Volumn 50, Issue 1, 2013, Pages 732-742

Uncertainties in energy and economic performance of HVAC systems and energy recovery ventilators due to uncertainties in building and HVAC parameters

Author keywords

Building HVAC system; Energy recovery ventilator; Energy savings; Payback period; Sensitivity analysis; Uncertainty

Indexed keywords

BUILDING DESIGN; BUILDING PARAMETERS; CAPITAL COSTS; CHICAGO; COOLING ENERGY; ECONOMIC PERFORMANCE; ENERGY RATES; ENERGY RECOVERY; ENERGY RECOVERY DEVICES; ENERGY SAVINGS POTENTIAL; ENERGY USE; EXHAUST AIR; HEATING ENERGY; HEATING LOAD; HVAC EQUIPMENT; HVAC SYSTEM; IN-BUILDINGS; INITIAL COSTS; INPUT PARAMETER; PAYBACK PERIODS; PEAK COOLING LOAD; SIGNIFICANT IMPACTS; UNCERTAINTY; VENTILATION RATE;

EID: 84866549187     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2012.08.021     Document Type: Conference Paper
Times cited : (65)

References (34)
  • 2
    • 41649119410 scopus 로고    scopus 로고
    • Simultaneous heat and moisture transfer through a composite supported liquid membrane
    • L.Z. Zhang, and F. Xiao Simultaneous heat and moisture transfer through a composite supported liquid membrane International Journal of Heat and Mass Transfer 51 9-10 2008 2179 2189
    • (2008) International Journal of Heat and Mass Transfer , vol.51 , Issue.910 , pp. 2179-2189
    • Zhang, L.Z.1    Xiao, F.2
  • 3
    • 85092429076 scopus 로고    scopus 로고
    • Air-to-air energy recovery
    • R.W. Besant, and C.J. Simonson Air-to-air energy recovery ASHRAE Journal 45 4 2003 42 52
    • (2003) ASHRAE Journal , vol.45 , Issue.4 , pp. 42-52
    • Besant, R.W.1    Simonson, C.J.2
  • 4
    • 10044243813 scopus 로고    scopus 로고
    • Practical thermal performance correlations for molecular sieve and silica gel loaded enthalpy wheels
    • J.W. Jeong, and S.A. Mumma Practical thermal performance correlations for molecular sieve and silica gel loaded enthalpy wheels Applied Thermal Engineering 25 5-6 2005 719 740
    • (2005) Applied Thermal Engineering , vol.25 , Issue.56 , pp. 719-740
    • Jeong, J.W.1    Mumma, S.A.2
  • 5
    • 77649273812 scopus 로고    scopus 로고
    • Performance analysis of a membrane-based energy recovery ventilator: Effects of membrane spacing and thickness on the ventilator performance
    • J.C. Min, and M. Su Performance analysis of a membrane-based energy recovery ventilator: effects of membrane spacing and thickness on the ventilator performance Applied Thermal Engineering 30 8-9 2010 991 997
    • (2010) Applied Thermal Engineering , vol.30 , Issue.89 , pp. 991-997
    • Min, J.C.1    Su, M.2
  • 6
    • 80052930513 scopus 로고    scopus 로고
    • Performance analysis of a membrane-based energy recovery ventilator: Effects of outdoor air state
    • J.C. Min, and M. Su Performance analysis of a membrane-based energy recovery ventilator: effects of outdoor air state Applied Thermal Engineering 31 17-18 2011 4036 4043
    • (2011) Applied Thermal Engineering , vol.31 , Issue.1718 , pp. 4036-4043
    • Min, J.C.1    Su, M.2
  • 7
    • 79951958897 scopus 로고    scopus 로고
    • Applicability and optimum control strategy of energy recovery ventilators in different climatic conditions
    • M. Rasouli, C.J. Simonson, and R.W. Besant Applicability and optimum control strategy of energy recovery ventilators in different climatic conditions Energy and Buildings 42 9 2010 1376 1385
    • (2010) Energy and Buildings , vol.42 , Issue.9 , pp. 1376-1385
    • Rasouli, M.1    Simonson, C.J.2    Besant, R.W.3
  • 8
    • 84355164093 scopus 로고    scopus 로고
    • Application of a run-around membrane energy exchanger in an office building HVAC system
