메뉴 건너뛰기




Volumn 18, Issue 5, 2012, Pages 1540-1546

Superluminescent diode-based multiple-gas sensor for NH 3 and H 2O vapor monitoring

Author keywords

Absorption spectroscopy; ammonia (NH 3); Fabry Perot Etalon; gas sensing; superluminescent diode (SLED); water vapor (H 2O vapor)

Indexed keywords

COMBINATION BANDS; DETECTION LIMITS; EMISSION MONITORING; EMISSION WAVELENGTH; FABRY-PEROT ETALONS; FREE SPECTRAL RANGE; GAS SENSING; INTERFERENCE EFFECTS; INTERFERING SPECIES; MULTIPLE-GAS SENSOR; SUPERLUMINESCENT DIODE; SUPERLUMINESCENT LIGHT EMITTING DIODES; TEMPERATURE RANGE; TRACE-GASES;

EID: 84865697812     PISSN: 1077260X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSTQE.2011.2179021     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 9644287874 scopus 로고    scopus 로고
    • Ammoniamonitoring at trace level using photoacoustic spectroscopy in industrial and environmental applications
    • S. Schilt, L. Thevenaz, M. Nikles, L. Emmenegger, and C. Huglin, "Ammoniamonitoring at trace level using photoacoustic spectroscopy in industrial and environmental applications," Spectrochim. Acta - Part A, vol. 60, no. 14, pp. 3259-3268, 2004.
    • (2004) Spectrochim. Acta-Part A , vol.60 , Issue.14 , pp. 3259-3268
    • Schilt, S.1    Thevenaz, L.2    Nikles, M.3    Emmenegger, L.4    Huglin, C.5
  • 2
    • 79959529617 scopus 로고    scopus 로고
    • Breath ammonia detection based on tunable fiber laser photoacoustic spectroscopy
    • J.Wang,W. Zhang, L. Li, and Q. Yu, "Breath ammonia detection based on tunable fiber laser photoacoustic spectroscopy," Appl. Phys. B, vol. 103, pp. 263-269, 2011.
    • (2011) Appl. Phys. B , vol.103 , pp. 263-269
    • J.WangW. Zhang1    Li, L.2    Yu, Q.3
  • 3
    • 0038239098 scopus 로고
    • Laser spectroscopy for in-situ ammonia monitoring
    • H. Ahlberg, S. Lundqvist, R. Tell, and T. Andersson, "Laser spectroscopy for in-situ ammonia monitoring," Spectrosc. Eur., vol. 6, no. 2, pp. 22-26, 1994.
    • (1994) Spectrosc. Eur. , vol.6 , Issue.2 , pp. 22-26
    • Ahlberg, H.1    Lundqvist, S.2    Tell, R.3    Andersson, T.4
  • 4
    • 0037332493 scopus 로고    scopus 로고
    • Selective catalytic reduction of NO by ammonia with fly ash catalyst
    • X. Xuan, C. Yue, S. Li, and Q. Yao, "Selective catalytic reduction of NO by ammonia with fly ash catalyst," Fuel, vol. 82, no. 5, pp. 575-579, 2003.
    • (2003) Fuel , vol.82 , Issue.5 , pp. 575-579
    • Xuan, X.1    Yue, C.2    Li, S.3    Yao, Q.4
  • 5
    • 0041632344 scopus 로고    scopus 로고
    • Selective catalytic reduction of NOx with NH3 over zeolite H-ZSM-5: Influence of transient ammonia supply
    • M. Wallin, C. J. Karlsson, M. Skoglundh, and A. Palmqvis, "Selective catalytic reduction of NOx with NH3 over zeolite H-ZSM-5: Influence of transient ammonia supply," J. Catalysis, vol. 218, no. 2, pp. 354-364, 2003.
    • (2003) J. Catalysis , vol.218 , Issue.2 , pp. 354-364
    • Wallin, M.1    Karlsson, C.J.2    Skoglundh, M.3    Palmqvis, A.4
  • 7
    • 1542509581 scopus 로고    scopus 로고
    • High sensitivity in gas analysis with photoacoustic detection
    • J. Kauppinen, K.Wilcken, I. Kauppinen, and V. Koskinen, "High sensitivity in gas analysis with photoacoustic detection," Microchem. J., vol. 76, no. 1-2, pp. 151-159, 2004.
    • (2004) Microchem. J. , vol.76 , Issue.1-2 , pp. 151-159
    • Kauppinen, J.1    Wilcken, K.2    Kauppinen, I.3    Koskinen, V.4
  • 8
    • 46749158372 scopus 로고    scopus 로고
    • Fourier transform infrared measurement of solid, liquid, and gas-phase samples with a single photoacoustic cell
