-
1
-
-
0037030658
-
A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
-
Morice M.C., Serruys P.W., Sousa J.E., Fajadet J., Ban Hayashi E., Perin M., et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002, 346:1773-1780.
-
(2002)
N Engl J Med
, vol.346
, pp. 1773-1780
-
-
Morice, M.C.1
Serruys, P.W.2
Sousa, J.E.3
Fajadet, J.4
Ban Hayashi, E.5
Perin, M.6
-
2
-
-
20044366366
-
Thirty-day incidence and six-month clinical outcome of thrombotic stent occlusion after bare-metal, sirolimus, or paclitaxel stent implantation
-
Ong A.T., Hoye A., Aoki J., van Mieghem C.A., Rodriguez Granillo G.A., Sonnenschein K., et al. Thirty-day incidence and six-month clinical outcome of thrombotic stent occlusion after bare-metal, sirolimus, or paclitaxel stent implantation. J Am Coll Cardiol 2005, 45:947-953.
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 947-953
-
-
Ong, A.T.1
Hoye, A.2
Aoki, J.3
van Mieghem, C.A.4
Rodriguez Granillo, G.A.5
Sonnenschein, K.6
-
3
-
-
4544304750
-
Late coronary thrombosis after drug-eluting stent: stent vs. patient-driven prescription of aspirin-clopidogrel combination
-
Zimarino M., Renda G., Maddestra N., De Caterina R. Late coronary thrombosis after drug-eluting stent: stent vs. patient-driven prescription of aspirin-clopidogrel combination. Thromb Haemost 2004, 92:668-669.
-
(2004)
Thromb Haemost
, vol.92
, pp. 668-669
-
-
Zimarino, M.1
Renda, G.2
Maddestra, N.3
De Caterina, R.4
-
4
-
-
33745233024
-
Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk
-
Joner M., Finn A.V., Farb A., Mont E.K., Kolodgie F.D., Ladich E., et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 2006, 48:193-202.
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 193-202
-
-
Joner, M.1
Finn, A.V.2
Farb, A.3
Mont, E.K.4
Kolodgie, F.D.5
Ladich, E.6
-
5
-
-
29344432871
-
Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the research on adverse drug events and reports (RADAR) project
-
Nebeker J.R., Virmani R., Bennett C.L., Hoffman J.M., Samore M.H., Alvarez J., et al. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the research on adverse drug events and reports (RADAR) project. J Am Coll Cardiol 2006, 47:175-181.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 175-181
-
-
Nebeker, J.R.1
Virmani, R.2
Bennett, C.L.3
Hoffman, J.M.4
Samore, M.H.5
Alvarez, J.6
-
6
-
-
0037432294
-
Images in cardiovascular medicine. Sirolimus-eluting stent implanted in human coronary artery for 16 months: pathological findings
-
Guagliumi G., Farb A., Musumeci G., Valsecchi O., Tespili M., Motta T., et al. Images in cardiovascular medicine. Sirolimus-eluting stent implanted in human coronary artery for 16 months: pathological findings. Circulation 2003, 107:1340-1341.
-
(2003)
Circulation
, vol.107
, pp. 1340-1341
-
-
Guagliumi, G.1
Farb, A.2
Musumeci, G.3
Valsecchi, O.4
Tespili, M.5
Motta, T.6
-
7
-
-
36048993074
-
Medical applications of poly(styrene-block-isobutylene-block-styrene) (" SIBS" )
-
Pinchuk L., Wilson G.J., Barry J.J., Schoephoerster R.T., Parel J.M., Kennedy J.P. Medical applications of poly(styrene-block-isobutylene-block-styrene) (" SIBS" ). Biomaterials 2008, 29:448-460.
-
(2008)
Biomaterials
, vol.29
, pp. 448-460
-
-
Pinchuk, L.1
Wilson, G.J.2
Barry, J.J.3
Schoephoerster, R.T.4
Parel, J.M.5
Kennedy, J.P.6
-
9
-
-
0035834853
-
Sulfonation of poly(ether ether ketone) (PEEK): kinetic study and characterization
-
Huang R.Y.M., Shao P.H., Burns C.M., Feng X. Sulfonation of poly(ether ether ketone) (PEEK): kinetic study and characterization. J Appl Polym Sci 2001, 82:2651-2660.
