메뉴 건너뛰기




Volumn 47, Issue 7, 2012, Pages 541-547

Preliminary insight into dose deposition processes in sedimentary media on a scale of single grains: Monte Carlo modelling of the effect of water on the gamma dose rate

Author keywords

Gamma dose rate; GEANT4; Moisture effect; Monte Carlo simulations

Indexed keywords

COMPREHENSIVE ANALYSIS; CROSS SECTION; DOSE DEPOSITION; DOSE RATE; EFFECT OF WATER; GAMMA DOSE RATE; GEANT4; GEANT4 CODE; GEANT4 TOOLKITS; GEOMETRY EFFECTS; GRAIN SIZE; INTERACTION MODES; MASS STOPPING POWER; MOISTURE EFFECTS; MONTE CARLO MODELLING; MONTE CARLO SIMULATION; MONTE CARLO TRANSPORT CODE; MORPHOLOGICAL FEATURES; PHOTON INTERACTIONS; RETROSPECTIVE DOSIMETRY; SECONDARY ELECTRONS; SEDIMENT GRAINS; SINGLE GRAINS;

EID: 84865677733     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2012.05.004     Document Type: Article
Times cited : (37)

References (28)
  • 2
    • 33745807559 scopus 로고
    • Moisture correction for annual gamma dose
    • M.J. Aitken, and J. Xie Moisture correction for annual gamma dose Ancient TL 8 2 1990 6 9
    • (1990) Ancient TL , vol.8 , Issue.2 , pp. 6-9
    • Aitken, M.J.1    Xie, J.2
  • 4
    • 33645696556 scopus 로고    scopus 로고
    • Geant4 developments and applications
    • Geant4 Collaboration
    • J. Allison Geant4 Collaboration Geant4 developments and applications IEEE Transactions on Nuclear Sciences 53 2006 270 278
    • (2006) IEEE Transactions on Nuclear Sciences , vol.53 , pp. 270-278
    • Allison, J.1
  • 8
    • 45249123444 scopus 로고    scopus 로고
    • Development of reference database for gamma dose assessment in retrospective luminescence dosimetry
    • I.K. Bailiff, and H.A. Slim Development of reference database for gamma dose assessment in retrospective luminescence dosimetry Radiation Measurements 43 2008 859 863
    • (2008) Radiation Measurements , vol.43 , pp. 859-863
    • Bailiff, I.K.1    Slim, H.A.2
  • 18
    • 70449122800 scopus 로고    scopus 로고
    • Accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for simulation of electron scatter in external beam radiotherapy
    • B.A. Faddegon, I. Kawrakow, Y. Kubyshin, J. Perl, J. Sempau, and L. Urban Accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for simulation of electron scatter in external beam radiotherapy Physics in Medicine and Biology 54 2009 6151 6163
    • (2009) Physics in Medicine and Biology , vol.54 , pp. 6151-6163
    • Faddegon, B.A.1    Kawrakow, I.2    Kubyshin, Y.3    Perl, J.4    Sempau, J.5    Urban, L.6
  • 20
    • 79151471920 scopus 로고    scopus 로고
    • Determining gamma dose rates by field gamma spectroscopy in sedimentary media: Results of Monte Carlo simulations
    • G. Guérin, and N. Mercier Determining gamma dose rates by field gamma spectroscopy in sedimentary media: results of Monte Carlo simulations Radiation Measurements 46 2011 190 195
    • (2011) Radiation Measurements , vol.46 , pp. 190-195
    • Guérin, G.1    Mercier, N.2
  • 21
    • 84863783564 scopus 로고    scopus 로고
    • Dose rate conversion factors: Update
    • G. Guérin, N. Mercier, and G. Adamiec Dose rate conversion factors: update Ancient TL 29 1 2011 5 8
    • (2011) Ancient TL , vol.29 , Issue.1 , pp. 5-8
    • Guérin, G.1    Mercier, N.2    Adamiec, G.3
  • 22
    • 56949091058 scopus 로고    scopus 로고
    • Performance of GEANT4 in dosimetry applications: Calculation of X-ray spectra and kerma-to-dose equivalent conversion coefficients
    • C.C. Guimarães, Maurício Moralles, and Emico Okuno Performance of GEANT4 in dosimetry applications: calculation of X-ray spectra and kerma-to-dose equivalent conversion coefficients Radiation Measurements 43 2008 1525 1531
    • (2008) Radiation Measurements , vol.43 , pp. 1525-1531
    • Guimarães, C.C.1    Moralles, M.2    Okuno, E.3
  • 23
    • 79151484807 scopus 로고    scopus 로고
    • The Clermont radiometric reference rocks: A convenient tool for dosimetric purposes
    • D. Miallier, G. Guérin, N. Mercier, T. Pilleyre, and S. Sanzelle The Clermont radiometric reference rocks: a convenient tool for dosimetric purposes Ancient TL 27 2009 37 44
    • (2009) Ancient TL , vol.27 , pp. 37-44
    • Miallier, D.1    Guérin, G.2    Mercier, N.3    Pilleyre, T.4    Sanzelle, S.5
  • 24
    • 40649114977 scopus 로고    scopus 로고
    • On the dose rate estimate of carbonate-rich sediments for trapped charge dating
    • R.P. Nathan, and B. Mauz On the dose rate estimate of carbonate-rich sediments for trapped charge dating Radiation Measurements 43 2008 14 25
    • (2008) Radiation Measurements , vol.43 , pp. 14-25
    • Nathan, R.P.1    Mauz, B.2
  • 28
    • 84985657451 scopus 로고
    • Thermoluminescence dating using fine grains from pottery
    • D.W. Zimmerman Thermoluminescence dating using fine grains from pottery Archaeometry 13 1971 29 52
    • (1971) Archaeometry , vol.13 , pp. 29-52
    • Zimmerman, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.