메뉴 건너뛰기




Volumn 40, Issue 5, 2012, Pages 820-824

Accuracy of recorded body temperature of critically ill patients related to measurement site: A prospective observational study

Author keywords

Bladder axillary; Body temperature; Critically ill; Measurement; Measurement site; Tympanic

Indexed keywords

AGED; ARTICLE; AXILLA TEMPERATURE; BLADDER TEMPERATURE; BODY TEMPERATURE; BODY TEMPERATURE MEASUREMENT; CRITICALLY ILL PATIENT; FEMALE; HUMAN; INDWELLING CATHETER; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; OBSERVATIONAL STUDY; PROSPECTIVE STUDY; PULMONARY ARTERY CATHETER; TYMPANIC TEMPERATURE;

EID: 84866541520     PISSN: 0310057X     EISSN: 14480271     Source Type: Journal    
DOI: 10.1177/0310057x1204000510     Document Type: Article
Times cited : (21)

References (14)
  • 1
    • 79960609688 scopus 로고    scopus 로고
    • Fever and fever management among intensive care patients with known or suspected infection: A multicentre prospective cohort study
    • Young P, Saxena M, Eastwood GM, Bellomo R, Beasley R. Fever and fever management among intensive care patients with known or suspected infection: a multicentre prospective cohort study. Crit Care Resusc 2011; 13:97-102.
    • (2011) Crit Care Resusc , vol.13 , pp. 97-102
    • Young, P.1    Saxena, M.2    Eastwood, G.M.3    Bellomo, R.4    Beasley, R.5
  • 3
  • 5
    • 0040675271 scopus 로고    scopus 로고
    • Monitoring urinary bladder temperature in the intensive care unit: State of the science
    • Fallis WM. Monitoring urinary bladder temperature in the intensive care unit: state of the science. Am J Crit Care 2002; 11:38-45.
    • (2002) Am J Crit Care , vol.11 , pp. 38-45
    • Fallis, W.M.1
  • 6
    • 0942289807 scopus 로고    scopus 로고
    • Estimating core temperature in infants and children after cardiac surgery: A comparison of six methods
    • Maxton FJ, Justin L, Gillies D. Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods. J Adv Nurs 2004; 45:214-222.
    • (2004) J Adv Nurs , vol.45 , pp. 214-222
    • Maxton, F.J.1    Justin, L.2    Gillies, D.3
  • 7
    • 0037348764 scopus 로고    scopus 로고
    • Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method
    • Lefrant JY, Muller L, Coussaye JE, Benbabaali M, Lebris C, Zeitoun N et al. Temperature measurement in intensive care patients: comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method. Intensive Care Med 2003; 29:414-418.
    • (2003) Intensive Care Med , vol.29 , pp. 414-418
    • Lefrant, J.Y.1    Muller, L.2    Coussaye, J.E.3    Benbabaali, M.4    Lebris, C.5    Zeitoun, N.6
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • B land JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 30344455282 scopus 로고    scopus 로고
    • An evaluation of tympanic thermometry in a paediatric emergency department
    • El-Radhi AS, Patel S. An evaluation of tympanic thermometry in a paediatric emergency department. Emerg Med J 2006; 23:40-41.
    • (2006) Emerg Med J , vol.23 , pp. 40-41
    • El-Radhi, A.S.1    Patel, S.2
  • 10
    • 38449105002 scopus 로고    scopus 로고
    • Accuracy and precision of noninvasive temperature measurement in adult intensive care patients
    • Lawson L, Bridges EJ, Ballou I, Eraker R, Greco S, Shively J et al. Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. Am J Crit Care 2007; 16:485-496.
    • (2007) Am J Crit Care , vol.16 , pp. 485-496
    • Lawson, L.1    Bridges, E.J.2    Ballou, I.3    Eraker, R.4    Greco, S.5    Shively, J.6
  • 11
    • 17844409554 scopus 로고    scopus 로고
    • Temperature measurement: Comparison of non-invasive methods used in adult critical care
    • Farnell S, Maxwell L, Tan S, Rhodes A, Philips B. Temperature measurement: comparison of non-invasive methods used in adult critical care. J Clin Nurs 2005; 14:632-639.
    • (2005) J Clin Nurs , vol.14 , pp. 632-639
    • Farnell, S.1    Maxwell, L.2    Tan, S.3    Rhodes, A.4    Philips, B.5
  • 12
    • 0031242183 scopus 로고    scopus 로고
    • Core body temperature measurement: A comparison of axilla, tympanic membrane and pulmonary artery blood temperature
    • Fulbrook P. Core body temperature measurement: a comparison of axilla, tympanic membrane and pulmonary artery blood temperature. Intensive Crit Care Nurs 1997; 13:266-272.
    • (1997) Intensive Crit Care Nurs , vol.13 , pp. 266-272
    • Fulbrook, P.1
  • 13
    • 80053304744 scopus 로고    scopus 로고
    • A systematic review of the accuracy of peripheral thermometry in estimating core temperatures among febrile critically ill patients
    • Jefferies S, Weatherall M, Young P, Beasley R. A systematic review of the accuracy of peripheral thermometry in estimating core temperatures among febrile critically ill patients. Crit Care Resusc 2011; 13:194-199.
    • (2011) Crit Care Resusc , vol.13 , pp. 194-199
    • Jefferies, S.1    Weatherall, M.2    Young, P.3    Beasley, R.4
  • 14
    • 14544273730 scopus 로고    scopus 로고
    • Accuracy of parents in measuring body temperature with a tympanic thermometer
    • Robinson JL, Jou H, Spady DW. Accuracy of parents in measuring body temperature with a tympanic thermometer. BMC Fam Pract 2005; 6:3.
    • (2005) BMC Fam Pract , vol.6 , pp. 3
    • Robinson, J.L.1    Jou, H.2    Spady, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.