메뉴 건너뛰기




Volumn 35, Issue 4, 2012, Pages 975-977

Balloon-assisted retrieval of tilted optease IVC filter

Author keywords

[No Author keywords available]

Indexed keywords

LOW MOLECULAR WEIGHT HEPARIN;

EID: 84866622210     PISSN: 01741551     EISSN: 1432086X     Source Type: Journal    
DOI: 10.1007/s00270-011-0332-6     Document Type: Letter
Times cited : (7)

References (13)
  • 1
    • 44949085655 scopus 로고    scopus 로고
    • Vena cava filters for the prevention of pulmonary embolism (review)
    • Young T, Tang H, Hughes R (2007) Vena cava filters for the prevention of pulmonary embolism (review). Cochrane Database Syst Rev (4):CD006212
    • (2007) Cochrane Database Syst Rev , Issue.4
    • Young, T.1    Tang, H.2    Hughes, R.3
  • 2
    • 22544478179 scopus 로고    scopus 로고
    • Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: The PREPIC (prevention du risque d'embolie pulmonaire par interruption cave) randomized study
    • The PREPIC Study Group
    • The PREPIC Study Group (2005) Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: the PREPIC (prevention du risque d'embolie pulmonaire par interruption cave) randomized study. Circulation 112:416-422
    • (2005) Circulation , vol.112 , pp. 416-422
  • 3
    • 79959615157 scopus 로고    scopus 로고
    • OptEase vena cava filter optimal indwelling time and retrievability
    • Rimon U, Bensaid P, Golan G et al (2011) OptEase vena cava filter optimal indwelling time and retrievability. Cardiovasc Interv Radiol 34:532-535
    • (2011) Cardiovasc Interv Radiol , vol.34 , pp. 532-535
    • Rimon, U.1    Bensaid, P.2    Golan, G.3
  • 4
    • 33846226087 scopus 로고    scopus 로고
    • Practice patterns and outcomes of retrievable vena cava filters in trauma patients: An AAST multicentre study
    • Karmy-Jones R, Jurkovich GJ, Velhamos GC et al (2007) Practice patterns and outcomes of retrievable vena cava filters in trauma patients: an AAST multicentre study. J Trauma 62:17-25
    • (2007) J Trauma , vol.62 , pp. 17-25
    • Karmy-Jones, R.1    Jurkovich, G.J.2    Velhamos, G.C.3
  • 5
    • 33750083034 scopus 로고    scopus 로고
    • Outcomes with retrievable inferior vena cava filters: A multicenter study
    • Ray CE, Mitchell E, Zipser S et al (2006) Outcomes with retrievable inferior vena cava filters: a multicenter study. J Vasc Interv Radiol 17:1595-1602
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 1595-1602
    • Ray, C.E.1    Mitchell, E.2    Zipser, S.3
  • 6
    • 70450225362 scopus 로고    scopus 로고
    • High-risk retrieval of adherent and chronically implanted IVC filters: Techniques for removal and management of thrombotic complications
    • Kuo WT, Tong RT, Hwang GL et al (2009) High-risk retrieval of adherent and chronically implanted IVC filters: techniques for removal and management of thrombotic complications. J Vasc Interv Radiol 20:1548-1556
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 1548-1556
    • Kuo, W.T.1    Tong, R.T.2    Hwang, G.L.3
  • 8
    • 79955552045 scopus 로고    scopus 로고
    • Longterm-safety and Effectiveness of the "optEase" vena cava filter
    • Kalva SP, Marentis TC, Yeddula K et al (2011) Longterm-safety and effectiveness of the "OptEase" vena cava filter. Cardiovasc Interv Radiol 34:331-337
    • (2011) Cardiovasc Interv Radiol , vol.34 , pp. 331-337
    • Kalva, S.P.1    Marentis, T.C.2    Yeddula, K.3
  • 9
    • 64849096813 scopus 로고    scopus 로고
    • A "buddy wire" technique for successful OptEase filter retrieval
    • Pfammatter T, Heckelhammer L, Pfiffner R (2009) A "buddy wire" technique for successful OptEase filter retrieval. J Vasc Interv Radiol 20:656-659
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 656-659
    • Pfammatter, T.1    Heckelhammer, L.2    Pfiffner, R.3
  • 10
    • 57849159275 scopus 로고    scopus 로고
    • Techniques used for difficult retrievals of the Gunther tulip inferior vena cava filter: Experience in 32 patients
    • Van Ha TG, Vinokur O, Lorenz J et al (2009) Techniques used for difficult retrievals of the Gunther tulip inferior vena cava filter: experience in 32 patients. J Vasc Interv Radiol 20:92-99
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 92-99
    • Van Ha, T.G.1    Vinokur, O.2    Lorenz, J.3
  • 11
    • 69349084865 scopus 로고    scopus 로고
    • Balloon-assisted removal of tilted inferior vena cava filters with embedded tips
    • Lynch FC (2009) Balloon-assisted removal of tilted inferior vena cava filters with embedded tips. J Vasc Interv Radiol 20:1210-1214
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 1210-1214
    • Lynch, F.C.1
  • 12
    • 84864304655 scopus 로고    scopus 로고
    • Complex retrieval of embedded IVC filters: Alternative techniques and histologic tissue analysis
    • doi:10.1007/s00270-011-0175-1
    • Kuo WT, Cupp JS, Louie JD et al (2011) Complex retrieval of embedded IVC filters: alternative techniques and histologic tissue analysis. Cardiovasc Interv Radiol. doi:10.1007/s00270-011-0175-1
    • (2011) Cardiovasc Interv Radiol
    • Kuo, W.T.1    Cupp, J.S.2    Louie, J.D.3
  • 13
    • 49749098880 scopus 로고    scopus 로고
    • Embedded inferior vena cava filter removal: Use of endobronchial forceps
    • Stavropoulos SW, Dixon RG, Burke CT et al (2008) Embedded inferior vena cava filter removal: use of endobronchial forceps. J Vasc Interv Radiol 19:1297-1301
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1297-1301
    • Stavropoulos, S.W.1    Dixon, R.G.2    Burke, C.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.