
    • Cohen, G.I.1    Damson, M.B.2    Klein, A.L.3    Salcedo, E.E.4    Stewart, W.J.5
  • 142
    • 0023196518 scopus 로고
    • Pitfalls in the diagnosis of periprosthetic valvular regurgitation by pulsed Doppler echocardiography
    • Come PC. Pitfalls in the diagnosis of periprosthetic valvular regurgitation by pulsed Doppler echocardiography. J Am Coll Cardiol 1987;9:1176-9.
    • (1987) J Am Coll Cardiol , vol.9 , pp. 1176-1179
    • Come, P.C.1
  • 143
    • 0024535054 scopus 로고
    • Mitral prosthesis malfunction: Comparative Doppler echocardiographic studies of mitral prostheses before and after replacement
    • Nellessen U, MaysuyamaT, Appleton CP. Tye T, Popp RL. Mitral prosthesis malfunction: comparative Doppler echocardiographic studies of mitral prostheses before and after replacement. Circulation 1989;79:330-6.
    • (1989) Circulation , vol.79 , pp. 330-336
    • Nellessen, U.1    Maysuyama, T.2    Appleton, C.P.3    Tye, T.4    Popp, R.L.5
  • 144
    • 0023794432 scopus 로고
    • Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses
    • Nellessen U, Schnittger I, Appleton CR et al. Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses. Circulation 1988;78:848-55.
    • (1988) Circulation , vol.78 , pp. 848-855
    • Nellessen, U.1    Schnittger, I.2    Appleton, C.R.3
  • 145
    • 0026575678 scopus 로고
    • Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping
    • Chao K, Moises VA, Shandas R, Elkadi T, Sahn DJ, Wantraub R. Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping. Circulation 1992;85:333-41.
    • (1992) Circulation , vol.85 , pp. 333-341
    • Chao, K.1    Moises, V.A.2    Shandas, R.3    Elkadi, T.4    Sahn, D.J.5    Wantraub, R.6
  • 146
    • 85058248789 scopus 로고
    • How reliable is flow reversal as an indicator of severe mitral regurgitation? Hydrodynamics of pulmonary venous flow reversal
    • Grimes RY, Walker PG, Leyine RA, Yoganathan AP How reliable is flow reversal as an indicator of severe mitral regurgitation? Hydrodynamics of pulmonary venous flow reversal [abstract]. J Am Soc Echocardgiogr 1994;7:S9.
    • (1994) J Am Soc Echocardgiogr , vol.7
    • Grimes, R.Y.1    Walker, P.G.2    Leyine, R.A.3    Yoganathan, A.P.4
  • 147
    • 0024436151 scopus 로고
    • Rest and exercise evaluation of St Jude Medical and Medtronic-Hall prostheses
    • Tatineni S, Barner HB, Pearson AC. Rest and exercise evaluation of St Jude Medical and Medtronic-Hall prostheses. Circulation 1989;80(suppl 1):1-16-1-23.
    • (1989) Circulation , vol.80 , Issue.1 SUPPL. , pp. 116-123
    • Tatineni, S.1    Barner, H.B.2    Pearson, A.C.3
  • 148
    • 0027389147 scopus 로고
    • Exercise hemodynamics in small (<21 mm) aortic valve prostheses assessed by Doppler echocardiography
    • Wseth R, Levang OW, Tangen G. Exercise hemodynamics in small (<21 mm) aortic valve prostheses assessed by Doppler echocardiography. Am Heart J 1993; 125:138-46.
    • (1993) Am Heart J , vol.125 , pp. 138-146
    • Wseth, R.1    Levang, O.W.2    Tangen, G.3
  • 149
    • 0024438679 scopus 로고
    • Exercise Doppler echocardiography in patients with mitral prosthetic valves
    • Reisner SA, Lichtenberg GS, Shapiro JR, et al. Exercise Doppler echocardiography in patients with mitral prosthetic valves. Am Heart J 1989;118:755-59.
    • (1989) Am Heart J , vol.118 , pp. 755-759
    • Reisner, S.A.1    Lichtenberg, G.S.2    Shapiro, J.R.3
  • 150
    • 84985800537 scopus 로고
    • Non-invasive exercise-evaluation of St. Jude and Medtronic-Hall prosthetic heart valves
    • Halbe DW, Woodruff RC, Ojile MC, et al. Non-invasive exercise-evaluation of St. Jude and Medtronic-Hall prosthetic heart valves. Circulation 1988;78(suppl 11):I-16-I-23.
    • (1988) Circulation , vol.78 , Issue.11 SUPPL.
    • Halbe, D.W.1    Woodruff, R.C.2    Ojile, M.C.3
  • 151
    • 0030865909 scopus 로고    scopus 로고
    • Usefulness of dobutamine echocardiography in the hemodynamic assessment of mechanical prostheses in the aortic valve position
    • Zabalgoitia M, Kopec K, Abochamh DA, Oneschuk L, Herrera CJ, O'Rourke RA. Usefulness of dobutamine echocardiography in the hemodynamic assessment of mechanical prostheses in the aortic valve position. Am J Cardiol 1997; 80:523-6.
    • (1997) Am J Cardiol , vol.80 , pp. 523-526
    • Zabalgoitia, M.1    Kopec, K.2    Abochamh, D.A.3    Oneschuk, L.4    Herrera, C.J.5    O'Rourke, R.A.6
  • 152
    • 85058249046 scopus 로고
    • Stress Doppler assessment of aortic valve prostheses: Treadmill exercise vs dobutamine
    • Dressler FA, St Vrain JA, Kaiser G, et al. Stress Doppler assessment of aortic valve prostheses: treadmill exercise vs dobutamine [abstract]. J Am Soc Echocardiogr 1994;7:S54.
    • (1994) J Am Soc Echocardiogr , vol.7
    • Dressler, F.A.1    St Vrain, J.A.2    Kaiser, G.3
  • 153
    • 0028857528 scopus 로고
    • Usefulness of dobutamine echocardiography in distinguishing severe from nonsevere valvular aortic stenosis in patients with depressed left ventricular function and low transvalvular gradients
    • deFilippi CR, Willett DL, Brickner E, et al. Usefulness of dobutamine echocardiography in distinguishing severe from nonsevere valvular aortic stenosis in patients with depressed left ventricular function and low transvalvular gradients. Am J Cardiol 1995;75:191-4.
    • (1995) Am J Cardiol , vol.75 , pp. 191-194
    • DeFilippi, C.R.1    Willett, D.L.2    Brickner, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.