    • J. Uotila and J. Kauppinen, "Fourier transform infrared measurement of solid, liquid, and gas-phase samples with a single photoacoustic cell," Appl. Spectrosc., vol. 62, no. 6, pp. 655-660, 2008.
    • (2008) Appl. Spectrosc. , vol.62 , Issue.6 , pp. 655-660
    • Uotila, J.1    Kauppinen, J.2
  • 9
    • 10444256234 scopus 로고    scopus 로고
    • Ammonia detection by use of quartzenhanced photoacoustic spectroscopy with a near-IR telecommunication diode laser
    • A. A. Kosterev and F. K. Tittel, "Ammonia detection by use of quartzenhanced photoacoustic spectroscopy with a near-IR telecommunication diode laser," Appl. Opt., vol. 43, pp. 6213-6217, 2004.
    • (2004) Appl. Opt. , vol.43 , pp. 6213-6217
    • Kosterev, A.A.1    Tittel, F.K.2
  • 10
    • 33645516244 scopus 로고    scopus 로고
    • Development of multipoint vibrational coherent anti-Stokes Raman spectroscopy for flame applications
    • M. Afzelius, P. Bengtsson, J. Bood, C. Brackmann, and A. Kurtz, "Development of multipoint vibrational coherent anti-Stokes Raman spectroscopy for flame applications," Appl.Opt., vol. 45, no. 6, pp. 1177-1186, 2006.
    • (2006) Appl.Opt. , vol.45 , Issue.6 , pp. 1177-1186
    • Afzelius, M.1    Bengtsson, P.2    Bood, J.3    Brackmann, C.4    Kurtz, A.5
  • 11
    • 4043179804 scopus 로고    scopus 로고
    • 2 concentration measurements in the exhaust stream of a liquid-fueled combustor using dual-pump coherent anti-Stokes Raman scattering (CARS) spectroscopy
    • DOI 10.1016/j.combustflame.2004.04.012, PII S0010218004001178
    • S. Roy, T. R. Meyer, R. P. Lucht, V. M. Belovich, E. Corporan, and J. R. Gord, "Temperature and CO2 concentration measurements in the exhaust stream of a liquid-fueled combustor using dual-pump coherent anti-Stokes Raman scattering (CARS) spectroscopy," Combust. Flame, vol. 138, no. 3, pp. 273-284, 2004. (Pubitemid 39078270)
    • (2004) Combustion and Flame , vol.138 , Issue.3 , pp. 273-284
    • Roy, S.1    Meyer, T.R.2    Lucht, R.P.3    Belovich, V.M.4    Corporan, E.5    Gord, J.R.6
  • 12
    • 34547498722 scopus 로고    scopus 로고
    • Fourier-transform cavity-enhanced absorption spectroscopy using an incoherent broadband light source
    • DOI 10.1364/AO.46.003611
    • A. A. Ruth, J. Orphal, and S. E. Fiedler, "Fourier-transform cavityenhanced absorption spectroscopy using an incoherent broadband light source," Appl. Opt., vol. 46, no. 17, pp. 3611-3616, 2007. (Pubitemid 47184236)
    • (2007) Applied Optics , vol.46 , Issue.17 , pp. 3611-3616
    • Ruth, A.A.1    Orphal, J.2    Fiedler, S.E.3
  • 14
    • 0032022767 scopus 로고    scopus 로고
    • A diode-laser absorption sensor system for combustion emission measurements
    • PII S095702339886400X
    • R. M. Mihalcea, D. S. Baer, and R. K. Hanson, "A diode-laser absorption sensor system for combustion emission measurements," Meas. Sci. Technol., vol. 9, no. 3, pp. 327-338, 1998. (Pubitemid 128589167)
    • (1998) Measurement Science and Technology , vol.9 , Issue.3 , pp. 327-338
    • Mihalcea, R.M.1    Baer, D.S.2    Hanson, R.K.3
  • 16
    • 0034741095 scopus 로고    scopus 로고
    • Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN
    • D. Rehle, D. Leleux, M. Erdelyi, F. K. Tittel, M. P. Fraser, and S. Friedfeld, "Ambient formaldehyde detection with a laser spectrometer based on difference frequency generation in PPLN," Appl. Phys. B, vol. 72, pp. 947- 952, 2001. (Pubitemid 32910018)
    • (2001) Applied Physics B: Lasers and Optics , vol.72 , Issue.8 , pp. 947-952
    • Rehle, D.1    Leleux, D.2    Erdelyi, M.3    Tittel, F.4    Fraser, M.5    Friedfeld, S.6
  • 17
    • 70449670681 scopus 로고    scopus 로고
