메뉴 건너뛰기




Volumn 144, Issue 4, 2012, Pages 956-962

Combined proximal stent grafting plus distal bare metal stenting for management of aortic dissection: Superior to standard endovascular repair?

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ACUTE DISEASE; ACUTE KIDNEY FAILURE; ADULT; AORTA DISSECTION; ARTERY PERFUSION; ARTICLE; BARE METAL STENT; CHRONIC DISEASE; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; DESCENDING AORTA; DISEASE SEVERITY; ENDOVASCULAR ANEURYSM REPAIR; FEMALE; FOLLOW UP; HEART INFARCTION; HUMAN; INTESTINE ISCHEMIA; LIMB ISCHEMIA; MALE; MALPERFUSION SYNDROME; MORTALITY; OUTCOME ASSESSMENT; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; REOPERATION; SMOKING; SPINAL CORD ISCHEMIA; STROKE; SURGICAL TECHNIQUE; THORACIC AORTA ANEURYSM; TYPE A AORTIC DISSECTION; TYPE B AORTIC DISSECTION;

EID: 84866367295     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2012.07.007     Document Type: Article
Times cited : (45)

References (23)
  • 1
    • 0033586990 scopus 로고    scopus 로고
    • Endovascular stent-graft placement for the treatment of acute aortic dissection
    • M.D. Dake, N. Kato, R.S. Mitchell, C.P. Semba, M.K. Razavi, and T. Shimono Endovascular stent-graft placement for the treatment of acute aortic dissection N Engl J Med 340 1999 1546 1552
    • (1999) N Engl J Med , vol.340 , pp. 1546-1552
    • Dake, M.D.1    Kato, N.2    Mitchell, R.S.3    Semba, C.P.4    Razavi, M.K.5    Shimono, T.6
  • 6
    • 33751255665 scopus 로고    scopus 로고
    • Long-term survival in patients presenting with type A acute aortic dissection: Insights from the International Registry of Acute Aortic Dissection (IRAD)
    • T.T. Tsai, A. Evangelista, C.A. Nienaber, S. Trimarchi, U. Sechtem, and R. Fattori Long-term survival in patients presenting with type A acute aortic dissection: insights from the International Registry of Acute Aortic Dissection (IRAD) Circulation 114 1 Suppl 2006 I350 I356
    • (2006) Circulation , vol.114 , Issue.1 SUPPL.
    • Tsai, T.T.1    Evangelista, A.2    Nienaber, C.A.3    Trimarchi, S.4    Sechtem, U.5    Fattori, R.6
  • 7
    • 47049127772 scopus 로고    scopus 로고
    • Combining classic surgery with descending stent grafting for acute DeBakey type i dissection
    • H. Jakob, K. Tsagakis, P. Tossios, P. Massoudy, M. Thielmann, and T. Buck Combining classic surgery with descending stent grafting for acute DeBakey type I dissection Ann Thorac Surg 86 2008 95 101
    • (2008) Ann Thorac Surg , vol.86 , pp. 95-101
    • Jakob, H.1    Tsagakis, K.2    Tossios, P.3    Massoudy, P.4    Thielmann, M.5    Buck, T.6
  • 8
    • 67650729341 scopus 로고    scopus 로고
    • Antegrade thoracic stent grafting during repair of acute DeBakey i dissection prevents development of thoracoabdominal aortic aneurysms
    • A. Pochettino, W.T. Brinkman, P. Moeller, W.Y. Szeto, W. Moser, and K. Cornelius Antegrade thoracic stent grafting during repair of acute DeBakey I dissection prevents development of thoracoabdominal aortic aneurysms Ann Thorac Surg 88 2009 482 490
    • (2009) Ann Thorac Surg , vol.88 , pp. 482-490
    • Pochettino, A.1    Brinkman, W.T.2    Moeller, P.3    Szeto, W.Y.4    Moser, W.5    Cornelius, K.6
  • 9
    • 33645390163 scopus 로고    scopus 로고
    • Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection
    • N. Uchida, H. Ishihara, H. Shibamura, Y. Kyo, and M. Ozawa Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection J Thorac Cardiovasc Surg 131 2006 862 867
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 862-867
    • Uchida, N.1    Ishihara, H.2    Shibamura, H.3    Kyo, Y.4    Ozawa, M.5
  • 10
    • 84055212760 scopus 로고    scopus 로고
    • Combined proximal endografting with distal bare-metal stenting for management of aortic dissection
    • S.C. Hofferberth, P.T. Foley, A.E. Newcomb, K.K. Yap, M.Y. Yii, and I.K. Nixon Combined proximal endografting with distal bare-metal stenting for management of aortic dissection Ann Thorac Surg 93 2012 95 102