-
(2001)
J Appl Polym Sci
, vol.82
, pp. 2651-2660
-
-
Huang, R.Y.M.1
Shao, P.H.2
Burns, C.M.3
Feng, X.4
-
10
-
-
1942472672
-
Preparation and characterization of sulfonated polyetherimide/polyetherimide blend membranes
-
Shen L.Q., Xu Z.K., Yang Q., Sun H.L., Wang S.Y., Xu Y.Y. Preparation and characterization of sulfonated polyetherimide/polyetherimide blend membranes. J Appl Polym Sci 2004, 92:1709-1715.
-
(2004)
J Appl Polym Sci
, vol.92
, pp. 1709-1715
-
-
Shen, L.Q.1
Xu, Z.K.2
Yang, Q.3
Sun, H.L.4
Wang, S.Y.5
Xu, Y.Y.6
-
11
-
-
0346461550
-
Synthesis and characterization of sulfonated poly(ether ether ketone) for proton exchange membranes
-
Xing P.X., Robertson G.P., Guiver M.D., Mikhailenko S.D., Wang K.P., Kaliaguine S. Synthesis and characterization of sulfonated poly(ether ether ketone) for proton exchange membranes. J Memb Sci 2004, 229:95-106.
-
(2004)
J Memb Sci
, vol.229
, pp. 95-106
-
-
Xing, P.X.1
Robertson, G.P.2
Guiver, M.D.3
Mikhailenko, S.D.4
Wang, K.P.5
Kaliaguine, S.6
-
12
-
-
1842473810
-
Sulfonation and characterization of poly (styrene-isobutylene-styrene) triblock copolymers at high ion-exchange capacities
-
Elabd Y.A., Napadensky E. Sulfonation and characterization of poly (styrene-isobutylene-styrene) triblock copolymers at high ion-exchange capacities. Polymer 2004, 45:3037-3043.
-
(2004)
Polymer
, vol.45
, pp. 3037-3043
-
-
Elabd, Y.A.1
Napadensky, E.2
-
13
-
-
33750531239
-
Platelet adsorption and hemolytic properties of liquid crystal/composite polymers
-
Shih M.F., Shau M.D., Chang M.Y., Chiou S.K., Chang J.K., Cherng J.Y. Platelet adsorption and hemolytic properties of liquid crystal/composite polymers. Int J Pharm 2006, 327:117-125.
-
(2006)
Int J Pharm
, vol.327
, pp. 117-125
-
-
Shih, M.F.1
Shau, M.D.2
Chang, M.Y.3
Chiou, S.K.4
Chang, J.K.5
Cherng, J.Y.6
-
14
-
-
3042855340
-
In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices
-
Alexis F., Venkatraman S.S., Rath S.K., Boey F. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices. J Control Release 2004, 98:67-74.
-
(2004)
J Control Release
, vol.98
, pp. 67-74
-
-
Alexis, F.1
Venkatraman, S.S.2
Rath, S.K.3
Boey, F.4
-
15
-
-
0026515530
-
Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model
-
Schwartz R.S., Huber K.C., Murphy J.G., Edwards W.D., Camrud A.R., Vlietstra R.E., et al. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol 1992, 19:267-274.
-
(1992)
J Am Coll Cardiol
, vol.19
, pp. 267-274
-
-
Schwartz, R.S.1
Huber, K.C.2
Murphy, J.G.3
Edwards, W.D.4
Camrud, A.R.5
Vlietstra, R.E.6
-
16
-
-
0031885670
-
In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia
-
Kornowski R., Hong M.K., Tio F.O., Bramwell O., Wu H., Leon M.B. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. J Am Coll Cardiol 1998, 31:224-230.
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 224-230
-
-
Kornowski, R.1
Hong, M.K.2
Tio, F.O.3
Bramwell, O.4
Wu, H.5
Leon, M.B.6
-
17
-
-
0019570085
-
Sensitivity of erythrocytes from various species to in vitro hemolyzation
-
Wennberg A., Hensten-Pettersen A. Sensitivity of erythrocytes from various species to in vitro hemolyzation. J Biomed Mater Res 1981, 15:433-435.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 433-435
-
-
Wennberg, A.1
Hensten-Pettersen, A.2
-
18
-
-
33745436151
-
The Taxus drug-eluting stent: a new paradigm in controlled drug delivery
-
Kamath K.R., Barry J.J., Miller K.M. The Taxus drug-eluting stent: a new paradigm in controlled drug delivery. Adv Drug Deliv Rev 2006, 58:412-436.
