메뉴 건너뛰기




Volumn 103, Issue 3, 2012, Pages 186-193

Application of the ADVIA cerebrospinal fluid assay to count residual red blood cells in blood components

Author keywords

Automated haematology analysers; Plasma; Platelet; Residual red blood cells; Transfusion

Indexed keywords

REAGENT; THROMBOCYTE CONCENTRATE;

EID: 84866462225     PISSN: 00429007     EISSN: 14230410     Source Type: Journal    
DOI: 10.1111/j.1423-0410.2012.01601.x     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 33744471382 scopus 로고    scopus 로고
    • A flow cytometric method for detection and enumeration of low-level, residual red blood cells in platelets and mononuclear cell products
    • Santana JM, Dumont LJ: A flow cytometric method for detection and enumeration of low-level, residual red blood cells in platelets and mononuclear cell products. Transfusion 2006; 46:966-972
    • (2006) Transfusion , vol.46 , pp. 966-972
    • Santana, J.M.1    Dumont, L.J.2
  • 2
    • 0037228546 scopus 로고    scopus 로고
    • The clinical implications of platelet transfusions associated with ABO or Rh(D) incompatibility
    • Lozano M, Cid J: The clinical implications of platelet transfusions associated with ABO or Rh(D) incompatibility. Transfus Med Rev 2003; 17:57-68
    • (2003) Transfus Med Rev , vol.17 , pp. 57-68
    • Lozano, M.1    Cid, J.2
  • 3
    • 0034494669 scopus 로고    scopus 로고
    • Is it necessary to administer anti-D to prevent RhD immunization after the transfusion of RhD-positive platelet concentrates?
    • Atoyebi W, Mundy N, Croxton T, et al.: Is it necessary to administer anti-D to prevent RhD immunization after the transfusion of RhD-positive platelet concentrates? Br J Haematol 2000; 111:980-983
    • (2000) Br J Haematol , vol.111 , pp. 980-983
    • Atoyebi, W.1    Mundy, N.2    Croxton, T.3
  • 4
    • 79958776269 scopus 로고    scopus 로고
    • Platelet transfusions from D+ donors to D- patients: a 10-year follow-up study of 1014 patients
    • Cid J, Carbasse G, Pereira A, et al.: Platelet transfusions from D+ donors to D- patients: a 10-year follow-up study of 1014 patients. Transfusion 2011; 51:1163-1169
    • (2011) Transfusion , vol.51 , pp. 1163-1169
    • Cid, J.1    Carbasse, G.2    Pereira, A.3
  • 5
    • 15944396932 scopus 로고    scopus 로고
    • Risk of Rh(D) alloimmunization after transfusion of platelets from D+ donors to D- recipients
    • Cid J, Lozano M: Risk of Rh(D) alloimmunization after transfusion of platelets from D+ donors to D- recipients. Transfusion 2005; 45:453-454
    • (2005) Transfusion , vol.45 , pp. 453-454
    • Cid, J.1    Lozano, M.2
  • 6
    • 0036480930 scopus 로고    scopus 로고
    • Absence of anti-D alloimmunization in hematologic patients after D-incompatible platelet transfusions
    • Cid J, Ortin X, Elies E, et al.: Absence of anti-D alloimmunization in hematologic patients after D-incompatible platelet transfusions. Transfusion 2002; 42:173-176
    • (2002) Transfusion , vol.42 , pp. 173-176
    • Cid, J.1    Ortin, X.2    Elies, E.3
  • 7
    • 0038307181 scopus 로고    scopus 로고
    • Probability of anti-D development in D- patients receiving D+ RBCs
    • Frohn C, Dumbgen L, Brand JM, et al.: Probability of anti-D development in D- patients receiving D+ RBCs. Transfusion. 2003; 43:893-898
    • (2003) Transfusion. , vol.43 , pp. 893-898
    • Frohn, C.1    Dumbgen, L.2    Brand, J.M.3
  • 8
    • 2342605961 scopus 로고    scopus 로고
    • Platelet transfusion in an infant leading to formation of anti-D: implications for immunoprophylaxis
