메뉴 건너뛰기




Volumn 5, Issue 1, 2012, Pages

Interrater and intrarater reliability of photoplethysmography for measuring toe blood pressure and toe-brachial index in people with diabetes mellitus

Author keywords

Ankle brachial index; Diabetes mellitus; Doppler; Peripheral arterial disease; Photoplethysmography; Toe brachial index; Toe pressures

Indexed keywords


EID: 84865618498     PISSN: None     EISSN: 17571146     Source Type: Journal    
DOI: 10.1186/1757-1146-5-13     Document Type: Article
Times cited : (28)

References (23)
  • 1
    • 32044470237 scopus 로고    scopus 로고
    • Does the clinical examination predict lower extremity peripheral arterial disease?
    • 10.1001/jama.295.5.536, 16449619
    • Khan NA, Rahim SA, Anand SS, Simel DL, Panju A. Does the clinical examination predict lower extremity peripheral arterial disease?. JAMA 2006, 295:536-546. 10.1001/jama.295.5.536, 16449619.
    • (2006) JAMA , vol.295 , pp. 536-546
    • Khan, N.A.1    Rahim, S.A.2    Anand, S.S.3    Simel, D.L.4    Panju, A.5
  • 2
    • 0035347255 scopus 로고    scopus 로고
    • Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease
    • 10.1067/mva.2001.108011, 11331846
    • de Graaff JC, Ubbink DT, Legemate DA, de Haan RJ, Jacobs MJ. Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease. J Vasc Surg 2001, 33:1033-1040. 10.1067/mva.2001.108011, 11331846.
    • (2001) J Vasc Surg , vol.33 , pp. 1033-1040
    • de Graaff, J.C.1    Ubbink, D.T.2    Legemate, D.A.3    de Haan, R.J.4    Jacobs, M.J.5
  • 3
    • 0037366488 scopus 로고    scopus 로고
    • Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique
    • 10.1046/j.1445-2197.2003.02582.x, 12608969
    • Ramanathan A, Conaghan PJ, Jenkinson AD, Bishop CR. Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique. ANZ J Surg 2003, 73:105-108. 10.1046/j.1445-2197.2003.02582.x, 12608969.
    • (2003) ANZ J Surg , vol.73 , pp. 105-108
    • Ramanathan, A.1    Conaghan, P.J.2    Jenkinson, A.D.3    Bishop, C.R.4
  • 4
    • 38649112313 scopus 로고    scopus 로고
    • Clinical reliability and utility of skin perfusion pressure measurement in ischemic limbs-comparison with other noninvasive diagnostic methods
    • 10.1016/j.jvs.2007.10.045, 18241755
    • Yamada T, Ohta T, Ishibashi H, Sugimoto I, Iwata H, Takahashi M, Kawanishi J. Clinical reliability and utility of skin perfusion pressure measurement in ischemic limbs-comparison with other noninvasive diagnostic methods. J Vasc Surg 2008, 47:318-323. 10.1016/j.jvs.2007.10.045, 18241755.
    • (2008) J Vasc Surg , vol.47 , pp. 318-323
    • Yamada, T.1    Ohta, T.2    Ishibashi, H.3    Sugimoto, I.4    Iwata, H.5    Takahashi, M.6    Kawanishi, J.7
  • 5
    • 33645831377 scopus 로고    scopus 로고
    • The reliability of the ankle-brachial index in the Atherosclerosis Risk in Communities (ARIC) study and the NHLBI Family Heart Study (FHS)
    • 10.1186/1471-2261-6-7, 1435775, 16504033
    • Weatherley BD, Chambless LE, Heiss G, Catellier DJ, Ellison CR. The reliability of the ankle-brachial index in the Atherosclerosis Risk in Communities (ARIC) study and the NHLBI Family Heart Study (FHS). BMC Cardiovasc Disord 2006, 6:7.. 10.1186/1471-2261-6-7, 1435775, 16504033.
    • (2006) BMC Cardiovasc Disord , vol.6
    • Weatherley, B.D.1    Chambless, L.E.2    Heiss, G.3    Catellier, D.J.4    Ellison, C.R.5
  • 6
    • 0020645876 scopus 로고
    • Monckeberg's sclerosis after sympathetic denervation in diabetic and non-diabetic subjects
    • Goebel FD, Fuessl HS. Monckeberg's sclerosis after sympathetic denervation in diabetic and non-diabetic subjects. Diabetologia 1983, 24:347-350.
    • (1983) Diabetologia , vol.24 , pp. 347-350
    • Goebel, F.D.1    Fuessl, H.S.2
  • 7
    • 0027272654 scopus 로고
