메뉴 건너뛰기




Volumn 223, Issue , 2012, Pages 80-84

Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans

Author keywords

Background correction; EPR; Orthogonality in quadrature detector; Rapid scan

Indexed keywords

BACKGROUND CORRECTION; BACKGROUND OSCILLATIONS; BACKGROUND SIGNALS; EPR SIGNALS; FREQUENCY DOMAINS; HALF CYCLE; NON-ORTHOGONALITY; OFF-RESONANCE; QUADRATURE CHANNEL; QUADRATURE DETECTORS; RAPID SCAN; SCAN DIRECTION; SIGNAL CHANNELS; SIGNAL TO NOISE;

EID: 84865808761     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2012.07.023     Document Type: Article
Times cited : (33)

References (11)
  • 1
    • 80052933636 scopus 로고    scopus 로고
    • Comparison of continuous wave, spin echo, and rapid scan EPR of irradiated fused quartz
    • D.G. Mitchell, R.W. Quine, M. Tseitlin, V. Meyer, S.S. Eaton, and G.R. Eaton Comparison of continuous wave, spin echo, and rapid scan EPR of irradiated fused quartz Radiat. Meas. 46 2011 993 996
    • (2011) Radiat. Meas. , vol.46 , pp. 993-996
    • Mitchell, D.G.1    Quine, R.W.2    Tseitlin, M.3    Meyer, V.4    Eaton, S.S.5    Eaton, G.R.6
  • 3
    • 19944405163 scopus 로고    scopus 로고
    • Rapid-scan EPR with triangular scans and Fourier deconvolution to recover the slow-scan spectrum
    • J.P. Joshi, J.R. Ballard, G.A. Rinard, R.W. Quine, S.S. Eaton, and G.R. Eaton Rapid-scan EPR with triangular scans and Fourier deconvolution to recover the slow-scan spectrum J. Magn. Reson. 175 2005 44 51
    • (2005) J. Magn. Reson. , vol.175 , pp. 44-51
    • Joshi, J.P.1    Ballard, J.R.2    Rinard, G.A.3    Quine, R.W.4    Eaton, S.S.5    Eaton, G.R.6
  • 5
    • 77949487175 scopus 로고    scopus 로고
    • Combining absorption and dispersion signals to improve signal-to-noise for rapid scan EPR imaging
    • M. Tseitlin, R.W. Quine, G.A. Rinard, S.S. Eaton, and G.R. Eaton Combining absorption and dispersion signals to improve signal-to-noise for rapid scan EPR imaging J. Magn. Reson. 203 2010 305 310
    • (2010) J. Magn. Reson. , vol.203 , pp. 305-310
    • Tseitlin, M.1    Quine, R.W.2    Rinard, G.A.3    Eaton, S.S.4    Eaton, G.R.5
  • 6
    • 0033444923 scopus 로고    scopus 로고
    • 1-D EPR imaging of conducting and lossy-dielectric samples
    • L.K. Aminov, M.P. Tseitlin, and K.M. Salikhov 1-D EPR imaging of conducting and lossy-dielectric samples Appl. Magn. Reson. 16 1999 341 362
    • (1999) Appl. Magn. Reson. , vol.16 , pp. 341-362
    • Aminov, L.K.1    Tseitlin, M.P.2    Salikhov, K.M.3
  • 9
    • 18644375009 scopus 로고    scopus 로고
    • A pulsed and continuous wave 250 MHz electron paramagnetic resonance spectrometer
    • R.W. Quine, G.A. Rinard, S.S. Eaton, and G.R. Eaton A pulsed and continuous wave 250 MHz electron paramagnetic resonance spectrometer Magn. Reson. Eng. 15 2002 59 91
    • (2002) Magn. Reson. Eng. , vol.15 , pp. 59-91
    • Quine, R.W.1    Rinard, G.A.2    Eaton, S.S.3    Eaton, G.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.