메뉴 건너뛰기




Volumn 53, Issue 9, 2012, Pages 1415-1426

Workflow and scan protocol considerations for integrated whole-body PET/MRI in oncology

Author keywords

Hybrid imaging; Oncology; PET MR; Workflow

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84866147407     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.112.109348     Document Type: Review
Times cited : (102)

References (33)
  • 1
    • 0030173128 scopus 로고    scopus 로고
    • A system to obtain radiotracer uptake data simultaneously with NMR spectra in a high field magnet
    • Buchanan M, Marsden PK, Mielke CH, Garlick PB. A system to obtain radiotracer uptake data simultaneously with NMR spectra in a high field magnet. IEEE Trans Nucl Sci. 1996;43:2044-2048.
    • (1996) IEEE Trans Nucl Sci , vol.43 , pp. 2044-2048
    • Buchanan, M.1    Marsden, P.K.2    Mielke, C.H.3    Garlick, P.B.4
  • 2
    • 0030732855 scopus 로고    scopus 로고
    • PET and NMR dual acquisition (PANDA): Applications to isolated, perfused rat hearts
    • Garlick PB, Marsden PK, Cave AC, et al. PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts. NMR Biomed. 1997;10:138-142.
    • (1997) NMR Biomed , vol.10 , pp. 138-142
    • Garlick, P.B.1    Marsden, P.K.2    Cave, A.C.3
  • 3
  • 4
    • 51549120220 scopus 로고    scopus 로고
    • Simultaneous MR/PET imaging of the human brain: Feasibility study
    • Schlemmer HP, Pichler BJ, Schmand M, et al. Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology. 2008;248:1028-1035.
    • (2008) Radiology , vol.248 , pp. 1028-1035
    • Schlemmer, H.P.1    Pichler, B.J.2    Schmand, M.3
  • 5
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system
    • Zaidi H, Ojha N, Morich M, et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol. 2011;56:3091-3106.
    • (2011) Phys Med Biol , vol.56 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3
  • 6
    • 84860889359 scopus 로고    scopus 로고
    • First clinical experience of integrated whole-body PET/MR: Comparison to PET/CT in patients with oncological diagnoses
    • Drzezga A, Souvatzoglou M, Eiber M, et al. First clinical experience of integrated whole-body PET/MR: comparison to PET/CT in patients with oncological diagnoses. J Nucl Med. 2012;53:845-855.
    • (2012) J Nucl Med , vol.53 , pp. 845-855
    • Drzezga, A.1    Souvatzoglou, M.2    Eiber, M.3
  • 8
    • 77952095948 scopus 로고    scopus 로고
    • Integrating imaging modalities: What makes sense from a workflow perspective?
    • von Schulthess GK, Burger C. Integrating imaging modalities: what makes sense from a workflow perspective? Eur J Nucl Med Mol Imaging. 2010;37:980-990.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 980-990
    • Von Schulthess, G.K.1    Burger, C.2
  • 9
    • 60649120728 scopus 로고    scopus 로고
    • PET and MRI in cardiac imaging: From validation studies to integrated applications
    • Nekolla SG, Martinez-Möller A, Saraste A. PET and MRI in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36(suppl):S121-S130.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL.
    • Nekolla, S.G.1    Martinez-Möller, A.2    Saraste, A.3
  • 10
    • 60549093826 scopus 로고    scopus 로고
    • The potential of PET/MR for brain imaging
    • Heiss WD. The potential of PET/MR for brain imaging. Eur J Nucl Med Mol Imaging. 2009;36(suppl):S105-S112.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL.
    • Heiss, W.D.1
  • 11
    • 0037714158 scopus 로고    scopus 로고
    • Clinical 18F-FDG oncology patient preparation techniques
    • Hamblen SM, Lowe VJ. Clinical 18F-FDG oncology patient preparation techniques. J Nucl Med Technol. 2003;31:3-7.
    • (2003) J Nucl Med Technol , vol.31 , pp. 3-7
    • Hamblen, S.M.1    Lowe, V.J.2
  • 12
    • 40249083936 scopus 로고    scopus 로고
    • Whole-body PET imaging methods
    • Valk PE, Bailey DL, Townsend DW, Maisey MN, eds. 1st ed. New York, NY: Springer
    • Schreve PD. Whole-body PET imaging methods. In: Valk PE, Bailey DL, Townsend DW, Maisey MN, eds. Positron Emission Tomography: Basic Science and Clinical Practice. 1st ed. New York, NY: Springer, 2004;481-493.
    • (2004) Positron Emission Tomography: Basic Science and Clinical Practice , pp. 481-493
    • Schreve, P.D.1
  • 13
    • 0029776067 scopus 로고    scopus 로고
    • Skeletal muscle uptake of fluorine-18-FDG: Effect of oral diazepam
    • Barrington SF, Maisey MN. Skeletal muscle uptake of fluorine-18-FDG: effect of oral diazepam. J Nucl Med. 1996;37:1127-1129.
    • (1996) J Nucl Med , vol.37 , pp. 1127-1129
    • Barrington, S.F.1    Maisey, M.N.2
  • 14
    • 79953691789 scopus 로고    scopus 로고
    • The effect of patient positioning aids on PET quantification in PET/MR imaging
    • Mantlik F, Hofmann M, Werner MK, et al. The effect of patient positioning aids on PET quantification in PET/MR imaging. Eur J Nucl Med Mol Imaging. 2011;38:920-929.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 920-929
    • Mantlik, F.1    Hofmann, M.2    Werner, M.K.3
  • 15
    • 84861632676 scopus 로고    scopus 로고
    • Hybrid PET/MRI imaging with continuous table motion