    • Assessment of peripheral vascular disease in diabetes. Report and recommendations of an international workshop sponsored by the American Heart Association and the American Diabetes Association 18-20 September 1992, New Orleans, Louisiana
    • Orchard TJ, Strandness DE. Assessment of peripheral vascular disease in diabetes. Report and recommendations of an international workshop sponsored by the American Heart Association and the American Diabetes Association 18-20 September 1992, New Orleans, Louisiana. Diabetes Care 1993, 16:1199-1209.
    • (1993) Diabetes Care , vol.16 , pp. 1199-1209
    • Orchard, T.J.1    Strandness, D.E.2
  • 8
    • 24144448822 scopus 로고    scopus 로고
    • An evaluation of the efficacy of methods used in screening for lower-limb arterial disease in diabetes
    • 10.2337/diacare.28.9.2206, 16123491
    • Williams DT, Harding KG, Price P. An evaluation of the efficacy of methods used in screening for lower-limb arterial disease in diabetes. Diabetes Care 2005, 28:2206-2210. 10.2337/diacare.28.9.2206, 16123491.
    • (2005) Diabetes Care , vol.28 , pp. 2206-2210
    • Williams, D.T.1    Harding, K.G.2    Price, P.3
  • 9
    • 0026503066 scopus 로고
    • Peripheral pulse palpation: an unreliable physical sign
    • 2497570, 1616258
    • Brearley S, Shearman CP, Simms MH. Peripheral pulse palpation: an unreliable physical sign. Ann R Coll Surg Engl 1992, 74:169-171. 2497570, 1616258.
    • (1992) Ann R Coll Surg Engl , vol.74 , pp. 169-171
    • Brearley, S.1    Shearman, C.P.2    Simms, M.H.3
  • 11
    • 35448999310 scopus 로고    scopus 로고
    • Prospective assessment of lower-extremity peripheral arterial disease in diabetic patients using a novel automated optical device
    • 10.1177/0003319707305685, 18024941
    • Alnaeb ME, Crabtree VP, Boutin A, Mikhailidis DP, Seifalian AM, Hamilton G. Prospective assessment of lower-extremity peripheral arterial disease in diabetic patients using a novel automated optical device. Angiology 2007, 58:579-585. 10.1177/0003319707305685, 18024941.
    • (2007) Angiology , vol.58 , pp. 579-585
    • Alnaeb, M.E.1    Crabtree, V.P.2    Boutin, A.3    Mikhailidis, D.P.4    Seifalian, A.M.5    Hamilton, G.6
  • 12
    • 33846373642 scopus 로고    scopus 로고
    • Are ankle and toe brachial indices (ABI-TBI) obtained by a pocket Doppler interchangeable with those obtained by standard laboratory equipment?
    • 10.1097/00152192-200701000-00007, 17228206
    • Bonham PA, Cappuccio M, Hulsey T, Michel Y, Kelechi T, Jenkins C, Robison J. Are ankle and toe brachial indices (ABI-TBI) obtained by a pocket Doppler interchangeable with those obtained by standard laboratory equipment?. J Wound Ostomy Continence Nurs 2007, 34:35-44. 10.1097/00152192-200701000-00007, 17228206.
    • (2007) J Wound Ostomy Continence Nurs , vol.34 , pp. 35-44
    • Bonham, P.A.1    Cappuccio, M.2    Hulsey, T.3    Michel, Y.4    Kelechi, T.5    Jenkins, C.6    Robison, J.7
  • 13
    • 33748691425 scopus 로고    scopus 로고
    • Get the LEAD out: noninvasive assessment for lower extremity arterial disease using ankle brachial index and toe brachial index measurements
    • 10.1097/00152192-200601000-00004, 16444101
    • Bonham PA. Get the LEAD out: noninvasive assessment for lower extremity arterial disease using ankle brachial index and toe brachial index measurements. J Wound Ostomy Continence Nurs 2006, 33:30-41. 10.1097/00152192-200601000-00004, 16444101.
    • (2006) J Wound Ostomy Continence Nurs , vol.33 , pp. 30-41
    • Bonham, P.A.1
  • 14
    • 0034851189 scopus 로고    scopus 로고
    • TBI or not TBI: that is the question. Is it better to measure toe pressure than ankle pressure in diabetic patients?
    • 10.1046/j.1464-5491.2001.00493.x, 11553180
    • Brooks B, Dean R, Patel S, Wu B, Molyneaux L, Yue DK. TBI or not TBI: that is the question. Is it better to measure toe pressure than ankle pressure in diabetic patients?. Diabet Med 2001, 18:528-532. 10.1046/j.1464-5491.2001.00493.x, 11553180.
