메뉴 건너뛰기




Volumn 24, Issue 9, 2012, Pages 699-705

Considerations of noise and measurement reproducibility of circular dichroism measurements using Na[Co III(EDDS)]

Author keywords

calibration; circular dichroism; errors; spectroscopy; standards

Indexed keywords

COBALT; ETHYLENE; ETHYLENE DIAMINE DISUCCINATE; SODIUM; UNCLASSIFIED DRUG;

EID: 84865656086     PISSN: 08990042     EISSN: 1520636X     Source Type: Journal    
DOI: 10.1002/chir.22005     Document Type: Conference Paper
Times cited : (2)

References (18)
  • 1
    • 84943853882 scopus 로고
    • The electronic spectra, optical rotatory power and absolute configuration of metal complexes the dextro-tris (ethylenediamine)cobalt (III) ion
    • McCaffery AJ, Mason SF,. The electronic spectra, optical rotatory power and absolute configuration of metal complexes the dextro-tris (ethylenediamine)cobalt (III) ion. Mol. Phys. 1963; 6: 359-371.
    • (1963) Mol. Phys. , vol.6 , pp. 359-371
    • McCaffery, A.J.1    Mason, S.F.2
  • 2
    • 0014515801 scopus 로고
    • A computerized calibration of the circular dichrometer
    • Cassim JY, Yang JT,. A computerized calibration of the circular dichrometer. Biochemistry 1969; 8: 1947-1951.
    • (1969) Biochemistry , vol.8 , pp. 1947-1951
    • Cassim, J.Y.1    Yang, J.T.2
  • 3
    • 24344473125 scopus 로고
    • Suggested preliminary standards for calibration of optical rotatory dispersion and circular dichroism instruments
    • DeTar DF,. Suggested preliminary standards for calibration of optical rotatory dispersion and circular dichroism instruments. Anal Chem 1969; 41: 1406-1408.
    • (1969) Anal Chem , vol.41 , pp. 1406-1408
    • Detar, D.F.1
  • 4
    • 24344471426 scopus 로고
    • Circular dichrometer calibration by Kramers-Kroenig transform methods
    • Krueger WC, Pschigoda LM,. Circular dichrometer calibration by Kramers-Kroenig transform methods. Anal Chem 1971; 43: 675-677.
    • (1971) Anal Chem , vol.43 , pp. 675-677
    • Krueger, W.C.1    Pschigoda, L.M.2
  • 5
    • 0016529701 scopus 로고
    • D-Pantolactone as a circular dichromism (CD) calibration
    • Konno T, Meguro H, Tuzimura K,. d-Pantolactone as a circular dichromism (CD) calibration. Anal Biochem 1975; 67: 226-232.
    • (1975) Anal Biochem , vol.67 , pp. 226-232
    • Konno, T.1    Meguro, H.2    Tuzimura, K.3
  • 6
    • 49349136843 scopus 로고
    • On the problem of obtaining accurate circular dichroism. Calibration of circular dichroism spectrometers
    • Davidsson Å, Norden B,. On the problem of obtaining accurate circular dichroism. Calibration of circular dichroism spectrometers. Spectrochim Acta A 1976; 32: 717-722.
    • (1976) Spectrochim Acta A , vol.32 , pp. 717-722
    • Davidsson, Ã.1    Norden, B.2
  • 7
    • 0012432914 scopus 로고
    • A critical-study on circular-dichroism measurement in longer side of visible region
    • Konno T, Meguro H, Murakami T, Hatano M,. A critical-study on circular-dichroism measurement in longer side of visible region. Chemistry Letters 1981; 7: 953-956.
    • (1981) Chemistry Letters , vol.7 , pp. 953-956
    • Konno, T.1    Meguro, H.2    Murakami, T.3    Hatano, M.4
  • 8
    • 84998283298 scopus 로고
    • A new standard substance for calibration of circular dichroism: Ammonium d-10-camphorsulfonate
    • Takakuwa T, Konno T, Meguro H,. A new standard substance for calibration of circular dichroism: ammonium d-10-camphorsulfonate. Anal Sci 1985; 1: 215-218.
    • (1985) Anal Sci , vol.1 , pp. 215-218
    • Takakuwa, T.1    Konno, T.2    Meguro, H.3
  • 10
    • 78349236535 scopus 로고    scopus 로고
    • Evaluation of instrumental errors built in circular dichroism spectrometers
    • Castiglioni E, Albertini P, Abbate S,. Evaluation of instrumental errors built in circular dichroism spectrometers. Chirality 2010; 22: E142-E148.
    • (2010) Chirality , vol.22
    • Castiglioni, E.1    Albertini, P.2    Abbate, S.3
  • 12
    • 0348147599 scopus 로고    scopus 로고
    • Calibration and standardisation of synchrotron radiation circular dichroism and conventional circular dichroism spectrophotometers
    • Miles AJ, Wien F, Lees JG, Rodger A, Janes RW, Wallace BA,. Calibration and standardisation of synchrotron radiation circular dichroism and conventional circular dichroism spectrophotometers. Spectroscopy 2003; 17: 653-661. (Pubitemid 38010422)
    • (2003) Spectroscopy , vol.17 , Issue.4 , pp. 653-661
    • Miles, A.J.1    Wien, F.2    Lees, J.G.3    Rodger, A.4    Janes, R.W.5    Wallace, B.A.6
  • 14
    • 0017396393 scopus 로고
    • A critical study of the measurement and calibration of circular dichroism
    • Tuzimura K, Konno T, Meguro H, Hatano M, Murakami T, Kashiwabara K, Saito K, Kondo Y, Suzuki TM,. A critical study of the measurement and calibration of circular dichroism. Anal Biochem 1977; 81: 167-174. (Pubitemid 8141278)
    • (1977) Analytical Biochemistry , vol.81 , Issue.1 , pp. 167-174
    • Tuzimura, K.1    Konno, T.2    Meguro, H.3
  • 17
    • 0020184861 scopus 로고
    • Experimental errors and their effect on analyzing circular dichroism spectra of proteins
    • Hennessey Jr JP, Johnson Jr WC,. Experimental errors and their effect on analyzing circular dichroism spectra of proteins. Anal Biochem 1982; 125: 177-188.
    • (1982) Anal Biochem , vol.125 , pp. 177-188
    • Hennessey, Jr.J.P.1    Johnson, Jr.W.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.