    • (2012) Ann Thorac Surg , vol.93 , pp. 95-102
    • Hofferberth, S.C.1    Foley, P.T.2    Newcomb, A.E.3    Yap, K.K.4    Yii, M.Y.5    Nixon, I.K.6
  • 11
    • 35448977635 scopus 로고    scopus 로고
    • Immediate "total" aortic true lumen expansion in type A and B acute aortic dissection after endovascular aortic endografting and GZSD bare stenting
    • P. Mossop, I. Nixon, J. Oakes, T.J. Devine, and C.S. McLachlan Immediate "total" aortic true lumen expansion in type A and B acute aortic dissection after endovascular aortic endografting and GZSD bare stenting J Thorac Cardiovasc Surg 134 2007 1360 1362
    • (2007) J Thorac Cardiovasc Surg , vol.134 , pp. 1360-1362
    • Mossop, P.1    Nixon, I.2    Oakes, J.3    Devine, T.J.4    McLachlan, C.S.5
  • 13
    • 37249091708 scopus 로고    scopus 로고
    • Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry
    • J. Buth, P.L. Harris, R. Hobo, R. van Eps, P. Cuypers, and L. Duijm Neurologic complications associated with endovascular repair of thoracic aortic pathology: incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry J Vasc Surg 46 2007 1103 1111
    • (2007) J Vasc Surg , vol.46 , pp. 1103-1111
    • Buth, J.1    Harris, P.L.2    Hobo, R.3    Van Eps, R.4    Cuypers, P.5    Duijm, L.6
  • 14
    • 0037221393 scopus 로고    scopus 로고
    • Percutaneous bare Z-stent implantation as an alternative to surgery for acute aortic dissection with visceral ischemia
    • N. Ito, T. Tsunoda, M. Nakamura, R. Iijima, K. Matsuda, and T. Suzuki Percutaneous bare Z-stent implantation as an alternative to surgery for acute aortic dissection with visceral ischemia Catheter Cardiovasc Interv 58 2003 95 100
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 95-100
    • Ito, N.1    Tsunoda, T.2    Nakamura, M.3    Iijima, R.4    Matsuda, K.5    Suzuki, T.6
  • 16
    • 33845411147 scopus 로고    scopus 로고
    • Provisional extension to induce complete attachment after stent-graft placement in type B aortic dissection: The PETTICOAT concept
    • C.A. Nienaber, S. Kische, T. Zeller, T.C. Rehders, H. Schneider, and B. Lorenzen Provisional extension to induce complete attachment after stent-graft placement in type B aortic dissection: the PETTICOAT concept J Endovasc Ther 13 2006 738 746
    • (2006) J Endovasc Ther , vol.13 , pp. 738-746
    • Nienaber, C.A.1    Kische, S.2    Zeller, T.3    Rehders, T.C.4    Schneider, H.5    Lorenzen, B.6
  • 17
    • 84857636525 scopus 로고    scopus 로고
    • Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design
    • J.V. Lombardi, R.P. Cambria, C.A. Nienaber, R. Chiesa, O. Teebken, and A. Lee Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design J Vasc Surg 55 2012 629 640
    • (2012) J Vasc Surg , vol.55 , pp. 629-640
    • Lombardi, J.V.1    Cambria, R.P.2    Nienaber, C.A.3    Chiesa, R.4    Teebken, O.5    Lee, A.6
  • 18
    • 29144516301 scopus 로고    scopus 로고
    • Novel measurement of relative aortic size predicts rupture of thoracic aortic aneurysms
    • R.R. Davies, A. Gallo, M.A. Coady, G. Tellides, D.M. Botta, and B. Burke Novel measurement of relative aortic size predicts rupture of thoracic aortic aneurysms Ann Thorac Surg 81 2006 169
    • (2006) Ann Thorac Surg , vol.81 , pp. 169
    • Davies, R.R.1    Gallo, A.2    Coady, M.A.3    Tellides, G.4    Botta, D.M.5    Burke, B.6
  • 21
    • 33847277077 scopus 로고    scopus 로고
    • Endovascular repair of acute type B aortic dissection: Long-term follow-up of true and false lumen diameter changes
    • M. Schoder, M. Czerny, M. Cejna, T. Rand, A. Stadler, and G.H. Sodeck Endovascular repair of acute type B aortic dissection: long-term follow-up of true and false lumen diameter changes Ann Thorac Surg 83 2007 1059 1066
    • (2007) Ann Thorac Surg , vol.83 , pp. 1059-1066
    • Schoder, M.1    Czerny, M.2    Cejna, M.3    Rand, T.4    Stadler, A.5    Sodeck, G.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.