Volumn 39, Issue 9, 2012, Pages 5479-5487

Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers

Author keywords

4D dose calculation; Cyberknife; Monte Carlo dose calculation; stereotactic body radiotherapy

Indexed keywords

BIOLOGICAL ORGANS; DEFORMATION; DISEASES; DOSIMETRY; HISTOLOGY; MONTE CARLO METHODS; PATIENT MONITORING; RADIOTHERAPY; TRANSMISSION CONTROL PROTOCOL; TUMORS;

EID: 84866070618     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4739249     Document Type: Article
Times cited : (20)

References (26)
  • 1
    • 84857804807 scopus 로고    scopus 로고
    • The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery
    • 10.1118/1.3685583
    • M. Falk, T. Larsson, P. Keall, B. C. Cho, M. Aznar, S. Korreman, P. Poulsen, and P. M. a. Rosenschold, The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery., Med. Phys. 39, 1588-1594 (2012). 10.1118/1.3685583
    • (2012) Med. Phys. , vol.39 , pp. 1588-1594
    • Falk, M.1    Larsson, T.2    Keall, P.3    Cho, B.C.4    Aznar, M.5    Korreman, S.6    Poulsen, P.7    Rosenschold, P.M.A.8
  • 3
    • 34347390456 scopus 로고    scopus 로고
    • Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study
    • DOI 10.1118/1.2739811
    • Y. Seppenwoolde, R. Berbeco, S. Nishioka, H. Shirato, and B. Heijmen, Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study., Med. Phys. 34, 2774-2784 (2007). 10.1118/1.2739811 (Pubitemid 47019797)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2774-2784
    • Seppenwoolde, Y.1    Berbeco, R.I.2    Nishioka, S.3    Shirato, H.4    Heijmen, B.5
  • 4
    • 64049103804 scopus 로고    scopus 로고
    • Clinical accuracy of the respiratory tumor tracking system of the Cyberknife: Assessment by analysis of log files
    • 10.1016/j.ijrob2008.12.041
    • M. Hoogenman, J.-B. Prevost, J. Nuyttens, J. Poll, P. Levendag, and B. Heijmen, Clinical accuracy of the respiratory tumor tracking system of the Cyberknife: Assessment by analysis of log files., Int. J. Radiat. Oncol. Biol. Phys. 74, 297-303 (2009). 10.1016/j.ijrobp.2008.12.041
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.74 , pp. 297-303
    • Hoogenman, M.1    Prevost, J.-B.2    Nuyttens, J.3    Poll, J.4    Levendag, P.5    Heijmen, B.6
  • 7
    • 41449087578 scopus 로고    scopus 로고
    • Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study
    • DOI 10.1118/1.2842074
    • E. Nioutsikou, Y. Seppenwoolde, J. Symonds-Tayler, B. Heijmen, P. Evans, and S. Webb, Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study., Med. Phys. 35, 1232-1240 (2008). 10.1118/1.2842074 (Pubitemid 351457488)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1232-1240
    • Nioutsikou, E.1    Seppenwoolde, Y.2    Symonds-Tayler, J.R.N.3    Heijmen, B.4    Evans, P.5    Webb, S.6
  • 8
    • 77950559885 scopus 로고    scopus 로고
    • Comparison of planned dose distributions calculated by Monte Carlo and Ray-Trace algorithms for the treatment of lung tumors with CyberKnife: A preliminary study in 33 Patients
    • 10.1016/j.ijrob2009.08.001
    • E. E. Wilcox, G. M. Daskalov, H. Lincoln, R. C. Shumway, B. M. Kaplan, and J. M. Colasanto, Comparison of planned dose distributions calculated by Monte Carlo and Ray-Trace algorithms for the treatment of lung tumors with CyberKnife: A preliminary study in 33 Patients., Int. J. Radiat. Oncol. Biol. Phys. 77, 277-284 (2010). 10.1016/j.ijrobp.2009.08.001
    • (2010) Int. J. Radiat. Oncol. Biol. Phys. , vol.77 , pp. 277-284
    • Wilcox, E.E.1    Daskalov, G.M.2    Lincoln, H.3    Shumway, R.C.4    Kaplan, B.M.5    Colasanto, J.M.6
  • 10
    • 33748852757 scopus 로고    scopus 로고
    • Use of motion tracking in stereotactic body radiotherapy: Evaluation of uncertainty in off-target dose distribution and optimization strategies
    • DOI 10.1080/02841860600908962, PII L674671041037W61
