Ventilation distribution in rats: Part 2 - A comparison of electrical impedance tomography and hyperpolarised helium magnetic resonance imaging

Author keywords

Electrical impedance tomography; Functional lung imaging; Hyperpolarized helium magnetic resonance lmaging; Ventilation distribution

Indexed keywords

AIR DISTRIBUTION; AIR SPACE; ELECTRICAL IMPEDANCE TOMOGRAPHY; GEOMETRIC CENTRE; GOLD STANDARDS; HELIUM ISOTOPES; HOMOGENEITY INDEX; HYPERPOLARIZED; IN-VIVO; LOWER RESOLUTION; LUNG IMAGING; LUNG IMPEDANCE; LUNG VENTILATION; MRI SCANNERS;

EID: 84865958781     PISSN: None     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-11-68     Document Type: Article
Times cited : (14)

References (17)
  • 3
    • 0033822157 scopus 로고    scopus 로고
    • Probing lung physiology with xenon polarization transfer contrast (XTC)
    • 10.1002/1522-2594(200009)44:3<349::AID-MRM2>3.0.CO;2-J, 10975884
    • Ruppert K, Brookeman JR, Hagspiel KD, Mugler JP. Probing lung physiology with xenon polarization transfer contrast (XTC). Magn Reson Med 2000, 44:349-357. 10.1002/1522-2594(200009)44:3<349::AID-MRM2>3.0.CO;2-J, 10975884.
    • (2000) Magn Reson Med , vol.44 , pp. 349-357
    • Ruppert, K.1    Brookeman, J.R.2    Hagspiel, K.D.3    Mugler, J.P.4
  • 4
    • 0022341248 scopus 로고
    • Convection- and diffusion-dependent ventilation maldistribution in normal subjects
    • Crawford AB, Makowska M, Paiva M, Engel LA. Convection- and diffusion-dependent ventilation maldistribution in normal subjects. J Appl Physiol 1985, 59:838-846.
    • (1985) J Appl Physiol , vol.59 , pp. 838-846
    • Crawford, A.B.1    Makowska, M.2    Paiva, M.3    Engel, L.A.4
  • 5
    • 0016599188 scopus 로고
    • Effect of gas density on dynamic pulmonary compliance
    • Forkert L, Wood LD, Cherniack RM. Effect of gas density on dynamic pulmonary compliance. J Appl Physiol 1975, 39:906-910.
    • (1975) J Appl Physiol , vol.39 , pp. 906-910
    • Forkert, L.1    Wood, L.D.2    Cherniack, R.M.3
  • 6
    • 84865640354 scopus 로고    scopus 로고
    • Ventilation distribution in rats: Part I - The effect of gas composition as measured with electrical impedance tomography
    • 10.1186/1475-925X-11-64, 22947026
    • Dunster KR, Friese M, Fraser JF, Cowin GJ, Schibler A. Ventilation distribution in rats: Part I - The effect of gas composition as measured with electrical impedance tomography. BioMedical Engineering OnLine 2012, 11:64. 10.1186/1475-925X-11-64, 22947026.
    • (2012) BioMedical Engineering OnLine , vol.11 , pp. 64
    • Dunster, K.R.1    Friese, M.2    Fraser, J.F.3    Cowin, G.J.4    Schibler, A.5
  • 7
    • 62249200419 scopus 로고    scopus 로고
    • Principles of electrical impedance tomography and its clinical application
    • 10.1097/CCM.0b013e3181958d2f, 19114889
    • Bodenstein M, David M, Markstaller K. Principles of electrical impedance tomography and its clinical application. Crit Care Med 2009, 37:713-724. 10.1097/CCM.0b013e3181958d2f, 19114889.
    • (2009) Crit Care Med , vol.37 , pp. 713-724
    • Bodenstein, M.1    David, M.2    Markstaller, K.3
  • 8
    • 70350446641 scopus 로고    scopus 로고
    • Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography
    • 10.1088/0967-3334/30/10/008, 19738318
    • Rooney D, Friese M, Fraser JF KRD, Schibler A. Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography. Physiol Meas 2009, 30:1075-1085. 10.1088/0967-3334/30/10/008, 19738318.
    • (2009) Physiol Meas , vol.30 , pp. 1075-1085
    • Rooney, D.1    Friese, M.2    Fraser JF, K.R.D.3    Schibler, A.4
  • 9
    • 0033870372 scopus 로고    scopus 로고
    • MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging
    • 10.1016/S0730-725X(00)00154-5, 10930785