    • Braun H, Ziegler S, Paulus DH, Quick HH. Hybrid PET/MRI imaging with continuous table motion. Med Phys. 2012;39:2735-2745.
    • (2012) Med Phys , vol.39 , pp. 2735-2745
    • Braun, H.1    Ziegler, S.2    Paulus, D.H.3    Quick, H.H.4
  • 16
    • 34548104447 scopus 로고    scopus 로고
    • Is MR-guided attenuation correction a viable option for dual-modality PET/MR imaging?
    • Zaidi H. Is MR-guided attenuation correction a viable option for dual-modality PET/MR imaging? Radiology. 2007;244:639-642.
    • (2007) Radiology , vol.244 , pp. 639-642
    • Zaidi, H.1
  • 17
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
    • Hofmann M, Pichler B, Schölkopf B, Beyer T. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging. 2009;36(suppl 1):S93-S104.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Hofmann, M.1    Pichler, B.2    Schölkopf, B.3    Beyer, T.4
  • 18
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
    • Martinez-Möller A, Souvatzoglou M, Delso G. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50:520-526.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3
  • 19
    • 80455149956 scopus 로고    scopus 로고
    • Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions
    • Eiber M, Martinez-Mö ller A, Souvatzoglou M, et al. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions. Eur J Nucl Med Mol Imaging. 2011;38:1691-1701.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 1691-1701
    • Eiber, M.1    Martinez-Möller, A.2    Souvatzoglou, M.3
  • 20
    • 79551523276 scopus 로고    scopus 로고
    • Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    • Schulz V, Torres-Espallardo I, Renisch S, et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging. 2011;38:138-152.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 138-152
    • Schulz, V.1    Torres-Espallardo, I.2    Renisch, S.3
  • 21
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • Catana C, van der Kouwe A, Benner T, et al. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med. 2010;51:1431-1438.
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Van Der Kouwe, A.2    Benner, T.3
  • 22
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- and atlas-based methods
    • Hofmann M, Bezrukov I, Mantlik F, et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med. 2011;52:1392-1399.
    • (2011) J Nucl Med , vol.52 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3
  • 23
    • 84865744034 scopus 로고    scopus 로고
    • Simulation of a MR-PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction
    • November 10, [Epub ahead of print]
    • Eiber M, Souvatzoglou M, Pickhard A, et al. Simulation of a MR-PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction. Eur J Radiol. November 10, 2011 [Epub ahead of print].
    • (2011) Eur J Radiol
    • Eiber, M.1    Souvatzoglou, M.2    Pickhard, A.3
  • 24
    • 79959710279 scopus 로고    scopus 로고
    • 18F-FDG PET/CT for the detection of distant metastases in high-risk patients with head and neck squamous cell carcinoma
    • 18F-FDG PET/CT for the detection of distant metastases in high-risk patients with head and neck squamous cell carcinoma. Oral Oncol. 2011;47:653-659.
    • (2011) Oral Oncol , vol.47 , pp. 653-659
    • Haerle, S.K.1    Schmid, D.T.2    Ahmad, N.3    Hany, T.F.4    Stoeckli, S.J.5
  • 25
    • 84857425240 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging for liver lesion characterization: A critical look
    • Taouli B. Diffusion-weighted MR imaging for liver lesion characterization: a critical look. Radiology. 2012;262:378-380.
    • (2012) Radiology , vol.262 , pp. 378-380
    • Taouli, B.1
  • 26
    • 84858288737 scopus 로고    scopus 로고
    • Detection and classification of focal liver lesions in patients with colorectal cancer: Retrospective comparison of diffusion-weighted MR imaging and multi-slice CT
    • Eiber M, Fingerle AA, Brügel M, et al. Detection and classification of focal liver lesions in patients with colorectal cancer: retrospective comparison of diffusion-weighted MR imaging and multi-slice CT. Eur J Radiol. 2012;81:683-691.
    • (2012) Eur J Radiol , vol.81 , pp. 683-691
    • Eiber, M.1    Fingerle, A.A.2    Brügel, M.3
  • 31
  • 32
    • 34047230826 scopus 로고    scopus 로고
    • Artifacts from misaligned CT in cardiac perfusion PET/CT studies: Frequency, effects, and potential solutions
    • Martinez-Möller A, Souvatzoglou M, Navab N, Schwaiger M, Nekolla SG. Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions. J Nucl Med. 2007;48:188-193.
    • (2007) J Nucl Med , vol.48 , pp. 188-193
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Navab, N.3    Schwaiger, M.4    Nekolla, S.G.5
  • 33
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • Keereman V, Van Holen R, Mollet P, Candenberghe S. The effect of errors in segmented attenuation maps on PET quantification. Med Phys. 2011;38:6010-6019.
    • (2011) Med Phys , vol.38 , pp. 6010-6019
    • Keereman, V.1    Van Holen, R.2    Mollet, P.3    Candenberghe, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.