    • Haspel RL, Walsh L, Sloan SR: Platelet transfusion in an infant leading to formation of anti-D: implications for immunoprophylaxis. Transfusion 2004; 44:747-749
    • (2004) Transfusion , vol.44 , pp. 747-749
    • Haspel, R.L.1    Walsh, L.2    Sloan, S.R.3
  • 11
    • 0035176632 scopus 로고    scopus 로고
    • Residual red cell and platelet content in WBC-reduced plasma measured by a novel flow cytometric method
    • Krailadsiri P, Seghatchian J: Residual red cell and platelet content in WBC-reduced plasma measured by a novel flow cytometric method. Transfus Apher Sci 2001; 24:279-286
    • (2001) Transfus Apher Sci , vol.24 , pp. 279-286
    • Krailadsiri, P.1    Seghatchian, J.2
  • 12
    • 0037103948 scopus 로고    scopus 로고
    • Improved flow cytometric method to enumerate residual cells: minimal linear detection limits for platelets, erythrocytes, and leukocytes
    • Pichler J, Printz D, Scharner D, et al.: Improved flow cytometric method to enumerate residual cells: minimal linear detection limits for platelets, erythrocytes, and leukocytes. Cytometry 2002; 50:231-237
    • (2002) Cytometry , vol.50 , pp. 231-237
    • Pichler, J.1    Printz, D.2    Scharner, D.3
  • 13
    • 84876454515 scopus 로고    scopus 로고
    • Canadian Blood Services: Canadian Blood Services, (accessed 18 October 2011).
    • Canadian Blood Services: Canadian Blood Services Visual Assessment Guide. Canadian Blood Services, 2009. http://www.transfusionmedicine.ca/sites/transfusionmedicine/files/PDF/VAG_en.pdf (accessed 18 October 2011).
    • (2009) Canadian Blood Services Visual Assessment Guide
  • 14
    • 2942604615 scopus 로고    scopus 로고
    • Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens
    • Mahieu S, Vertessen F, Van der Planken M: Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens. Clin Lab Haematol 2004; 26:195-199
    • (2004) Clin Lab Haematol , vol.26 , pp. 195-199
    • Mahieu, S.1    Vertessen, F.2    Van der Planken, M.3
  • 15
    • 84876452629 scopus 로고    scopus 로고
    • Siemens: ADVIA® 120 Cerebrospinal Fluid (CSF) Assay - Customer Bulletin (067D0014-01 Rev. A, 2002-10)..
    • Siemens: ADVIA® 120 Cerebrospinal Fluid (CSF) Assay - Customer Bulletin (067D0014-01 Rev. A, 2002-10). 2002.
    • (2002)
  • 16
    • 55349110645 scopus 로고    scopus 로고
    • Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production
    • Levin E, Culibrk B, Gyongyossy-Issa MI, et al.: Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production. Transfusion 2008; 48:2331-2337
    • (2008) Transfusion , vol.48 , pp. 2331-2337
    • Levin, E.1    Culibrk, B.2    Gyongyossy-Issa, M.I.3
  • 17
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part I
    • Passing H, Bablok W: A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part I. Clin Chem Lab Med 1983; 21:709-720
    • (1983) Clin Chem Lab Med , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0036483856 scopus 로고    scopus 로고
    • Immunoprophylaxis for D- patients receiving platelet transfusions from D+ donors?
    • Menitove JE: Immunoprophylaxis for D- patients receiving platelet transfusions from D+ donors? Transfusion 2002; 42:136-138
    • (2002) Transfusion , vol.42 , pp. 136-138
    • Menitove, J.E.1
  • 20
    • 0015244181 scopus 로고
    • Rh-incompatible platelet transfusions--risks and consequences of sensitizing immunosuppressed patients
    • Goldfinger D, McGinniss MH: Rh-incompatible platelet transfusions--risks and consequences of sensitizing immunosuppressed patients. N Engl J Med 1971; 284:942-944
    • (1971) N Engl J Med , vol.284 , pp. 942-944
    • Goldfinger, D.1    McGinniss, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.