A multi-pad electrode based functional electrical stimulation system for restoration of grasp

Author keywords

Functional electrical stimulation; Multi pad surface electrode; Selective stimulation

Indexed keywords

ALGORITHM; ARTICLE; CEREBROVASCULAR ACCIDENT; COMPUTER PROGRAM; CONVALESCENCE; ELECTRODE; ELECTROSTIMULATION; EQUIPMENT; FEEDBACK SYSTEM; FEMALE; FINGER; HAND; HAND STRENGTH; HEMIPLEGIA; HUMAN; INNERVATION; MALE; METHODOLOGY; MIDDLE AGED; MOTONEURON; MOVEMENT (PHYSIOLOGY); PHYSIOLOGY; POWER SUPPLY; PROSTHESIS; SKELETAL MUSCLE; TREATMENT OUTCOME; WIRELESS COMMUNICATION; WRIST;

EID: 84866534977     PISSN: None     EISSN: 17430003     Source Type: Journal    
DOI: 10.1186/1743-0003-9-66     Document Type: Article
Times cited : (131)

References (39)
  • 1
    • 75549096986 scopus 로고
    • An electrophysiologic splint for the hand
    • 14050723
    • An electrophysiologic splint for the hand. Long C, Arch Phys Med Rehabil 1963 44 499 503 14050723
    • (1963) Arch Phys Med Rehabil , vol.44 , pp. 499-503
    • Long, C.1
  • 2
    • 0015787499 scopus 로고
    • Proportionally controlled functional electrical stimulation of hand
    • 4269119
    • Proportionally controlled functional electrical stimulation of hand. Rebersek S, Vodovnik L, Arch Phys Med Rehabil 1973 54 378 4269119
    • (1973) Arch Phys Med Rehabil , vol.54 , pp. 378
    • Rebersek, S.1    Vodovnik, L.2
  • 4
    • 0016675208 scopus 로고
    • Electrophysiological orthosis for the upper extremity in hemiplegia: Feasibility study
    • 1081869
    • Electrophysiological orthosis for the upper extremity in hemiplegia: feasibility study. Merletti R, Acimovic R, Grobelnik S, Cvilak G, Arch Phys Med Rehabil 1975 56 507 1081869
    • (1975) Arch Phys Med Rehabil , vol.56 , pp. 507
    • Merletti, R.1    Acimovic, R.2    Grobelnik, S.3    Cvilak, G.4
  • 5
    • 78650925504 scopus 로고    scopus 로고
    • Electronic stimulators for surface neural prosthesis
    • 10.2298/JAC0802025B
    • Electronic stimulators for surface neural prosthesis. Broderick BJ, Breen PP, Olaighin G, Journal of Automatic Control 2008 18 25 33 10.2298/JAC0802025B
    • (2008) Journal of Automatic Control , vol.18 , pp. 25-33
    • Broderick, B.J.1    Breen, P.P.2    Olaighin, G.3
  • 6
    • 0035061148 scopus 로고    scopus 로고
    • Functional electrical stimulation by means of the 'Ness Handmaster Orthosis' in chronic stroke patients: An exploratory study
    • DOI 10.1191/026921501672937235
    • Functional electrical stimulation by means of the 'Ness Handmaster Orthosis' in chronic stroke patients: an exploratory study. Hendricks HT, IJzerman MJ, De Kroon JR, Zilvold G, Clin Rehabil 2001 15 217 220 10.1191/026921501672937235 11330767 (Pubitemid 32279578)
    • (2001) Clinical Rehabilitation , vol.15 , Issue.2 , pp. 217-220
    • Handricks, H.T.1    Ljzerman, M.J.2    DeKroon, J.R.3    Zilvold, G.4
  • 7
    • 69549111230 scopus 로고    scopus 로고
    • Electrical stimulation as a means for achieving recovery of function in stroke patients
    • Electrical stimulation as a means for achieving recovery of function in stroke patients. Popović DB, Sinkjær T, Popović MB, NeuroRehabil 2009 25 45 58
    • (2009) NeuroRehabil , vol.25 , pp. 45-58
    • Popović, D.B.1    Sinkjær, T.2    Popović, M.B.3
  • 8
    • 11144248953 scopus 로고    scopus 로고
    • Functional electrical stimulation improves motor recovery of the lower extremity and walking ability of subjects with first acute stroke: A randomized placebo-controlled trial
    • DOI 10.1161/01.STR.0000149623.24906.63
    • Functional electrical stimulation improves motor recovery of the lower extremity and walking ability of subjects with first acute stroke. Yan T, Hui-Chan CWY, Li LSW, Stroke 2005 36 80 85 10.1161/01.STR.0000149623.24906.63 15569875 (Pubitemid 40054179)
    • (2005) Stroke , vol.36 , Issue.1 , pp. 80-85
    • Yan, T.1    Hui-Chan, C.W.Y.2    Li, L.S.W.3
  • 9
    • 69549111230 scopus 로고    scopus 로고
    • Electrical stimulation as a means for achieving recovery of function in stroke patients
