메뉴 건너뛰기




Volumn 46, Issue 5, 2012, Pages 313-317

Comparison of modified Kessler and Yotsumoto-Dona suture: A biomechanical study on porcine tendons

Author keywords

Flexor; Kessler; Suture; Tendon; Tensile strength; Two strand

Indexed keywords

ANIMAL; ANIMAL MODEL; ARTICLE; BIOMECHANICS; COMPARATIVE STUDY; SUTURING METHOD; SWINE; TENDON; TENSILE STRENGTH;

EID: 84866683135     PISSN: 2000656X     EISSN: None     Source Type: Journal    
DOI: 10.3109/2000656X.2012.700005     Document Type: Article
Times cited : (9)

References (25)
  • 1
    • 33847309905 scopus 로고    scopus 로고
    • Indications, methods, postoperative motion and outcome evaluation of primary flexor tendon repairs in Zone 2
    • Tang JB. Indications, methods, postoperative motion and outcome evaluation of primary flexor tendon repairs in Zone 2. J Hand Surg Eur Vol 2007;32:118-29.
    • (2007) J Hand Surg Eur Vol , vol.32 , pp. 118-129
    • Tang, J.B.1
  • 2
    • 0014630009 scopus 로고
    • Primary repair without immobilization of flexor tendon division within the digital sheath An experimental and clinical study
    • Kessler I, Nissim F. Primary repair without immobilization of flexor tendon division within the digital sheath. An experimental and clinical study. Acta Orthop Scand 1969;40:587-601.
    • (1969) Acta Orthop Scand , vol.40 , pp. 587-601
    • Kessler, I.1    Nissim, F.2
  • 3
    • 0018424934 scopus 로고
    • The locking loop tendon suture
    • Pennington DG. The locking loop tendon suture. Plast Reconstr Surg 1979;63:648-52.
    • (1979) Plast Reconstr Surg , vol.63 , pp. 648-652
    • Pennington, D.G.1
  • 4
    • 0021141474 scopus 로고
    • History, current status, and aspects of hand surgery in Japan
    • Tajima T. History, current status, and aspects of hand surgery in Japan. Clin Orthop Relat Res 1984;184:41-9.
    • (1984) Clin Orthop Relat Res , vol.184 , pp. 41-49
    • Tajima, T.1
  • 5
    • 0024439851 scopus 로고
    • Flexor tendon surgery. Part 1: Primary flexor tendon repair
    • Strickland JW. Flexor tendon surgery. Part 1: Primary flexor tendon repair. J Hand Surg 1989;14B:261-72.
    • (1989) J Hand Surg , vol.14 B , pp. 261-272
    • Strickland, J.W.1
  • 6
    • 20544478238 scopus 로고    scopus 로고
    • IFSSH Flexor Tendon Committee report
    • Amadio P, An KN, Ejeskar A, et al. IFSSH Flexor Tendon Committee report. J Hand Surg 2005;30B:100-16.
    • (2005) J Hand Surg , vol.30 B , pp. 100-116
    • Amadio, P.1    An, K.N.2    Ejeskar, A.3
  • 7
    • 17644384468 scopus 로고    scopus 로고
    • The evolution of early mobilization of the repaired flexor tendon
    • Pettengill KM. The evolution of early mobilization of the repaired flexor tendon. J Hand Ther 2005;18:157-68.
    • (2005) J Hand Ther , vol.18 , pp. 157-168
    • Pettengill, K.M.1
  • 8
    • 0034045166 scopus 로고    scopus 로고
    • Effect of suture size on locking and grasping flexor tendon repair techniques
    • Hatanaka H, Manske PR. Effect of suture size on locking and grasping flexor tendon repair techniques. Clin Orthop Relat Res 2000;375:267-74.
    • (2000) Clin Orthop Relat Res , vol.375 , pp. 267-274
    • Hatanaka, H.1    Manske, P.R.2
  • 9
    • 0742305398 scopus 로고    scopus 로고
    • Gliding characteristics and gap formation for locking and grasping tendon repairs: A biomechanical study in a human cadaver model
    • Tanaka T, Amadio PC, Zhao C, Zobitz ME, Yang C, An KA. Gliding characteristics and gap formation for locking and grasping tendon repairs: a biomechanical study in a human cadaver model. J Hand Surg 2004;29A:6-14.
    • (2004) J Hand Surg , vol.29 A , pp. 6-14
    • Tanaka, T.1    Amadio, P.C.2    Zhao, C.3    Zobitz, M.E.4    Yang, C.5    An, K.A.6
  • 10
    • 26244461765 scopus 로고    scopus 로고
    • Optimum locations of the locking loop and knot in tendon sutures based on the locking Kessler method
    • Yotsumoto T, Mori R, Uchio Y. Optimum locations of the locking loop and knot in tendon sutures based on the locking Kessler method. J Orthop Sci 2005;10:515-20.
    • (2005) J Orthop Sci , vol.10 , pp. 515-520
    • Yotsumoto, T.1    Mori, R.2    Uchio, Y.3
  • 11
    • 33845203717 scopus 로고    scopus 로고
    • Biomechanical differences resulting from the combination of suture materials and repair techniques
    • Yamagami N, Mori R, Yotsumoto T, Hatanaka H, Takao M, Uchio Y. Biomechanical differences resulting from the combination of suture materials and repair techniques. J Orthop Sci 2006;11:614-19.
