Volumn 2012, Issue , 2012, Pages

Optimization of cannula visibility during ultrasound-guided subclavian vein catheterization, via a longitudinal approach, by implementing echogenic technology

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84866258757     PISSN: 20901305     EISSN: 20901313     Source Type: Journal    
DOI: 10.1155/2012/617149     Document Type: Article
Times cited : (10)

References (20)
  • 1
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: A meta- analysis of the literature
    • Randolph A. G., Cook D. J., Gonzales C. A., Pribble C. G., Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Critical Care Medicine 1996 24 12 2053 2058 2-s2.0-0029906824 (Pubitemid 26418901)
    • (1996) Critical Care Medicine , vol.24 , Issue.12 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3    Pribble, C.G.4
  • 2
    • 0027194079 scopus 로고
    • Ultrasound-assisted cannulation of the internal jugular vein: A prospective comparison to the external landmark-guided technique
    • Denys B. G., Uretsky B. F., Reddy S., Ultrasound-assisted cannulation of the internal jugular vein: a prospective comparison to the external landmark-guided technique. Circulation 1993 87 5 1557 1562 2-s2.0-0027194079 (Pubitemid 23133100)
    • (1993) Circulation , vol.87 , Issue.5 , pp. 1557-1562
    • Denys, B.G.1    Uretsky, B.F.2    Reddy, P.S.3
  • 3
    • 34250867431 scopus 로고    scopus 로고
    • Real-time ultrasound-guided catheterisation of the internal jugular vein: A prospective comparison with the landmark technique in critical care patients
    • DOI 10.1186/cc5101
    • Karakitsos D., Labropoulos N., de Groot E., Patrianakos A. P., Kouraklis G., Poularas J., Samonis G., Tsoutsos D. A., Konstadoulakis M. M., Karabinis A., Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Critical Care 2006 10 6, article no. R162 2-s2.0-34250867431 10.1186/cc5101 (Pubitemid 47087007)
    • (2006) Critical Care , vol.10 , Issue.6
    • Karakitsos, D.1    Labropoulos, N.2    De Groot, E.3    Patrianakos, A.P.4    Kouraklis, G.5    Poularas, J.6    Samonis, G.7    Tsoutsos, D.A.8    Konstadoulakis, M.M.9    Karabinis, A.10
  • 4
    • 0029582909 scopus 로고
    • Real-time ultrasound-guided central venous access via the subclavian approach
    • Lane P., Waldron R. J., Real-time ultrasound-guided central venous access via the subclavian approach. Anaesthesia and Intensive Care 1995 23 6 728 730 2-s2.0-0029582909 (Pubitemid 26015348)
    • (1995) Anaesthesia and Intensive Care , vol.23 , Issue.6 , pp. 728-730
    • Lane, P.1    Waldron, R.J.2
  • 5
    • 0031724390 scopus 로고    scopus 로고
    • Prospective, randomized trial of doppler-assisted subclavian vein catheterization
    • DOI 10.1001/archsurg.133.10.1089
    • Bold R. J., Winchester D. J., Madary A. R., Gregurich M. A., Mansfield P. F., Prospective, randomized trial of doppler-assisted subclavian vein catheterization. Archives of Surgery 1998 133 10 1089 1093 2-s2.0-0031724390 10.1001/archsurg.133.10.1089 (Pubitemid 28480474)
    • (1998) Archives of Surgery , vol.133 , Issue.10 , pp. 1089-1093
    • Bold, R.J.1    Winchester, D.J.2    Madary, A.R.3    Gregurich, M.A.4    Mansfield, P.F.5
  • 7
    • 84941817891 scopus 로고
    • Central vein catheterization. Failure and complication rates by three percutaneous approaches
    • DOI 10.1001/archinte.146.2.259
    • Sznajder J. I., Zveibil F. R., Bitterman H., Central vein catheterization. Failure and complication rates by three percutaneous approaches. Archives of Internal Medicine 1986 146 2 259 261 2-s2.0-0022479735 (Pubitemid 16018539)
    • (1986) Archives of Internal Medicine , vol.146 , Issue.2 , pp. 259-261
    • Sznajder, J.I.1    Zveibil, F.R.2    Bitterman, H.3
  • 8
    • 0028609605 scopus 로고
    • Complications and failures of subclavian-vein catheterization
    • 2-s2.0-0028609605 10.1056/NEJM199412293312602
    • Mansfield P. F., Hohn D. C., Fornage B. D., Gregurich M. A., Ota D. M., Complications and failures of subclavian-vein catheterization. New England Journal of Medicine 1994 331 26 1735 1738 2-s2.0-0028609605 10.1056/ NEJM199412293312602
    • (1994) New England Journal of Medicine , vol.331 , Issue.26 , pp. 1735-1738
    • Mansfield, P.F.1    Hohn, D.C.2    Fornage, B.D.3    Gregurich, M.A.4    Ota, D.M.5
  • 9
    • 35348947950 scopus 로고    scopus 로고
    • Ultrasound Characteristics of Needles for Regional Anesthesia
    • DOI 10.1016/j.rapm.2007.07.002, PII S1098733907005822
    • Maecken T., Zenz M., Grau T., Ultrasound characteristics of needles for regional anesthesia. Regional Anesthesia and Pain Medicine 2007 32 5 440 447 2-s2.0-35348947950 10.1016/j.rapm.2007.07.002 (Pubitemid 47600026)
    • (2007) Regional Anesthesia and Pain Medicine , vol.32 , Issue.5 , pp. 440-447