    • F. Casamassima, C. Cavedon, P. Francescon, J. Stancanello, M. Avanzo, S. Cora, and P. Scalchi, Use of motion tracking in stereotactic body radiotherapy: Evaluation of uncertainty in off-target dose distribution and optimization strategies., Acta Oncol. 45, 943-947 (2006). 10.1080/02841860600908962 (Pubitemid 44423143)
    • (2006) Acta Oncologica , vol.45 , Issue.7 , pp. 943-947
    • Casamassima, F.1    Cavedon, C.2    Francescon, P.3    Stancanello, J.4    Avanzo, M.5    Cora, S.6    Scalchi, P.7
  • 11
    • 84866112578 scopus 로고    scopus 로고
    • 4D treatment optimization and planning for radiosurgery with respiratory motion tracking
    • in, edited by J. J. Kresl, J. D. Luketich, L. Papiez, R. Timmerman, and R. A. Schulz (Springer, Berlin)
    • J. West, J. Park, J. Dooley, and C. Maurer, 4D treatment optimization and planning for radiosurgery with respiratory motion tracking., in Treating Tumors that Move with Respiration, edited by, J. J. Kresl, J. D. Luketich, L. Papiez, R. Timmerman, and, R. A. Schulz, (Springer, Berlin, 2007), pp. 249-264.
    • (2007) Treating Tumors That Move with Respiration , pp. 249-264
    • West, J.1    Park, J.2    Dooley, J.3    Maurer, C.4
  • 14
    • 44449122864 scopus 로고    scopus 로고
    • Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
    • DOI 10.1118/1.2912179
    • E. Wilcox and G. Daskalov, Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6MV photon fields smaller than 4cm produced by Cyberknife., Med. Phys. 35, 2259-2266 (2008). 10.1118/1.2912179 (Pubitemid 351752943)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2259-2266
    • Wilcox, E.E.1    Daskalov, G.M.2
  • 15
    • 0033045661 scopus 로고    scopus 로고
    • Estimation of tumor control probability model parameters from 3-D dose distributions of non-small cell lung cancer patients
    • DOI 10.1016/S0169-5002(99)00019-7, PII S0169500299000197
    • M. Martel, R. Ten Haken, M. Hazuka, M. Kessler, M. Strawderman, A. Turrisi, T. Lawrence, B. Fraass, and A. Lichter, Estimation of tumor control probability model parameters from 3-D dose distributions of non-small cell lung cancer patients., Lung Cancer 24, 31-37 (1999). 10.1016/S0169-5002(99)00019-7 (Pubitemid 29241815)
    • (1999) Lung Cancer , vol.24 , Issue.1 , pp. 31-37
    • Martel, M.K.1    Ten Haken, R.K.2    Hazuka, M.B.3    Kessler, M.L.4    Strawderman, M.5    Turrisi, A.T.6    Lawrence, T.S.7    Fraass, B.A.8    Lichter, A.S.9
  • 16
    • 0022323855 scopus 로고
    • Complication probability as assessed from dose volume histograms
    • 10.2307/3576626
    • J. Lyman, Complication probability as assessed from dose volume histograms., Radiat. Res. 104, S13-S19 (1985). 10.2307/3576626
    • (1985) Radiat. Res. , vol.104
    • Lyman, J.1
  • 17
    • 0026093854 scopus 로고
    • Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations
    • 10.1016/0360-3016(91)90173-2
    • G. J. Kutcher, C. Burman, L. Brewster, M. Goitein, and R. Mohan, Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations., Int. J. Radiat. Oncol. Biol. Phys. 21, 137-146 (1991). 10.1016/0360-3016(91)90173-2
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 137-146
    • Kutcher, G.J.1    Burman, C.2    Brewster, L.3    Goitein, M.4    Mohan, R.5
  • 18
    • 84858706009 scopus 로고    scopus 로고
    • Normal tissue complication probability estimation by the Lyman-Kutcher-Burman method does not accurately predict spinal cord tolerance to stereotactic radiosurgery
    • 10.1016/j.ijrob2011.03.004
    • M. E. Daly, G. Luxton, C. Y. H. Choi, I. C. Gibbs, S. D. Chang, J. R. Adler, and S. G. Soltys, Normal tissue complication probability estimation by the Lyman-Kutcher-Burman method does not accurately predict spinal cord tolerance to stereotactic radiosurgery., Int. J. Radiat. Oncol. Biol. Phys. 82, 2025-2032 (2012). 10.1016/j.ijrobp.2011.03.004
    • (2012) Int. J. Radiat. Oncol. Biol. Phys. , vol.82 , pp. 2025-2032
