메뉴 건너뛰기




Volumn 61, Issue 9, 2012, Pages 1011-1017

Comparison of continuous cardiac output measurement methods: Non-invasive estimated CCO using pulse wave transit time and CCO using thermodilution

Author keywords

Cardiac output (CO); CCO; esCCO; Pulmonary artery catheter; Pulse wave transit time; Thermodilution method

Indexed keywords

ACCURACY; ARTICLE; CARDIOVASCULAR PARAMETERS; CONTINUOUS CARDIAC OUTPUT; CONTROLLED STUDY; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; HEART OUTPUT MEASUREMENT; HOSPITAL ADMISSION; HUMAN; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; NON INVASIVE ESTIMATED CONTINUOUS CARDIAC OUTPUT; NON INVASIVE PROCEDURE; OPERATING ROOM; PULMONARY ARTERY CATHETER; PULSE WAVE TRANSIT TIME; THERMODILUTION;

EID: 84866340381     PISSN: 00214892     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (7)
  • 1
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac Output Determination From the Arterial Pressure Wave: Clinical Testing of a Novel Algorithm That Does Not Require Calibration
    • DOI 10.1053/j.jvca.2006.08.004, PII S1053077006003119
    • Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave : Clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007; 21 : 3-7. (Pubitemid 46199245)
    • (2007) Journal of Cardiothoracic and Vascular Anesthesia , vol.21 , Issue.1 , pp. 3-7
    • Manecke Jr., G.R.1    Auger, W.R.2
  • 2
    • 20944444823 scopus 로고    scopus 로고
    • A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors
    • Ishihara H, Okawa H, Tanabe K, Tsubo T, Sugo Y, Akiyama T, et al. A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18 : 313-20.
    • (2004) J Clin Monit Comput , vol.18 , pp. 313-320
    • Ishihara, H.1    Okawa, H.2    Tanabe, K.3    Tsubo, T.4    Sugo, Y.5    Akiyama, T.6
  • 3
    • 0014788560 scopus 로고
    • Estimation of stroke volume in the dog by a pulse contour method
    • Kouchoukos NT, Sheppard LC, McDonald DA. Estimation of stroke volume in the dog by a pulse contour method. Circ Res 1970; 26 : 611-23.
    • (1970) Circ Res , vol.26 , pp. 611-623
    • Kouchoukos, N.T.1    Sheppard, L.C.2    McDonald, D.A.3
  • 4
    • 0033497261 scopus 로고    scopus 로고
    • The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs
    • Ochiai R, Takeda J, Hosaka H, Sugo Y, Tanaka R, Soma T. The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs. J Clin Monit Comput 1999; 15 : 493-501. (Pubitemid 30311650)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.7-8 , pp. 493-501
    • Ochiai, R.1    Takeda, J.2    Hosaka, H.3    Sugo, Y.4    Tanaka, R.5    Soma, T.6
  • 5
    • 84866321842 scopus 로고    scopus 로고
    • Verification of a non-invasive continuous cardiac output measurement method based on the pulse-contour analysis combined with pulse wave transit time
    • esCCO Research Team
    • Yamada T, Sugo Y, Takeda J, esCCO Research Team. Verification of a non-invasive continuous cardiac output measurement method based on the pulse-contour analysis combined with pulse wave transit time. Eur J Anaesthesiol 2010 ; 27 Suppl 47 : 3AP5-9.
    • (2010) Eur J Anaesthesiol , vol.27 , Issue.SUPPL. 47
    • Yamada, T.1    Sugo, Y.2    Takeda, J.3
  • 6
    • 0035212066 scopus 로고    scopus 로고
    • Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients
    • Godje O, Friedl R, Hannekum A. Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients. Med Sci Monit 2001; 7 : 1344-50. (Pubitemid 33134675)
    • (2001) Medical Science Monitor , vol.7 , Issue.6 , pp. 1344-1350
    • Godje, O.1    Friedl, R.2    Hannekum, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.