메뉴 건너뛰기




Volumn 101, Issue 9, 2012, Pages 773-775

Retrograde, transsubclavian implantation of a SAPIEN XT™ aortic valve prosthesis with the Edwards NovaFlex+™ system

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA STENOSIS; AORTA VALVE PROSTHESIS; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; ECHOCARDIOGRAPHY; HUMAN; LETTER; MALE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 84866070172     PISSN: 18610684     EISSN: 18610692     Source Type: Journal    
DOI: 10.1007/s00392-012-0460-2     Document Type: Letter
Times cited : (3)

References (8)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • 20961243 10.1056/NEJMoa1008232 1:CAS:528:DC%2BC3cXhtlCqurbP
    • Leon MB, Smith CR, Mack M et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363(17):1597-1607
    • (2010) N Engl J Med , vol.363 , Issue.17 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 2
    • 79961022681 scopus 로고    scopus 로고
    • One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: The European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • 21747054 10.1161/CIRCULATIONAHA.110.001545
    • Thomas M, Schymik G, Walther T et al (2011) One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 124(4):425-433
    • (2011) Circulation , vol.124 , Issue.4 , pp. 425-433
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 3
    • 79954444750 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Evidence on safety and efficacy compared with medical therapy. A systematic review of current literature
    • 21165626 10.1007/s00392-010-0268-x 1:STN:280:DC%2BC3M3ovFCitg%3D%3D
    • Figulla L, Neumann A, Figulla HR et al (2011) Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol 100(4):265-276
    • (2011) Clin Res Cardiol , vol.100 , Issue.4 , pp. 265-276
    • Figulla, L.1    Neumann, A.2    Figulla, H.R.3
  • 4
    • 84863718941 scopus 로고    scopus 로고
    • The risk-to-benefit ratio of transcatheter aortic valve implantation in specific patient cohorts: A single-centre experience
    • [Epub ahead of print]
    • Puls M, Viel T, Danner BC, et al (2012) The risk-to-benefit ratio of transcatheter aortic valve implantation in specific patient cohorts: a single-centre experience. Clin Res Cardiol [Epub ahead of print]
    • (2012) Clin Res Cardiol
    • Puls, M.1    Viel, T.2    Danner, B.C.3
  • 5
    • 79960905948 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation transapical: Step by step
    • 21807300 10.1053/j.semtcvs.2011.05.006
    • Walther T, Mollmann H, van Linden A et al (2011) Transcatheter aortic valve implantation transapical: step by step. Semin Thorac Cardiovasc Surg 23(1):55-61
    • (2011) Semin Thorac Cardiovasc Surg , vol.23 , Issue.1 , pp. 55-61
    • Walther, T.1    Mollmann, H.2    Van Linden, A.3
  • 6
    • 78751585130 scopus 로고    scopus 로고
    • Transcutaneous aortic valve implantation using the axillary/subclavian access: Feasibility and early clinical outcomes
    • 20434180 10.1016/j.jtcvs.2010.01.044 91 e1
    • Modine T, Obadia JF, Choukroun E et al (2011) Transcutaneous aortic valve implantation using the axillary/subclavian access: feasibility and early clinical outcomes. J Thorac Cardiovasc Surg 141(2):487-491 (91 e1)
    • (2011) J Thorac Cardiovasc Surg , vol.141 , Issue.2 , pp. 487-491
    • Modine, T.1    Obadia, J.F.2    Choukroun, E.3
  • 7
    • 78449261311 scopus 로고    scopus 로고
    • Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system
    • 20606135 10.1161/CIRCINTERVENTIONS.109.930453
    • Petronio AS, De Carlo M, Bedogni F et al (2010) Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system. Circ Cardiovasc Interv 3(4):359-366
    • (2010) Circ Cardiovasc Interv , vol.3 , Issue.4 , pp. 359-366
    • Petronio, A.S.1    De Carlo, M.2    Bedogni, F.3
  • 8
    • 77950548376 scopus 로고    scopus 로고
    • First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis
    • 20088013
    • Sharp AS, Michev I, Colombo A (2010) First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis. Catheter Cardiovasc Interv 75(4):507-510
    • (2010) Catheter Cardiovasc Interv , vol.75 , Issue.4 , pp. 507-510
    • Sharp, A.S.1    Michev, I.2    Colombo, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.