    • Development of a widely tunable mid-infrared coherent optical source based on a difference frequency generation in a periodically poled LiNbO3
    • N. J.Vasa,K. Funakoshi, and S.Yokoyama, "Development of a widely tunable mid-infrared coherent optical source based on a difference frequency generation in a periodically poled LiNbO3, " Eng. Sci. Rep. Kyushu Univ., vol. 26, no. 4, pp. 389-394, 2005.
    • (2005) Eng. Sci. Rep. Kyushu Univ. , vol.26 , Issue.4 , pp. 389-394
    • Vasa, N.J.1    Funakoshi, K.2    Yokoyama, S.3
  • 18
    • 77951943674 scopus 로고    scopus 로고
    • Detection of CH4 in the mid-IR using difference frequency generation with tunable diode laser spectroscopy
    • May
    • I. Armstrong,W. Johnstone, K. Duffin, M. Lengden, A. Chakraborty, and K. Ruxton, "Detection of CH4 in the mid-IR using difference frequency generation with tunable diode laser spectroscopy," IEEE J. Lightw. Technol., vol. 28, no. 10, pp. 1435-1442, May 2010.
    • (2010) IEEE J. Lightw. Technol. , vol.28 , Issue.10 , pp. 1435-1442
    • Armstrong, I.1    Johnstone, W.2    Duffin, K.3    Lengden, M.4    Chakraborty, A.5    Ruxton, K.6
  • 19
    • 0037100975 scopus 로고    scopus 로고
    • 2 transitions near 4.25 μm
    • D. Mazzotti, S. Borri, P. Cancio, G. Giusfredi, and P. D. Natale, "Low-power lamb-dip spectroscopy of very weak CO2 transitions near 4.25 μm," Opt. Lett., vol. 27, no. 14, pp. 1256-1258, 2002. (Pubitemid 34878672)
    • (2002) Optics Letters , vol.27 , Issue.14 , pp. 1256-1258
    • Mazzotti, D.1    Borri, S.2    Cancio, P.3    Giusfredi, G.4    De Natale, P.5
  • 20
    • 66949164119 scopus 로고    scopus 로고
    • External cavity widely tunable quantum cascade laser based hollowwaveguide gas sensors formultianalyte detection
    • C. Young, S. S. Kim, Y. Luzinova, M.Weida, D. Arnone, E. Takeuchi, T. Day, and B. Mizaikoff, "External cavity widely tunable quantum cascade laser based hollowwaveguide gas sensors formultianalyte detection," Sens. Actuat. B: Chem., vol. 140, no. 1, pp. 24-28, 2009.
    • (2009) Sens. Actuat. B: Chem. , vol.140 , Issue.1 , pp. 24-28
    • Young, C.1    Kim, S.S.2    Luzinova, Y.3    Weida, M.4    Arnone, D.5    Takeuchi, E.6    Day, T.7    Mizaikoff, B.8
  • 22
    • 85028123960 scopus 로고    scopus 로고
    • NO trace gas sensor based on quartz enhanced photoacoustic spectroscopy and external cavity quantum cascade laser
    • V. Spagnolo, A. A. Kosterev, L. Dong, R. Lewicki, and F. K. Tittel, "NO trace gas sensor based on quartz enhanced photoacoustic spectroscopy and external cavity quantum cascade laser," Appl. Phys. B., vol. 100, pp. 125-130, 2010.
    • (2010) Appl. Phys. B. , vol.100 , pp. 125-130
    • Spagnolo, V.1    Kosterev, A.A.2    Dong, L.3    Lewicki, R.4    Tittel, F.K.5
  • 23
    • 70449625737 scopus 로고    scopus 로고
    • Gas sensors based on superluminescent diodes for combustion monitoring
    • N. J. Vasa andM. Singaperumal, "Gas sensors based on superluminescent diodes for combustion monitoring," Appl. Opt., vol. 48, no. 31, pp. G1- G5, 2009.
    • (2009) Appl. Opt. , vol.48 , Issue.31
    • Vasa, N.J.1    Singaperumal, M.2
  • 24
    • 0027694673 scopus 로고
    • Analysis of the high-resolution spectrum of ammonia (14NH3) in the near-infrared region, 6400-6900 cm1
    • L. Lundsbergnielsen, F. Hegelund, and F. M. Nicolaisen, "Analysis of the high-resolution spectrum of ammonia (14NH3) in the near-infrared region, 6400-6900 cm1, " J. Mol. Spectrosc., vol. 162, no. 1, pp. 230-245, 1993.
    • (1993) J. Mol. Spectrosc. , vol.162 , Issue.1 , pp. 230-245
    • Lundsbergnielsen, L.1    Hegelund, F.2    Nicolaisen, F.M.3