-
(2006)
Adv Drug Deliv Rev
, vol.58
, pp. 412-436
-
-
Kamath, K.R.1
Barry, J.J.2
Miller, K.M.3
-
19
-
-
0035940374
-
Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up
-
Sousa J.E., Costa M.A., Abizaid A.C., Rensing B.J., Abizaid A.S., Tanajura L.F., et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation 2001, 104:2007-2011.
-
(2001)
Circulation
, vol.104
, pp. 2007-2011
-
-
Sousa, J.E.1
Costa, M.A.2
Abizaid, A.C.3
Rensing, B.J.4
Abizaid, A.S.5
Tanajura, L.F.6
-
20
-
-
6944237687
-
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
-
McFadden E.P., Stabile E., Regar E., Cheneau E., Ong A.T., Kinnaird T., et al. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet 2004, 364:1519-1521.
-
(2004)
Lancet
, vol.364
, pp. 1519-1521
-
-
McFadden, E.P.1
Stabile, E.2
Regar, E.3
Cheneau, E.4
Ong, A.T.5
Kinnaird, T.6
-
21
-
-
33646252464
-
Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings
-
Kotani J., Awata M., Nanto S., Uematsu M., Oshima F., Minamiguchi H., et al. Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings. J Am Coll Cardiol 2006, 47:2108-2111.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 2108-2111
-
-
Kotani, J.1
Awata, M.2
Nanto, S.3
Uematsu, M.4
Oshima, F.5
Minamiguchi, H.6
-
22
-
-
10744229988
-
Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
-
Virmani R., Guagliumi G., Farb A., Musumeci G., Grieco N., Motta T., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 2004, 109:701-705.
-
(2004)
Circulation
, vol.109
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
Musumeci, G.4
Grieco, N.5
Motta, T.6
-
23
-
-
53149141718
-
Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial
-
Windecker S., Serruys P.W., Wandel S., Buszman P., Trznadel S., Linke A., et al. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet 2008, 372:1163-1173.
-
(2008)
Lancet
, vol.372
, pp. 1163-1173
-
-
Windecker, S.1
Serruys, P.W.2
Wandel, S.3
Buszman, P.4
Trznadel, S.5
Linke, A.6
-
25
-
-
77950893573
-
Comparison of the incidence of late stent thrombosis after implantation of different drug-eluting stents in the real world coronary heart disease patients: three-year follow-up results
-
Chen J.L., Gao L.J., Yang Y.J., Li J.J., Qiao S.B., Xu B., et al. Comparison of the incidence of late stent thrombosis after implantation of different drug-eluting stents in the real world coronary heart disease patients: three-year follow-up results. Chin Med J (Engl) 2010, 123:778-781.
-
(2010)
Chin Med J (Engl)
, vol.123
, pp. 778-781
-
-
Chen, J.L.1
Gao, L.J.2
Yang, Y.J.3
Li, J.J.4
Qiao, S.B.5
Xu, B.6
-
26
-
-
77950910232
-
Comparison of long-term clinical outcome after successful implantation of firebird sirolimus- and Taxus paclitaxel-eluting stents in Chinese population: analysis of a large single center registry
-
Dou K.F., Xu B., Yang Y.J., Chen J.L., Qiao S.B., Wang Y., et al. Comparison of long-term clinical outcome after successful implantation of firebird sirolimus- and Taxus paclitaxel-eluting stents in Chinese population: analysis of a large single center registry. Chin Med J (Engl) 2010, 123:810-815.
-
(2010)
Chin Med J (Engl)
, vol.123
, pp. 810-815
-
-
Dou, K.F.1
Xu, B.2
Yang, Y.J.3
Chen, J.L.4
Qiao, S.B.5
Wang, Y.6
-
27
-
-
36749068272
-
Overlapping paclitaxel-eluting stents: long-term effects in a porcine coronary artery model
-
Wilson G.J., Polovick J.E., Huibregtse B.A., Poff B.C. Overlapping paclitaxel-eluting stents: long-term effects in a porcine coronary artery model. Cardiovasc Res 2007, 76:361-372.
-
(2007)
Cardiovasc Res
, vol.76
, pp. 361-372
-
-
Wilson, G.J.1
Polovick, J.E.2
Huibregtse, B.A.3
Poff, B.C.4
|