    • Hedlund LW, Cofer GP, Owen SJ, Allan Johnson G. MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging. Magn Reson Imaging 2000, 18:753-759. 10.1016/S0730-725X(00)00154-5, 10930785.
    • (2000) Magn Reson Imaging , vol.18 , pp. 753-759
    • Hedlund, L.W.1    Cofer, G.P.2    Owen, S.J.3    Allan Johnson, G.4
  • 11
    • 84855271946 scopus 로고    scopus 로고
    • Bethesda, Maryland, USA, National Institutes of Health
    • Rasband W. ImageJ 2009, , Bethesda, Maryland, USA, National Institutes of Health, http://rsbinfonihgov/ij/.
    • (2009) ImageJ
    • Rasband, W.1
  • 12
    • 33749446717 scopus 로고    scopus 로고
    • Lung volume recruitment after surfactant administration modifies spatial distribution of ventilation
    • 10.1164/rccm.200512-1942OC, 16840739
    • Frerichs I, Dargaville PA, van Genderingen H, Morel DR, Rimensberger PC. Lung volume recruitment after surfactant administration modifies spatial distribution of ventilation. Am J Respir Crit Care Med 2006, 174:772-779. 10.1164/rccm.200512-1942OC, 16840739.
    • (2006) Am J Respir Crit Care Med , vol.174 , pp. 772-779
    • Frerichs, I.1    Dargaville, P.A.2    van Genderingen, H.3    Morel, D.R.4    Rimensberger, P.C.5
  • 13
    • 73949116537 scopus 로고    scopus 로고
    • Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution
    • 10.1007/s00134-009-1589-y, 19652949
    • Zhao Z, Moller K, Steinmann D, Frerichs I, Guttmann J. Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution. Intensive Care Med 2009, 35:1900-1906. 10.1007/s00134-009-1589-y, 19652949.
    • (2009) Intensive Care Med , vol.35 , pp. 1900-1906
    • Zhao, Z.1    Moller, K.2    Steinmann, D.3    Frerichs, I.4    Guttmann, J.5
  • 14
    • 0348052290 scopus 로고    scopus 로고
    • EIT System for clinical and space applications
    • Vienna, Austria, Dec 04-08, 2002 IFMBE Proceedings Series
    • Hahn G, Dudykevych T, Frerichs I, Hellige G. EIT System for clinical and space applications. Proc 2nd Eur Med Biol Eng Conf 2002, 3:110-111. Vienna, Austria, Dec 04-08, 2002 IFMBE Proceedings Series.
    • (2002) Proc 2nd Eur Med Biol Eng Conf , vol.3 , pp. 110-111
    • Hahn, G.1    Dudykevych, T.2    Frerichs, I.3    Hellige, G.4
  • 15
    • 0033997566 scopus 로고    scopus 로고
    • Two-dimensional finite element modelling of the neonatal head
    • 10.1088/0967-3334/21/1/306, 10719998
    • Gibson A, Bayford R, Holder D. Two-dimensional finite element modelling of the neonatal head. Physiol Meas 2000, 21:45-52. 10.1088/0967-3334/21/1/306, 10719998.
    • (2000) Physiol Meas , vol.21 , pp. 45-52
    • Gibson, A.1    Bayford, R.2    Holder, D.3
  • 16
    • 0030657934 scopus 로고    scopus 로고
    • Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    • Adler A, Amyot R, Guardo R, Bates JH, Berthiaume Y. Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 1997, 83:1762-1767.
    • (1997) J Appl Physiol , vol.83 , pp. 1762-1767
    • Adler, A.1    Amyot, R.2    Guardo, R.3    Bates, J.H.4    Berthiaume, Y.5
  • 17
    • 41649114496 scopus 로고    scopus 로고
    • Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury
    • 10.1097/CCM.0B013E3181652EDD, 18431279
    • Wrigge H, Zinserling J, Muders T, Varelmann D, Gunther U, von der Groeben C, Magnusson A, Hedenstierna G, Putensen C. Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury. Crit Care Med 2008, 36:903-909. 10.1097/CCM.0B013E3181652EDD, 18431279.
    • (2008) Crit Care Med , vol.36 , pp. 903-909
    • Wrigge, H.1    Zinserling, J.2    Muders, T.3    Varelmann, D.4    Gunther, U.5    von der Groeben, C.6    Magnusson, A.7    Hedenstierna, G.8    Putensen, C.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.