    • Maecken, T.1    Zenz, M.2    Grau, T.3
  • 10
    • 77952379191 scopus 로고    scopus 로고
    • Sonographic identification of needle tip by specialists and novices: A blinded comparison of 5 regional block needles in fresh human cadavers
    • 2-s2.0-77952379191 10.1097/AAP.0b013e3181d273da
    • Edgcombe H., Hocking G., Sonographic identification of needle tip by specialists and novices: a blinded comparison of 5 regional block needles in fresh human cadavers. Regional Anesthesia and Pain Medicine 2010 35 2 207 211 2-s2.0-77952379191 10.1097/AAP.0b013e3181d273da
    • (2010) Regional Anesthesia and Pain Medicine , vol.35 , Issue.2 , pp. 207-211
    • Edgcombe, H.1    Hocking, G.2
  • 11
    • 4544301513 scopus 로고    scopus 로고
    • Ultrasound visibility of needles used for regional nerve block: An in vitro study
    • DOI 10.1016/j.rapm.2004.07.001, PII S1098733904001993
    • Schafhalter-Zoppoth I., McCulloch C. E., Gray A. T., Ultrasound visibility of needles used for regional nerve block: an in vitro study. Regional Anesthesia and Pain Medicine 2004 29 5 480 488 2-s2.0-4544301513 10.1016/j.rapm.2004.07.001 (Pubitemid 39221896)
    • (2004) Regional Anesthesia and Pain Medicine , vol.29 , Issue.5 , pp. 480-488
    • Schafhalter-Zoppoth, I.1    McCulloch, C.E.2    Gray, A.T.3
  • 12
    • 34548236886 scopus 로고    scopus 로고
    • Investigation of a new echogenic needle for use with ultrasound peripheral nerve blocks
    • Deam R. K., Kluger R., Barrington M. J., McCutcheon C. A., Investigation of a new echogenic needle for use with ultrasound peripheral nerve blocks. Anaesthesia and Intensive Care 2007 35 4 582 586 2-s2.0-34548236886 (Pubitemid 47322325)
    • (2007) Anaesthesia and Intensive Care , vol.35 , Issue.4 , pp. 582-586
    • Deam, R.K.1    Kluger, R.2    Barrington, M.J.3    McCutcheon, C.A.4
  • 13
    • 0024409555 scopus 로고
    • Needle tip echogenicity. A study with real time ultrasound
    • Bondestam S., Kreula J., Needle tip echogenicity. A study with real time ultrasound. Investigative Radiology 1989 24 7 555 560 2-s2.0-0024409555 (Pubitemid 19176526)
    • (1989) Investigative Radiology , vol.24 , Issue.7 , pp. 555-560
    • Bondestam, S.1    Kreula, J.2
  • 14
    • 0344737614 scopus 로고    scopus 로고
    • Changes in Ultrasonographic Echogenicity and Visibility of Needles with Changes in Angles of Insonation
    • Nichols K., Wright L. B., Spencer T., Culp W. C., Changes in ultrasonographic echogenicity and visibility of needles with changes in angles of insonation. Journal of Vascular and Interventional Radiology 2003 14 12 1553 1557 2-s2.0-0344737614 (Pubitemid 37517632)
    • (2003) Journal of Vascular and Interventional Radiology , vol.14 , Issue.12 , pp. 1553-1557
    • Nichols, K.1    Wright, L.B.2    Spencer, T.3    Culp, W.C.4
  • 15
    • 79952135499 scopus 로고    scopus 로고
    • Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia
    • 2-s2.0-79952135499 10.1097/AAP.0b013e31820d4349
    • Hebard S., Hocking G., Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia. Regional Anesthesia and Pain Medicine 2011 36 2 185 189 2-s2.0-79952135499 10.1097/AAP.0b013e31820d4349
    • (2011) Regional Anesthesia and Pain Medicine , vol.36 , Issue.2 , pp. 185-189
    • Hebard, S.1    Hocking, G.2
  • 16
    • 0023368997 scopus 로고
    • An atraumatic universal needle for single-shot regional anesthesia: Clinical results and a 6 year trial in over 30,000 regional anesthesias
    • 2-s2.0-0023368997
    • Sprotte G., Schedel R., Pajunk H., Pajunk H., An atraumatic universal needle for single-shot regional anesthesia: clinical results and a 6 year trial in over 30,000 regional anesthesias Regional-Anaesthesie 1987 10 3 104 108 2-s2.0-0023368997
    • (1987) Regional-Anaesthesie , vol.10 , Issue.3 , pp. 104-108
    • Sprotte, G.1    Schedel, R.2    Pajunk, H.3    Pajunk, H.4
  • 17
    • 0031669011 scopus 로고    scopus 로고
    • MRI of central venous anatomy: Implications for central venous catheter insertion
    • Aslamy Z., Dewald C. L., Heffner J. E., MRI of central venous anatomy: implications for central venous catheter insertion. Chest 1998 114 3 820 826 2-s2.0-0031669011 (Pubitemid 28433747)
    • (1998) Chest , vol.114 , Issue.3 , pp. 820-826
    • Aslamy, Z.1    Dewald, C.L.2    Heffner, J.E.3
  • 20
    • 68249115032 scopus 로고    scopus 로고
    • An unseen danger: Frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance
    • 2-s2.0-68249115032 10.1097/CCM.0b013e3181a067d4
    • Blaivas M., Adhikari S., An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Critical Care Medicine 2009 37 8 2345 2349 2-s2.0-68249115032 10.1097/CCM.0b013e3181a067d4
    • (2009) Critical Care Medicine , vol.37 , Issue.8 , pp. 2345-2349
    • Blaivas, M.1    Adhikari, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.