메뉴 건너뛰기




Volumn 27, Issue 10, 2012, Pages 2208-2216

A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems

Author keywords

BODY COMPOSITION; CROSS CALIBRATION; OBESITY; OSTEOPOROSIS; PERCENT BODY FAT

Indexed keywords

ADOLESCENT; ADULT; AGE DISTRIBUTION; AGED; ARTICLE; BODY COMPOSITION; BODY HEIGHT; BODY WEIGHT; BONE DENSITY; BONE TISSUE; CALIBRATION; CHILD; CHINA; CONTROLLED STUDY; CONVENIENCE SAMPLE; DIAGNOSTIC TEST ACCURACY STUDY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; HUMAN; MALE; NORMAL HUMAN; PEDIATRICS; PRESCHOOL CHILD; SCHOOL CHILD; SOFT TISSUE; STANDARDIZATION; UNITED STATES; WHOLE BODY BONE DENSITY; WHOLE BODY SCINTISCANNING;

EID: 84866658570     PISSN: 08840431     EISSN: 15234681     Source Type: Journal    
DOI: 10.1002/jbmr.1654     Document Type: Article
Times cited : (154)

References (17)
  • 1
    • 0029318474 scopus 로고
    • Universal standardization for dual X-ray absorptiometry: Patient and phantom cross-calibration results
    • Genant HK,. Universal standardization for dual X-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Res. 1995; 10 (6): 997-8.
    • (1995) J Bone Miner Res , vol.10 , Issue.6 , pp. 997-998
    • Genant, H.K.1
  • 2
    • 15344350309 scopus 로고    scopus 로고
    • Dual-energy x-ray absorptiometry measurements of total-body bone mineral during weight change
    • Tothill P,. Dual-energy x-ray absorptiometry measurements of total-body bone mineral during weight change. J Clin Densitom. 2006; 8 (1): 31-8.
    • (2006) J Clin Densitom , vol.8 , Issue.1 , pp. 31-38
    • Tothill, P.1
  • 4
    • 0028568086 scopus 로고
    • Precision and accuracy of measurements of whole-body bone mineral: Comparisons between Hologic, Lunar, and Norland dual-energy X-ray absorptiometers
    • Tothill P, Avenell A, Reid DM,. Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar, and Norland dual-energy X-ray absorptiometers. Br J Radiol. 1994; 67: 1210-7.
    • (1994) Br J Radiol , vol.67 , pp. 1210-1217
    • Tothill, P.1    Avenell, A.2    Reid, D.M.3
  • 5
    • 0029000960 scopus 로고
    • Comparisons between three dual-energy X-ray absorptiometers used for measuring spine and femur
    • Tothill P, Fenner JA, Reid DM,. Comparisons between three dual-energy X-ray absorptiometers used for measuring spine and femur. Br J Radiol. 1995; 68 (810): 621-9.
    • (1995) Br J Radiol , vol.68 , Issue.810 , pp. 621-629
    • Tothill, P.1    Fenner, J.A.2    Reid, D.M.3
  • 6
    • 0029806795 scopus 로고    scopus 로고
    • Comparisons between fat measurements by dual-energy X-ray absorptiometry, underwater weighing and magnetic resonance imaging in healthy women
    • Tothill P, Han TS, Avenell A, McNeill G, Reid DM,. Comparisons between fat measurements by dual-energy X-ray absorptiometry, underwater weighing and magnetic resonance imaging in healthy women. Eur J Clin Nutr. 1996; 50 (11): 747-52. (Pubitemid 26393466)
    • (1996) European Journal of Clinical Nutrition , vol.50 , Issue.11 , pp. 747-752
    • Tothill, P.1    Han, T.S.2    Avenell, A.3    McNeill, G.4    Reid, D.M.5
  • 7
    • 0034086159 scopus 로고    scopus 로고
    • Comparisons between Hologic QDR 1000W, QDR 4500A, and Lunar Expert dual-energy X-ray absorptiometry scanners used for measuring total body bone and soft tissue
    • Tothill P, Hannan WJ,. Comparisons between Hologic QDR 1000W, QDR 4500A, and Lunar Expert dual-energy X-ray absorptiometry scanners used for measuring total body bone and soft tissue. Ann NY Acad Sci. 2000; 904: 63-71. (Pubitemid 30389159)
    • (2000) Annals of the New York Academy of Sciences , vol.904 , pp. 63-71