    • Daly, M.E.1    Luxton, G.2    Choi, C.Y.H.3    Gibbs, I.C.4    Chang, S.D.5    Adler, J.R.6    Soltys, S.G.7
  • 20
    • 38849205524 scopus 로고    scopus 로고
    • Universal survival curve and single fraction equivalent dose
    • 10.1016/j.ijrob2007.10.059
    • C. Park, L. Papiez, S. Zhang, M. Story, and R. Timmerman, Universal survival curve and single fraction equivalent dose., Int. J. Radiat. Oncol. Biol. Phys. 70, 847-852 (2008). 10.1016/j.ijrobp.2007.10.059
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.70 , pp. 847-852
    • Park, C.1    Papiez, L.2    Zhang, S.3    Story, M.4    Timmerman, R.5
  • 21
    • 77954301995 scopus 로고    scopus 로고
    • Clinical implications of adopting Monte Carlo treatment planning for CyberKnife
    • S. C. Sharma, J. T. Ott, J. B. Williams, and D. Dickow, Clinical implications of adopting Monte Carlo treatment planning for CyberKnife., J. Appl. Clin. Med. Phys. 11, 170-175 (2010).
    • (2010) J. Appl. Clin. Med. Phys. , vol.11 , pp. 170-175
    • Sharma, S.C.1    Ott, J.T.2    Williams, J.B.3    Dickow, D.4
  • 22
    • 34147110251 scopus 로고    scopus 로고
    • The impact of breathing motion versus heterogeneity effects in lung cancer treatment planning
    • DOI 10.1118/1.2713427
    • M. Rosu, I. Chetty, D. Tatro, and R. Ten Haken, The impact of breathing motion versus heterogeneity effects in lung cancer treatment planning., Med. Phys. 34, 1462-1473 (2007). 10.1118/1.2713427 (Pubitemid 46555776)
    • (2007) Medical Physics , vol.34 , Issue.4 , pp. 1462-1473
    • Rosu, M.1    Chetty, I.J.2    Tatro, D.S.3    Ten Haken, R.K.4
  • 23
    • 70350660836 scopus 로고    scopus 로고
    • A radiobiological analysis of the effect of 3D versus 4D image-based planning in lung cancer radiotherapy
    • 10.1088/0031-9155/54/18/011
    • T. Roland, P. Mavroidis, A. Gutierrez, V. Goytia, and N. Papanikolaou, A radiobiological analysis of the effect of 3D versus 4D image-based planning in lung cancer radiotherapy., Phys. Med. Biol. 54, 5509-5523 (2009). 10.1088/0031-9155/54/18/011
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5509-5523
    • Roland, T.1    Mavroidis, P.2    Gutierrez, A.3    Goytia, V.4    Papanikolaou, N.5
  • 24
    • 29144442021 scopus 로고    scopus 로고
    • Effects of averaging over motion and the resulting systematic errors in radiation therapy
    • DOI 10.1088/0031-9155/51/1/N01, PII S0031915506078638
    • P. M. Evans, C. Coolens, and E. Nioutsikou, Effects of averaging over motion and the resulting systematic errors in radiation therapy., Phys. Med. Biol. 51, N1-N7 (2006). 10.1088/0031-9155/51/1/N01 (Pubitemid 41803479)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.1
    • Evans, P.M.1    Coolens, C.2    Nioutsikou, E.3
  • 25
    • 80155134688 scopus 로고    scopus 로고
    • Dosimetric consequences of inter-fraction breathing-pattern variation on radiotherapy with personalized motion-assessed margins
    • 10.1088/0031-9155/56/22/003
    • A. Kavanagh, D. McQuaid, P. Evans, S. Webb, and M. Guckenberger, Dosimetric consequences of inter-fraction breathing-pattern variation on radiotherapy with personalized motion-assessed margins., Phys. Med. Biol. 56, 7033-7043 (2011). 10.1088/0031-9155/56/22/003
    • (2011) Phys. Med. Biol. , vol.56 , pp. 7033-7043
    • Kavanagh, A.1    McQuaid, D.2    Evans, P.3    Webb, S.4    Guckenberger, M.5
  • 26
    • 67649631512 scopus 로고    scopus 로고
    • Incorporating uncertainties in respiratory motion into 4D treatment plan optimization
    • 10.1118/1.3148582
    • E. Heath, J. Unkelback, and U. Oelfke, Incorporating uncertainties in respiratory motion into 4D treatment plan optimization., Med. Phys. 36, 3059-3071 (2009). 10.1118/1.3148582
    • (2009) Med. Phys. , vol.36 , pp. 3059-3071
    • Heath, E.1    Unkelback, J.2    Oelfke, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.