메뉴 건너뛰기




Volumn , Issue , 2009, Pages 31-41

The Origins of UHMWPE in Total Hip Arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84865753844     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-0-12-374721-1.00004-3     Document Type: Chapter
Times cited : (15)

References (21)
  • 1
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra- high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, Edidin AA Advances in the processing, sterilization, and crosslinking of ultra- high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999, 20:1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 3
    • 0001486818 scopus 로고
    • Long term clinical results of THR. Clinical results of THR of an alumina head with a cross-linked UHMWPE cup
    • Oonishi H Long term clinical results of THR. Clinical results of THR of an alumina head with a cross-linked UHMWPE cup. Orthop Surg Traumatol 1995, 38:1255-1264.
    • (1995) Orthop Surg Traumatol , vol.38 , pp. 1255-1264
    • Oonishi, H.1
  • 4
    • 0018186475 scopus 로고
    • The radiation improvement of polyethylene prostheses: A preliminary study
    • Grobbelaar CJ, Du Plessis TA, Marais F The radiation improvement of polyethylene prostheses: A preliminary study. J Bone Joint Surg 1978, 60-B:370-374.
    • (1978) J Bone Joint Surg , pp. 370-374
    • Grobbelaar, C.J.1    Du Plessis, T.A.2    Marais, F.3
  • 5
    • 0021061474 scopus 로고
    • Silane cross-linked polyethylene for prosthetic applications. Certain physical and mechanical properties related to the nature of the material
    • Atkinson JR, Cicek RZ Silane cross-linked polyethylene for prosthetic applications. Certain physical and mechanical properties related to the nature of the material. Biomaterials 1983, 4:267-275.
    • (1983) Biomaterials , vol.4 , pp. 267-275
    • Atkinson, J.R.1    Cicek, R.Z.2
  • 6
    • 0021747182 scopus 로고
    • Silane crosslinked polyethylene for prosthetic applications. Part II. Creep and wear behavior and a preliminary moulding test
    • Atkinson JR, Cicek RZ Silane crosslinked polyethylene for prosthetic applications. Part II. Creep and wear behavior and a preliminary moulding test. Biomaterials 1984, 5:326-335.
    • (1984) Biomaterials , vol.5 , pp. 326-335
    • Atkinson, J.R.1    Cicek, R.Z.2
  • 7
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone & Joint Surg 1996, 78B:280-285.
    • (1996) J Bone & Joint Surg , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 9
    • 0028129938 scopus 로고
    • Ultra-high molecular weight polyethylene. The material and its use in total joint implants
    • Li S, Burstein AH Ultra-high molecular weight polyethylene. The material and its use in total joint implants. J Bone Joint Surg Am 1994, 76:1080-1090.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1080-1090
    • Li, S.1    Burstein, A.H.2
  • 10
    • 50549156477 scopus 로고
    • Arthroplasty of the hip: a new operation
    • Charnley J Arthroplasty of the hip: a new operation. Lancet 1961, I:1129-1132.
    • (1961) Lancet , vol.I , pp. 1129-1132
    • Charnley, J.1
  • 12
    • 84882480980 scopus 로고
    • The growth of an idea: 1951-1961
    • Springer-Verlag, London
    • Waugh W The growth of an idea: 1951-1961. John Charnley: the man and the hip 1990, Springer-Verlag, London.
    • (1990) John Charnley: the man and the hip
    • Waugh, W.1
  • 13
  • 16
    • 0014457406 scopus 로고
    • The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip
    • Charnley J, Kamangar A, Longfield MD The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng 1969, 7:31-39.
    • (1969) Med Biol Eng , vol.7 , pp. 31-39
    • Charnley, J.1    Kamangar, A.2    Longfield, M.D.3
  • 17
    • 84882533902 scopus 로고
    • The Charnley-Thackray Relationship 1947-1982
    • Springer-Verlag, London
    • Waugh W The Charnley-Thackray Relationship 1947-1982. John Charnley: the man and the hip 1990, Springer-Verlag, London.
    • (1990) John Charnley: the man and the hip
    • Waugh, W.1
  • 18
    • 84882505662 scopus 로고    scopus 로고
    • Personal Communication. July, 2002.
    • Craven H. Personal Communication. July, 2002.
    • Craven, H.1
  • 19
    • 0001990344 scopus 로고
    • Tissue reaction to the polytetrafluoroethylene
    • Charnley J Tissue reaction to the polytetrafluoroethylene. Lancet 1963, II:1379.
    • (1963) Lancet , vol.II , pp. 1379
    • Charnley, J.1
  • 20
  • 21
    • 0030331025 scopus 로고    scopus 로고
    • An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation?
    • Isaac GH, Dowson D, Wroblewski BM An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation?. Proc Inst Mech Eng [H] 1996, 210:209-216.
    • (1996) Proc Inst Mech Eng [H] , vol.210 , pp. 209-216
    • Isaac, G.H.1    Dowson, D.2    Wroblewski, B.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.