    • Tothill, P.1    Hannan, W.J.2
  • 8
    • 0030704308 scopus 로고    scopus 로고
    • Anomalies in the measurement of changes in total-body bone mineral by dual-energy X-ray absorptiometry during weight change
    • Tothill P, Hannan WJ, Cowen S, Freeman CP,. Anomalies in the measurement of changes in total-body bone mineral by dual-energy X-ray absorptiometry during weight change. J Bone Miner Res. 1997; 12 (11): 1908-21. (Pubitemid 27500203)
    • (1997) Journal of Bone and Mineral Research , vol.12 , Issue.11 , pp. 1908-1921
    • Tothill, P.1    Hannan, W.J.2    Cowen, S.3    Freeman, C.P.4
  • 9
    • 0032764603 scopus 로고    scopus 로고
    • Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments
    • JUL
    • Tothill P, Laskey MA, Orphanidou CI, van Wijk M,. Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments. Br J Radiol. 1999; 72 (859): 661-9. (Pubitemid 29355611)
    • (1999) British Journal of Radiology , vol.72 , pp. 661-669
    • Tothill, P.1    Laskey, M.A.2    Orphanidou, C.I.3    Van Wijk, M.4
  • 10
    • 0030869643 scopus 로고    scopus 로고
    • Universal standardization of bone density measurements: A method with optimal properties for calibration among several instruments
    • DOI 10.1359/jbmr.1997.12.9.1463
    • Hui SL, Gao S, Zhou XH, Johnston CC Jr, Lu Y, Gluer CC, Grampp S, Genant H,. Universal standardization of bone density measurements: a method with optimal properties for calibration among several instruments. J Bone Miner Res. 1997; 12 (9): 1463-70. (Pubitemid 27375390)
    • (1997) Journal of Bone and Mineral Research , vol.12 , Issue.9 , pp. 1463-1470
    • Hui, S.L.1    Gao, S.2    Zhou, X.-H.3    Johnston Jr., C.C.4    Lu, Y.5    Gluer, C.C.6    Grampp, S.7    Genant, H.8
  • 11
    • 0034963997 scopus 로고    scopus 로고
    • Standardization of bone mineral density at femoral neck, trochanter and ward's triangle
    • DOI 10.1007/s001980170087
    • Lu Y, Fuerst T, Hui S, Genant HK,. Standardization of bone mineral density at femoral neck, trochanter and Ward's triangle. Osteoporos Int. 2001; 12 (6): 438-44. (Pubitemid 32607085)
    • (2001) Osteoporosis International , vol.12 , Issue.6 , pp. 438-444
    • Lu, Y.1    Fuerst, T.2    Hui, S.3    Genant, H.K.4
  • 12
    • 0031536511 scopus 로고    scopus 로고
    • Improvements on cross-validation: The.632+ bootstrap method
    • Efron B, Tibshirani R,. Improvements on cross-validation: The.632+ bootstrap method. J Amer Stat Assoc. 1997; 92 (438): 548-60.
    • (1997) J Amer Stat Assoc , vol.92 , Issue.438 , pp. 548-560
    • Efron, B.1    Tibshirani, R.2
  • 13
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG,. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8 (2): 135-60. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 70349280466 scopus 로고    scopus 로고
    • Dual energy X-ray absorptiometry body composition reference values from NHANES
    • Kelly TL, Wilson KE, Heymsfield SB,. Dual energy X-ray absorptiometry body composition reference values from NHANES. PLoS ONE. 2009; 4 (9): e7038.
    • (2009) PLoS ONE , vol.4 , Issue.9
    • Kelly, T.L.1    Wilson, K.E.2    Heymsfield, S.B.3
  • 17
    • 3342969287 scopus 로고    scopus 로고
    • Dual X-ray absorptiometry: Cross-calibration of a new fan-beam system
    • Blake GM, Harrison EJ, Adams JE,. Dual X-ray absorptiometry: cross-calibration of a new fan-beam system. Calcif Tissue Int. 2004; 75 (1): 7-14. (Pubitemid 38989214)
    • (2004) Calcified Tissue International , vol.75 , Issue.1 , pp. 7-14
    • Blake, G.M.1    Harrison, E.J.2    Adams, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.