    • M. Rasouli, S. Akbari, H. Hemingson, R.W. Besant, and C.J. Simonson Application of a run-around membrane energy exchanger in an office building HVAC system ASHRAE Transactions 117 2 2011 686 703
    • (2011) ASHRAE Transactions , vol.117 , Issue.2 , pp. 686-703
    • Rasouli, M.1    Akbari, S.2    Hemingson, H.3    Besant, R.W.4    Simonson, C.J.5
  • 9
    • 84355165838 scopus 로고    scopus 로고
    • Energetic, economic and environmental analysis of a health-care facility HVAC system equipped with a run-around membrane energy exchanger
    • submitted for publication
    • M. Rasouli, S. Akbari, C.J. Simonson, R.W. Besant, Energetic, economic and environmental analysis of a health-care facility HVAC system equipped with a run-around membrane energy exchanger, Energy and Building, submitted for publication.
    • Energy and Building
    • Rasouli, M.1    Akbari, S.2    Simonson, C.J.3    Besant, R.W.4
  • 10
    • 71849084353 scopus 로고    scopus 로고
    • Efficiency of energy recovery ventilator with various weathers and its energy saving performance in a residential apartment
    • J.J. Liu, W.S. Li, J. Liu, and B. Wang Efficiency of energy recovery ventilator with various weathers and its energy saving performance in a residential apartment Energy and Buildings 42 1 2010 43 49
    • (2010) Energy and Buildings , vol.42 , Issue.1 , pp. 43-49
    • Liu, J.J.1    Li, W.S.2    Liu, J.3    Wang, B.4
  • 11
    • 34748859739 scopus 로고    scopus 로고
    • Performance of energy recovery ventilators with various weathers and temperature set-points
    • Y.P. Zhou, J.Y. Wu, and R.Z. Wang Performance of energy recovery ventilators with various weathers and temperature set-points Energy and Buildings 39 12 2007 1202 1210
    • (2007) Energy and Buildings , vol.39 , Issue.12 , pp. 1202-1210
    • Zhou, Y.P.1    Wu, J.Y.2    Wang, R.Z.3
  • 12
    • 33645421996 scopus 로고    scopus 로고
    • Extracted ventilation air heat recovery efficiency as a function of a building's thermal properties
    • E. Juodis Extracted ventilation air heat recovery efficiency as a function of a building's thermal properties Energy and Buildings 38 6 2006 568 573
    • (2006) Energy and Buildings , vol.38 , Issue.6 , pp. 568-573
    • Juodis, E.1
  • 14
    • 0029751163 scopus 로고    scopus 로고
    • Sensitivity analysis of energy performance of office buildings
    • J.C. Lam, and S.C.M. Hui Sensitivity analysis of energy performance of office buildings Building and Environment 31 1 1996 27 39
    • (1996) Building and Environment , vol.31 , Issue.1 , pp. 27-39
    • Lam, J.C.1    Hui, S.C.M.2
  • 15
    • 52949095000 scopus 로고    scopus 로고
    • Sensitivity analysis and energy conservation measures implications
    • J.C. Lam, K.K.W. Wan, and L. Yang Sensitivity analysis and energy conservation measures implications Energy Conversion and Management 49 11 2008 3170 3177
    • (2008) Energy Conversion and Management , vol.49 , Issue.11 , pp. 3170-3177
    • Lam, J.C.1    Wan, K.K.W.2    Yang, L.3
  • 16
    • 79959374497 scopus 로고    scopus 로고
    • Identification of the building parameters that influence heating and cooling energy loads for apartment buildings in hot-humid climates
    • Y. Yildiz, and Z.D. Arsan Identification of the building parameters that influence heating and cooling energy loads for apartment buildings in hot-humid climates Energy 36 7 2011 4287 4296
    • (2011) Energy , vol.36 , Issue.7 , pp. 4287-4296
    • Yildiz, Y.1    Arsan, Z.D.2
  • 17
    • 33751571796 scopus 로고    scopus 로고
    • Energy efficient building design using sensitivity analysis - A case study