    • (2001) Diabet Med , vol.18 , pp. 528-532
    • Brooks, B.1    Dean, R.2    Patel, S.3    Wu, B.4    Molyneaux, L.5    Yue, D.K.6
  • 15
    • 78651437420 scopus 로고    scopus 로고
    • The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
    • 10.1186/1757-1146-3-31, 3020155, 21176166
    • Romanos M, Raspovic A, Perrin B. The reliability of toe systolic pressure and the toe brachial index in patients with diabetes. J Foot Ankle Res 2010, 3:31. 10.1186/1757-1146-3-31, 3020155, 21176166.
    • (2010) J Foot Ankle Res , vol.3 , pp. 31
    • Romanos, M.1    Raspovic, A.2    Perrin, B.3
  • 16
    • 69249194745 scopus 로고    scopus 로고
    • Randomized trial of custom orthoses and footwear on foot pain and plantar pressure in diabetic peripheral arterial disease
    • 10.1111/j.1464-5491.2009.02799.x, 19719710
    • Burns J, Wegener C, Begg L, Vicaretti M, Fletcher J. Randomized trial of custom orthoses and footwear on foot pain and plantar pressure in diabetic peripheral arterial disease. Diabet Med 2009, 26:893-899. 10.1111/j.1464-5491.2009.02799.x, 19719710.
    • (2009) Diabet Med , vol.26 , pp. 893-899
    • Burns, J.1    Wegener, C.2    Begg, L.3    Vicaretti, M.4    Fletcher, J.5
  • 17
    • 58149355286 scopus 로고    scopus 로고
    • The Role of Ankle-Brachial Index as a Screening Test for Coronary Artery Disease in the Hispanic Population
    • 10.1097/SMJ.0b013e318189aabc, 19088520
    • Enoch A, Ijeoma A. The Role of Ankle-Brachial Index as a Screening Test for Coronary Artery Disease in the Hispanic Population. South Med J 2008, 101:1117-1120. 10.1097/SMJ.0b013e318189aabc, 19088520.
    • (2008) South Med J , vol.101 , pp. 1117-1120
    • Enoch, A.1    Ijeoma, A.2
  • 18
    • 84866101141 scopus 로고    scopus 로고
    • Upper Saddle River, New Jersey, 3rd edn, Foundations of clinical research: applications to practice
    • Portney LG, Watkins MP, . Foundations of clinical research: applications to practice Pearson/Prentice Hal 2009, Upper Saddle River, New Jersey, 3rd edn, Foundations of clinical research: applications to practice.
    • (2009) Pearson/Prentice Hal
    • Portney, L.G.1    Watkins, M.P.2
  • 20
    • 41149129793 scopus 로고    scopus 로고
    • A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease
    • 10.1016/j.jvs.2007.11.057, 18381141
    • Allen J, Overbeck K, Nath AF, Murray A, Stansby G. A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease. J Vasc Surg 2008, 47:794-802. 10.1016/j.jvs.2007.11.057, 18381141.
    • (2008) J Vasc Surg , vol.47 , pp. 794-802
    • Allen, J.1    Overbeck, K.2    Nath, A.F.3    Murray, A.4    Stansby, G.5
  • 21
    • 0029816493 scopus 로고    scopus 로고
    • Value of toe pulse waves in addition to systolic pressures in the assessment of the severity of peripheral arterial disease and critical limb ischemia
    • 10.1016/S0741-5214(96)70101-5, 8752037
    • Carter SA, Tate RB. Value of toe pulse waves in addition to systolic pressures in the assessment of the severity of peripheral arterial disease and critical limb ischemia. J Vasc Surg 1996, 24:258-265. 10.1016/S0741-5214(96)70101-5, 8752037.
    • (1996) J Vasc Surg , vol.24 , pp. 258-265
    • Carter, S.A.1    Tate, R.B.2
  • 22
    • 0015874682 scopus 로고
    • The relationship of distal systolic pressures to the clinical and angiographic findings in limbs with arterial occlusive disease
    • Lezack JD, Carter SA. The relationship of distal systolic pressures to the clinical and angiographic findings in limbs with arterial occlusive disease. Scand J Clin Lab Invest Suppl 1973, 128:97-101.
    • (1973) Scand J Clin Lab Invest Suppl , vol.128 , pp. 97-101
    • Lezack, J.D.1    Carter, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.