    • Electrical stimulation as a means for achieving recovery of function in stroke patients. Popović DB, Sinkjær T, Popović MB, NeuroRehabil 2009 25 45 58
    • (2009) NeuroRehabil , vol.25 , pp. 45-58
    • Popović, D.B.1    Sinkjær, T.2    Popović, M.B.3
  • 11
    • 0025254291 scopus 로고
    • Upper limb functions regained in quadriplegia: A hybrid computerized neuromuscular stimulation system
    • 2334287
    • Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Nathan RH, Ohry A, Arch Phys Med Rehabil 1990 71 415 2334287
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 415
    • Nathan, R.H.1    Ohry, A.2
  • 12
    • 0001780975 scopus 로고    scopus 로고
    • Handmaster NMS. Present technology and the next generation
    • Burnaby: Symposium IFESS Popovic D
    • Handmaster NMS. Present technology and the next generation. Nathan R, Proceedings of the 2nd Int Burnaby: Symposium IFESS, Popovic D, 1997 139 140
    • (1997) Proceedings of the 2nd Int , pp. 139-140
    • Nathan, R.1
  • 13
    • 0024761981 scopus 로고
    • An FNS-based system for generating upper limb function in the C4 quadriplegic
    • An FNS-based system for generating upper limb function in the C4 quadriplegic. Nathan RH, Med Biol Eng Comput 1989 27 549 556 10.1007/BF02441635 (Pubitemid 19274818)
    • (1989) Medical and Biological Engineering and Computing , vol.27 , Issue.6 , pp. 549-556
    • Nathan, R.H.1
  • 17
    • 70349473268 scopus 로고    scopus 로고
    • Array electrode design for transcutaneous electrical stimulation: A simulation study
    • 10.1016/j.medengphy.2009.05.006 19540788
    • Array electrode design for transcutaneous electrical stimulation: a simulation study. Kuhn A, Keller T, Micera S, Morari M, Med Eng Phys 2009 31 945 951 10.1016/j.medengphy.2009.05.006 19540788
    • (2009) Med Eng Phys , vol.31 , pp. 945-951
    • Kuhn, A.1    Keller, T.2    Micera, S.3    Morari, M.4
  • 18
    • 31144449199 scopus 로고    scopus 로고
    • An electrode configuration technique using an electrode matrix arrangement for FES-based upper arm rehabilitation systems
    • DOI 10.1016/j.medengphy.2005.03.010, PII S1350453305000767
    • An electrode configuration technique using an electrode matrix arrangement for FES-based upper arm rehabilitation systems. O'Dwyer SB, O'Keeffe DT, Coote S, Lyons GM, Med Eng Phys 2006 28 166 176 10.1016/j.medengphy.2005. 03.010 15936975 (Pubitemid 43129598)
    • (2006) Medical Engineering and Physics , vol.28 , Issue.2 , pp. 166-176
    • O'Dwyer, S.B.1    O'Keeffe, D.T.2    Coote, S.3    Lyons, G.M.4
  • 19
    • 24944440860 scopus 로고    scopus 로고
    • Multi-field surface electrode for selective electrical stimulation
    • DOI 10.1111/j.1525-1594.2005.29075.x
    • Multi Field Surface Electrode for Selective Electrical Stimulation. Popović Bijelić A, Bijelić G, Jorgovanović N, Bojanić D, Popović MB, Popović DB, Artif Organs 2005 29 448 452 10.1111/j.1525-1594.2005.29075.x 15926980 (Pubitemid 41602864)
    • (2005) Artificial Organs , vol.29 , Issue.6 , pp. 448-452
    • Popovic-Bijelic, A.1    Bijelic, G.2    Jorgovanovic, N.3    Bojanic, D.4    Popovic, M.B.5    Popovic, D.B.6
  • 20
    • 59349089487 scopus 로고    scopus 로고
    • Automatic determination of the optimal shape of a surface electrode: Selective stimulation
    • 10.1016/j.jneumeth.2008.12.003 19109996
    • Automatic determination of the optimal shape of a surface electrode: Selective stimulation. Popovic DB, Popovic MB, J Neurosci Methods 2009 178 174 181 10.1016/j.jneumeth.2008.12.003 19109996
    • (2009) J Neurosci Methods , vol.178 , pp. 174-181
    • Popovic, D.B.1    Popovic, M.B.2
  • 21
    • 77957674100 scopus 로고    scopus 로고
    • Distributed low frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation
    • 10.1002/mus.21736 20665516
    • Distributed low frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation. Malešević NM, Popović LZ, Schwirtlich L, Popović DB, Muscle Nerve 2010 42 556 562 10.1002/mus.21736 20665516
    • (2010) Muscle Nerve , vol.42 , pp. 556-562
    • Malešević, N.M.1    Popović, L.Z.2    Schwirtlich, L.3    Popović, D.B.4
  • 23
    • 84857964555 scopus 로고    scopus 로고
