The effects of locked and unlocked neutralization plates on load bearing of fractures fixed with a lag screw

Author keywords

lag screw fixation; locked plates; plate neutralization

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; CLINICAL EFFECTIVENESS; FEMUR FRACTURE; HUMAN; LOCKED PLATE; PLATE FIXATION; PRIORITY JOURNAL; UNLOCKED PLATE; WEIGHT;

EID: 84865750360     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e31823b3dd1     Document Type: Article
Times cited : (8)

References (9)
  • 5
    • 10644249303 scopus 로고    scopus 로고
    • Functional load of plates in fracture fixation in vivo and its correlate in bone healing
    • Stoffel K, Klaue K, Perren SM. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury. 2000;31(suppl 2): S-B37-S-B50.
    • (2000) Injury. , vol.31 , Issue.SUPPL. 2
    • Stoffel, K.1    Klaue, K.2    Perren, S.M.3
  • 6
    • 33845735111 scopus 로고    scopus 로고
    • Fixation of osteoporotic distal fibula fractures: A biomechanical comparison of locking versus conventional plates
    • Kim T, Ayturk UM, Haskell A, Fixation of osteoporotic distal fibula fractures: a biomechanical comparison of locking versus conventional plates. J Foot Ankle Surg. 2007;46:2-6.
    • (2007) J Foot Ankle Surg , vol.46 , pp. 2-6
    • Kim, T.1    Ayturk, U.M.2    Haskell, A.3
  • 7
    • 33748954850 scopus 로고    scopus 로고
    • Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: A biomechanical study
    • Minihane KP, Lee C, Ahn C, et al. Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study. J Orthop Trauma. 2006;20:562-566.
    • (2006) J Orthop Trauma , vol.20 , pp. 562-566
    • Minihane, K.P.1    Lee, C.2    Ahn, C.3
  • 8
    • 0042384780 scopus 로고    scopus 로고
    • Axial compression generated by cortical and cancellous lag screws inthe equine distal phalanx
    • Johnson KA, Smith FW. Axial compression generated by cortical and cancellous lag screws inthe equine distal phalanx.Ve t J. 2003;166:159-163.
    • (2003) Ve T J. , vol.166 , pp. 159-163
    • Johnson, K.A.1    Smith, F.W.2
  • 9
    • 0347704698 scopus 로고
    • Biomechanical studies on torque and force of the 4.5 mm ao cortex screw as a lag screw
    • Uhthoff HK, ed Berlin, Germany: SpringerVerlag
    • Gotzen L, Haas N, Hütter J. Biomechanical studies on torque and force of the 4.5 mm AO cortex screw as a lag screw. In: Uhthoff HK, ed. Current Concepts of Internal Fixation of Fractures. Berlin, Germany: SpringerVerlag; 1980:259-267.
    • (1980) Current Concepts of Internal Fixation of Fractures , pp. 259-267
    • Gotzen, L.1    Haas, N.2    Hütter, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.