    • (2006) J Orthop Sci , vol.11 , pp. 614-619
    • Yamagami, N.1    Mori, R.2    Yotsumoto, T.3    Hatanaka, H.4    Takao, M.5    Uchio, Y.6
  • 13
    • 0141732297 scopus 로고    scopus 로고
    • Biomechanical properties of four circumferential flexor tendon suture techniques
    • Dona E, Turner AW, Gianoutsos MP, Walsh WR. Biomechanical properties of four circumferential flexor tendon suture techniques. J Hand Surg 2003;28A:824-31.
    • (2003) J Hand Surg , vol.28 A , pp. 824-831
    • Dona, E.1    Turner, A.W.2    Gianoutsos, M.P.3    Walsh, W.R.4
  • 14
    • 0036908369 scopus 로고    scopus 로고
    • Primary flexor tendon repair-operative repair, pulley management and rehabilitation
    • Elliot D. Primary flexor tendon repair-operative repair, pulley management and rehabilitation. J Hand Surg 2002; 27B:507-13.
    • (2002) J Hand Surg , vol.27 B , pp. 507-513
    • Elliot, D.1
  • 15
    • 0032459942 scopus 로고    scopus 로고
    • Flexor digitorum profundus tendon-to-bone repair: An ex vivo biomechanical analysis of 3 pullout suture techniques
    • Silva MJ, Hollstien SB, Brodt MD, et al. Flexor digitorum profundus tendon-to-bone repair: an ex vivo biomechanical analysis of 3 pullout suture techniques. J Hand Surg 1998; 23A:120-6.
    • (1998) J Hand Surg , vol.23 A , pp. 120-126
    • Silva, M.J.1    Hollstien, S.B.2    Brodt, M.D.3
  • 16
  • 17
    • 8144219527 scopus 로고    scopus 로고
    • Effect of gap size on gliding resistance after flexor tendon repair
    • Zhao C, Amadio PC, Tanaka T, et al. Effect of gap size on gliding resistance after flexor tendon repair. J Bone Joint Surg 2004;86A:2482-8.
    • (2004) J Bone Joint Surg , vol.86 A , pp. 2482-2488
    • Zhao, C.1    Amadio, P.C.2    Tanaka, T.3
  • 19
    • 58149102814 scopus 로고    scopus 로고
    • Biomechanical comparison of modified Kessler and running suture repair in 3 different animal tendons and in human flexor tendons
    • Hausmann JT, Vekszler G, Bijak M, Benesch T, Vécsei V, Gäbler C. Biomechanical comparison of modified Kessler and running suture repair in 3 different animal tendons and in human flexor tendons. J Hand Surg 2009;34A:93-101.
    • (2009) J Hand Surg , vol.34 A , pp. 93-101
    • Hausmann, J.T.1    Vekszler, G.2    Bijak, M.3    Benesch, T.4    Vécsei, V.5    Gäbler, C.6
  • 21
    • 40649120916 scopus 로고    scopus 로고
    • The effects of freezing on the tensile properties of repaired porcine flexor tendon
    • Hirpara KM, Sullivan PJ, O'Sullivan ME. The effects of freezing on the tensile properties of repaired porcine flexor tendon. J Hand Surg 2008;33A:353-8.
    • (2008) J Hand Surg , vol.33 A , pp. 353-358
    • Hirpara, K.M.1    Sullivan, P.J.2    O'Sullivan, M.E.3
  • 22
    • 0029837416 scopus 로고    scopus 로고
    • Mechanical properties of various circumferential tendon suture techniques
    • Kubota H, Aoki M, Pruitt DL, Manske PR. Mechanical properties of various circumferential tendon suture techniques. J Hand Surg 1996;21B:474-80.
    • (1996) J Hand Surg , vol.21 B , pp. 474-480
    • Kubota, H.1    Aoki, M.2    Pruitt, D.L.3    Manske, P.R.4
  • 23
    • 0025009182 scopus 로고
    • Double loop locking suture: A technique of tendon repair for early active mobilization. Part I: Evolution of technique and experimental study
    • Lee H. Double loop locking suture: a technique of tendon repair for early active mobilization. Part I: Evolution of technique and experimental study. J Hand Surg 1990;15A:945-52.
    • (1990) J Hand Surg , vol.15 A , pp. 945-952
    • Lee, H.1
  • 24
    • 35548933400 scopus 로고    scopus 로고
    • Flexor tendon repair using the two-strand side-locking loop technique to tolerate aggressive active mobilization immediately after surgery
    • Kuwata S, Mori R, Yotsumoto T, Uchio Y. Flexor tendon repair using the two-strand side-locking loop technique to tolerate aggressive active mobilization immediately after surgery. Clin Biomech 2007;22:1083-7.
    • (2007) Clin Biomech , vol.22 , pp. 1083-1087
    • Kuwata, S.1    Mori, R.2    Yotsumoto, T.3    Uchio, Y.4
  • 25
    • 33845899996 scopus 로고    scopus 로고
    • Optimum location of knot for tendon surgery in side-locking loop technique
    • Komatsu F, Mori R, Uchio Y, Hatanaka H. Optimum location of knot for tendon surgery in side-locking loop technique. Clin Biomech 2007;22:112-19.
    • (2007) Clin Biomech , vol.22 , pp. 112-119
    • Komatsu, F.1    Mori, R.2    Uchio, Y.3    Hatanaka, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.