    • P. Tavares, and A. Martins Energy efficient building design using sensitivity analysis - a case study Energy and Buildings 39 1 2007 23 31
    • (2007) Energy and Buildings , vol.39 , Issue.1 , pp. 23-31
    • Tavares, P.1    Martins, A.2
  • 18
    • 77956531746 scopus 로고    scopus 로고
    • Warm season cooling requirements for passive buildings in southeastern Europe (Romania)
    • V. Badescu, N. Laaser, and R. Crutescu Warm season cooling requirements for passive buildings in southeastern Europe (Romania) Energy 35 8 2010 3284 3300
    • (2010) Energy , vol.35 , Issue.8 , pp. 3284-3300
    • Badescu, V.1    Laaser, N.2    Crutescu, R.3
  • 19
    • 54249159971 scopus 로고    scopus 로고
    • Economic optimization and sensitivity analysis of photovoltaic system in residential buildings
    • H.B. Ren, W.J. Gao, and Y.J. Ruan Economic optimization and sensitivity analysis of photovoltaic system in residential buildings Renewable Energy 34 3 2009 883 889
    • (2009) Renewable Energy , vol.34 , Issue.3 , pp. 883-889
    • Ren, H.B.1    Gao, W.J.2    Ruan, Y.J.3
  • 20
    • 78650731639 scopus 로고    scopus 로고
    • Primary energy and economic analysis of combined heating, cooling and power systems
    • M.D. Schicktanz, J. Wapler, and H.M. Henning Primary energy and economic analysis of combined heating, cooling and power systems Energy 36 1 2011 575 585
    • (2011) Energy , vol.36 , Issue.1 , pp. 575-585
    • Schicktanz, M.D.1    Wapler, J.2    Henning, H.M.3
  • 21
    • 33744967723 scopus 로고    scopus 로고
    • The financial viability of an SOFC cogeneration system in single-family dwellings
    • K. Alanne, A. Saari, V.I. Ugursal, and J. Good The financial viability of an SOFC cogeneration system in single-family dwellings Journal of Power Sources 158 1 2006 403 416
    • (2006) Journal of Power Sources , vol.158 , Issue.1 , pp. 403-416
    • Alanne, K.1    Saari, A.2    Ugursal, V.I.3    Good, J.4
  • 24
    • 79951951661 scopus 로고    scopus 로고
    • Thermal Energy System Specialist, LLC Madison, WI, USA
    • J.W. Thornton TESS Libraries 2.0 2009 Thermal Energy System Specialist, LLC Madison, WI, USA
    • (2009) TESS Libraries 2.0
    • Thornton, J.W.1
  • 26
    • 58849110464 scopus 로고    scopus 로고
    • National Climatic Data Center, NOAA
    • Comparative Climatic Data 2001 National Climatic Data Center, NOAA
    • (2001) Comparative Climatic Data
  • 28
    • 78649724473 scopus 로고    scopus 로고
    • The American Society of Mechanical Engineers New York, NY
    • ASME PTC 19.1-2005, Test Uncertainty 2005 The American Society of Mechanical Engineers New York, NY
    • (2005) ASME PTC 19.1-2005, Test Uncertainty
  • 30
    • 77954648768 scopus 로고    scopus 로고
    • U.S. Energy Information Administration
    • U.S. Energy Information Administration, Independent Statistics & Analysis. http://www.eia.gov/state.
    • Independent Statistics & Analysis
  • 33
    • 0003513478 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.
    • ASHRAE, 2008 ASHRAE Handbook - HVAC Systems and Equipment, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc., 2008.
    • (2008) ASHRAE, 2008 ASHRAE Handbook - HVAC Systems and Equipment
  • 34
    • 0035251202 scopus 로고    scopus 로고
    • Energy requirements for conditioning fresh air and the long-term savings with a membrane-based energy recovery ventilator in Hong Kong
    • L.Z. Zhang, and J.L. Niu Energy requirements for conditioning fresh air and the long-term savings with a membrane-based energy recovery ventilator in Hong Kong Energy 26 2 2001 119 135
    • (2001) Energy , vol.26 , Issue.2 , pp. 119-135
    • Zhang, L.Z.1    Niu, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.