    • Spatially Distributed Sequential Stimulation Reduces Fatigue in Paralyzed Triceps Surae Muscles: A Case Study
    • 10.1111/j.1525-1594.2010.01195.x 21501192
    • Spatially Distributed Sequential Stimulation Reduces Fatigue in Paralyzed Triceps Surae Muscles: A Case Study. Nguyen R, Masani K, Micera S, Morari M, Popovic MR, Artif Organs 2011 35 1174 1180 10.1111/j.1525-1594.2010.01195.x 21501192
    • (2011) Artif Organs , vol.35 , pp. 1174-1180
    • Nguyen, R.1    Masani, K.2    Micera, S.3    Morari, M.4    Popovic, M.R.5
  • 26
    • 84872491813 scopus 로고    scopus 로고
    • Muscle twitch responses for shaping the multi-pad electrode for functional electrical stimulation
    • 10.2298/JAC1001053M
    • Muscle twitch responses for shaping the multi-pad electrode for functional electrical stimulation. Malešević N, Popović L, Bijelić G, Kvaščev G, J Automatic Control 2010 20 53 57 10.2298/JAC1001053M
    • (2010) J Automatic Control , vol.20 , pp. 53-57
    • Malešević, N.1    Popović, L.2    Bijelić, G.3    Kvaščev, G.4
  • 29
    • 0026107592 scopus 로고
    • A method to effect physiological recruitment order in electrically activated muscle
    • 10.1109/10.76384
    • A method to effect physiological recruitment order in electrically activated muscle. Fang ZP, Mortimer JT, Biomedical Engineering, IEEE Transactions on 1991 38 175 179 10.1109/10.76384
    • (1991) Biomedical Engineering, IEEE Transactions on , vol.38 , pp. 175-179
    • Fang, Z.P.1    Mortimer, J.T.2
  • 30
    • 0342902310 scopus 로고    scopus 로고
    • A novel stimulation pattern improves performance during repetitive dynamic contractions
    • DOI 10.1002/mus.1065
    • A novel stimulation pattern improves performance during repetitive dynamic contractions. Kebaetse MB, Lee SCK, Binder-Macleod SA, Muscle Nerve 2001 24 744 752 10.1002/mus.1065 11360257 (Pubitemid 32476520)
    • (2001) Muscle and Nerve , vol.24 , Issue.6 , pp. 744-752
    • Kebaetse, M.B.1    Lee, S.C.K.2    Binder-Macleod, S.A.3
  • 31
    • 34047201137 scopus 로고    scopus 로고
    • Effect of electrical stimulation pattern on the force responses of paralyzed human quadriceps muscles
    • DOI 10.1002/mus.20717
    • Effect of electrical stimulation pattern on the force responses of paralyzed human quadriceps muscles. Scott WB, Lee SCK, Johnston TE, Binkley J, Binder-Macleod SA, Muscle Nerve 2007 35 471 478 10.1002/mus.20717 17212347 (Pubitemid 46542967)
    • (2007) Muscle and Nerve , vol.35 , Issue.4 , pp. 471-478
    • Scott, W.B.1    Lee, S.C.K.2    Johnston, T.E.3    Binkley, J.4    Binder-Macleod, S.A.5
  • 33
    • 77952265655 scopus 로고    scopus 로고
    • Electrodes for transcutaneous (surface) electrical stimulation
    • 10.2298/JAC0802035K
    • Electrodes for transcutaneous (surface) electrical stimulation. Keller T, Kuhn A, J Automatic Control 2008 18 35 45 10.2298/JAC0802035K
    • (2008) J Automatic Control , vol.18 , pp. 35-45
    • Keller, T.1    Kuhn, A.2
  • 36
    • 79955961280 scopus 로고    scopus 로고
    • A durable, low-cost electrogoniometer for dynamic measurement of joint trajectories
    • 10.1016/j.medengphy.2010.12.008 23315799
    • A durable, low-cost electrogoniometer for dynamic measurement of joint trajectories. Wang PT, King CE, Do AH, Nenadic Z, Med Eng & Phys 2011 33 546 552 10.1016/j.medengphy.2010.12.008 23315799
    • (2011) Med Eng & Phys , vol.33 , pp. 546-552
    • Wang, P.T.1    King, C.E.2    Do, A.H.3    Nenadic, Z.4
  • 38
    • 33646357071 scopus 로고    scopus 로고
    • Twitch and tetanic properties of human thenar motor units paralyzed by chronic spinal cord injury
    • DOI 10.1152/jn.01339.2005
    • Twitch and tetanic properties of human thenar motor units paralyzed by chronic spinal cord injury. Häger-Ross CK, Klein CS, Thomas CK, J Neurophysiol 2006 96 165 174 10.1152/jn.01339.2005 16611836 (Pubitemid 44015351)
    • (2006) Journal of Neurophysiology , vol.96 , Issue.1 , pp. 165-174
    • Hager-Ross, C.K.1    Klein, C.S.2    Thomas, C.K.3
  • 39
    • 84872494188 scopus 로고    scopus 로고
    • 2012 http://www.youtube.com/watch?v=ocGWz1g8MP4&feature=plcp.
    • (2012)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.